{"product_id":"euchner-ces-a-aea-02b-safety-evaluation-unit-for-two-ces-read-heads","title":"Euchner CES-A-AEA-02B Safety Evaluation Unit for Two CES Read Heads","description":"\u003ch4 class=\"PDq2pG_selectionAnchorContainer\"\u003eDescription\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eEuchner CES-A-AEA-02B is a safety evaluation unit designed to process signals from up to two CES electronic-coded read heads in industrial machine safety applications. It provides monitored relay safety outputs for protective door and access monitoring in machinery and automation systems.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable style=\"width: 99.941%; height: 509.438px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.2032%; height: 19.5938px;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.3779%; height: 19.5938px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.2032%; height: 19.5938px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.3779%; height: 19.5938px;\"\u003eEuchner\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.2032%; height: 19.5938px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.3779%; height: 19.5938px;\"\u003eIndustrial Automation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.2032%; height: 19.5938px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.3779%; height: 19.5938px;\"\u003eCES-A-AEA-02B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.2032%; height: 19.5938px;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.3779%; height: 19.5938px;\"\u003eSafety Evaluation Units \/ Safety Controllers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.2032%; height: 19.5938px;\"\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.3779%; height: 19.5938px;\"\u003eNon-Contact Safety System Evaluation Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.2032%; height: 19.5938px;\"\u003e\u003cstrong\u003eOrder Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.3779%; height: 19.5938px;\"\u003e092560\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.2032%; height: 19.5938px;\"\u003e\u003cstrong\u003eSystem\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.3779%; height: 19.5938px;\"\u003eCES-A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.2032%; height: 19.5938px;\"\u003e\u003cstrong\u003eCoding Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.3779%; height: 19.5938px;\"\u003eUnicode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.2032%; height: 19.5938px;\"\u003e\u003cstrong\u003eNumber of Read Heads\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.3779%; height: 19.5938px;\"\u003e2 maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.2032%; height: 19.5938px;\"\u003e\u003cstrong\u003eSafety Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.3779%; height: 19.5938px;\"\u003e2 redundant relay outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.2032%; height: 19.5938px;\"\u003e\u003cstrong\u003eSafety Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.3779%; height: 19.5938px;\"\u003eCategory 4 \/ PL e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.2032%; height: 19.5938px;\"\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.3779%; height: 19.5938px;\"\u003e21–27 VDC regulated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 32.2032%; height: 39.1875px;\"\u003e\u003cstrong\u003eTypical Current Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.3779%; height: 39.1875px;\"\u003e150 mA with relay energized, excluding monitoring-output loads\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.2032%; height: 19.5938px;\"\u003e\u003cstrong\u003eConnection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.3779%; height: 19.5938px;\"\u003eScrew terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.2032%; height: 19.5938px;\"\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.3779%; height: 19.5938px;\"\u003e35 mm DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.2032%; height: 19.5938px;\"\u003e\u003cstrong\u003eResponse Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.3779%; height: 19.5938px;\"\u003eMax. 290 ms with 2 active actuators\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.2032%; height: 19.5938px;\"\u003e\u003cstrong\u003eHousing Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.3779%; height: 19.5938px;\"\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.2032%; height: 19.5938px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.3779%; height: 19.5938px;\"\u003e 0.25 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About \u003cspan\u003eCES-A-AEA-02B\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003e\u003cmeta charset=\"utf-8\"\u003eThe CES-A-AEA-02B is part of the Euchner CES-A series of electronic safety evaluation units. The unit evaluates signals from coded EUCHNER read heads and actuators to monitor movable machine guards. Its Unicode coding allows up to eight actuators to be taught in, with only the last taught-in actuator being recognized. The unit also provides connections for a start button, feedback loop, self-test input, diagnostic output, and monitoring outputs.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003eUnicode Evaluation: Detects only previously taught-in coded actuators.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eTwo Read Heads: Supports connection of up to two compatible read heads.\u003c\/li\u003e\n\u003cli\u003eDual Safety Outputs: Provides two redundant relay safety outputs.\u003c\/li\u003e\n\u003cli\u003eCategory 4 \/ PL e: Suitable for high-level machine safety applications according to EN ISO 13849-1.\u003c\/li\u003e\n\u003cli\u003eFeedback Loop: Provides Y1\/Y2 connections for monitoring an external feedback circuit.\u003c\/li\u003e\n\u003cli\u003eDiagnostic Functions: Includes TST and DIA connections for testing and diagnostics.\u003c\/li\u003e\n\u003cli\u003eDIN-Rail Mounting: Designed for mounting on 35 mm DIN rail according to EN IEC 60715.\u003c\/li\u003e\n\u003cli\u003eIP20 Housing: Evaluation unit enclosure is designed for installation inside a protected control cabinet.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"auto\"\u003eThe CES-A-AEA-02B provides reliable safety signal evaluation for machine guarding and industrial safety-control applications.\u003c\/p\u003e\n\u003cp id=\"p-rc_c7b8f4fae39e183e-25\"\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Euchner","offers":[{"title":"Default Title","offer_id":52728757911850,"sku":"CES-A-AEA-02B","price":755.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/OIP_b4945a75-c005-442f-b422-bc7bf7fc3c01.webp?v=1790086569","url":"https:\/\/iqelectro.com\/products\/euchner-ces-a-aea-02b-safety-evaluation-unit-for-two-ces-read-heads","provider":"IQElectro","version":"1.0","type":"link"}