{"product_id":"euchner-ces-a-aea-04b-safety-evaluation-module-24vdc-4-read-heads","title":"Euchner CES-A-AEA-04B Safety Evaluation Module 24VDC 4 Read Heads","description":"\u003ch4 class=\"PDq2pG_selectionAnchorContainer\"\u003eDescription\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp dir=\"ltr\" data-path-to-node=\"19,0,0\"\u003e\u003cmeta charset=\"UTF-8\"\u003e\u003cmeta charset=\"UTF-8\"\u003e\u003cmeta charset=\"UTF-8\"\u003e\u003cmeta charset=\"UTF-8\"\u003e\u003cmeta charset=\"UTF-8\"\u003e\u003cmeta charset=\"UTF-8\"\u003e\u003cmeta charset=\"UTF-8\"\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\" data-path-to-node=\"1\"\u003e\u003cmeta charset=\"UTF-8\"\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\" data-path-to-node=\"1\"\u003e\u003cmeta charset=\"UTF-8\"\u003e\u003cmeta charset=\"UTF-8\"\u003e\u003cmeta charset=\"UTF-8\"\u003e\u003cmeta charset=\"UTF-8\"\u003e\u003cmeta charset=\"UTF-8\"\u003e\u003cmeta charset=\"UTF-8\"\u003e\u003cmeta charset=\"UTF-8\"\u003e\u003cspan\u003eThe Euchner CES-A-AEA-04B is a non-contact safety evaluation module engineered to monitor up to four transponder-coded read heads simultaneously in industrial automation systems.\u003c\/span\u003e\u003cspan\u003e Operating on 24 VDC with a 250 mA operating current,\u003c\/span\u003e\u003cspan\u003e it features two safety outputs rated at 0.\u003c\/span\u003e\u003cspan\u003e3\/6 A and accessible screw terminals for secure cabinet wiring.\u003c\/span\u003e\u003cspan\u003e Its compact DIN-rail mountable housing streamlines multi-guard safety integration across automated production lines.\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003col start=\"2\" dir=\"ltr\" data-path-to-node=\"2\"\u003e\u003c\/ol\u003e\n\u003cp dir=\"ltr\" data-path-to-node=\"19,0,0\"\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\" data-path-to-node=\"19,0,0\"\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cp\u003e\u003cmeta charset=\"UTF-8\"\u003e\u003c\/p\u003e\n\u003ctable data-path-to-node=\"9\" height=\"348\" style=\"width: 84.517045%; height: 249px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 50.590219%;\"\u003e\u003cspan data-path-to-node=\"9,1,0,0\"\u003e\u003cb data-path-to-node=\"9,1,0,0\" data-index-in-node=\"0\"\u003eCondition\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 48.397976%;\"\u003e\u003cspan data-path-to-node=\"9,1,1,0\"\u003eNew\/Never Used Surplus\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 50.590219%;\"\u003e\u003cspan data-path-to-node=\"9,2,0,0\"\u003e\u003cb data-path-to-node=\"9,2,0,0\" data-index-in-node=\"0\"\u003eBrand\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 48.397976%;\"\u003e\u003cspan data-path-to-node=\"9,2,1,0\"\u003eEuchner\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 50.590219%;\"\u003e\u003cspan data-path-to-node=\"9,3,0,0\"\u003e\u003cb data-path-to-node=\"9,3,0,0\" data-index-in-node=\"0\"\u003eCategory\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 48.397976%;\"\u003e\u003cspan data-path-to-node=\"9,3,1,0\"\u003eSafety Systems\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 50.590219%;\"\u003e\u003cspan data-path-to-node=\"9,4,0,0\"\u003e\u003cb data-path-to-node=\"9,4,0,0\" data-index-in-node=\"0\"\u003ePart Number\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 48.397976%;\"\u003e\u003cspan data-path-to-node=\"9,4,1,0\"\u003eCES-A-AEA-04B\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50.590219%;\"\u003e\u003cspan data-path-to-node=\"9,5,0,0\"\u003e\u003cb data-path-to-node=\"9,5,0,0\" data-index-in-node=\"0\"\u003eSubcategory\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 48.397976%;\"\u003e\u003cspan data-path-to-node=\"9,5,1,0\"\u003eSafety Relay\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50.590219%;\"\u003e\u003cspan data-path-to-node=\"9,6,0,0\"\u003e\u003cb data-path-to-node=\"9,6,0,0\" data-index-in-node=\"0\"\u003eSeries\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 48.397976%;\"\u003e\u003cspan data-path-to-node=\"9,6,1,0\"\u003eCES-A Series\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50.590219%;\"\u003e\u003cspan data-path-to-node=\"9,7,0,0\"\u003e\u003cb data-path-to-node=\"9,7,0,0\" data-index-in-node=\"0\"\u003eProduct Type\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 48.397976%;\"\u003e\u003cspan data-path-to-node=\"9,7,1,0\"\u003eEvaluation Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50.590219%;\"\u003e\u003cspan data-path-to-node=\"9,8,0,0\"\u003e\u003cb data-path-to-node=\"9,8,0,0\" data-index-in-node=\"0\"\u003eMonitored Inputs\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 48.397976%;\"\u003e\u003cspan data-path-to-node=\"9,8,1,0\"\u003eUp to 4 Read Heads\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50.590219%;\"\u003e\u003cspan data-path-to-node=\"9,9,0,0\"\u003e\u003cb data-path-to-node=\"9,9,0,0\" data-index-in-node=\"0\"\u003eSafety Outputs\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 48.397976%;\"\u003e\u003cspan data-path-to-node=\"9,9,1,0\"\u003e2 Outputs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50.590219%;\"\u003e\u003cspan data-path-to-node=\"9,10,0,0\"\u003e\u003cb data-path-to-node=\"9,10,0,0\" data-index-in-node=\"0\"\u003eOutput Current Rating\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 48.397976%;\"\u003e\u003cspan data-path-to-node=\"9,10,1,0\"\u003e0.3 \/ 6 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50.590219%;\"\u003e\u003cspan data-path-to-node=\"9,11,0,0\"\u003e\u003cb data-path-to-node=\"9,11,0,0\" data-index-in-node=\"0\"\u003eRated Operating Voltage\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 48.397976%;\"\u003e\u003cspan data-path-to-node=\"9,11,1,0\"\u003e24 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50.590219%;\"\u003e\u003cspan data-path-to-node=\"9,12,0,0\"\u003e\u003cb data-path-to-node=\"9,12,0,0\" data-index-in-node=\"0\"\u003eOperating Current\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 48.397976%;\"\u003e\u003cspan data-path-to-node=\"9,12,1,0\"\u003e250 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50.590219%;\"\u003e\u003cspan data-path-to-node=\"9,13,0,0\"\u003e\u003cb data-path-to-node=\"9,13,0,0\" data-index-in-node=\"0\"\u003eElectrical Connection\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 48.397976%;\"\u003e\u003cspan data-path-to-node=\"9,13,1,0\"\u003eScrew Terminals\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50.590219%;\"\u003e\u003cspan data-path-to-node=\"9,14,0,0\"\u003e\u003cb data-path-to-node=\"9,14,0,0\" data-index-in-node=\"0\"\u003eWeight\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 48.397976%;\"\u003e\u003cspan data-path-to-node=\"9,14,1,0\"\u003e0.45 kgs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About \u003cspan data-sheets-root=\"1\"\u003eCES-A-AEA-04B\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp dir=\"ltr\" data-path-to-node=\"19,1,0\"\u003e\u003cmeta charset=\"UTF-8\"\u003e\u003cmeta charset=\"UTF-8\"\u003e\u003cmeta charset=\"UTF-8\"\u003e\u003cmeta charset=\"UTF-8\"\u003e\u003cmeta charset=\"UTF-8\"\u003e\u003cmeta charset=\"UTF-8\"\u003e\u003cmeta charset=\"UTF-8\"\u003e\u003cmeta charset=\"UTF-8\"\u003e\u003cmeta charset=\"UTF-8\"\u003e\u003cmeta charset=\"UTF-8\"\u003e\u003cmeta charset=\"UTF-8\"\u003e\u003cmeta charset=\"UTF-8\"\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\" data-path-to-node=\"3\"\u003e\u003cmeta charset=\"UTF-8\"\u003e\u003cmeta charset=\"UTF-8\"\u003e\u003cmeta charset=\"UTF-8\"\u003e\u003cspan\u003eThe Euchner CES-A-AEA-04B is a centralized safety evaluation unit from the CES-A series built for high-integrity machine safeguarding.\u003c\/span\u003e\u003cspan\u003e Its durable thermoplastic enclosure protects internal electronic evaluation circuitry and switching relays against vibration and electrical interference inside control cabinets.\u003c\/span\u003e\u003cspan\u003e Designed for compatibility with up to four Euchner CES read heads and coded actuators,\u003c\/span\u003e\u003cspan\u003e it consolidates multiple guard doors into a single safety control module to reduce panel footprint and wiring complexity.\u003c\/span\u003e\u003cspan\u003e By integrating dual safety outputs rated for 0.\u003c\/span\u003e\u003cspan\u003e3 A and 6 A switching capacities alongside diagnostic indicators,\u003c\/span\u003e\u003cspan\u003e the unit ensures rapid fault detection and dependable circuit interruption when any monitored protective guard opens.\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003cstrong\u003e:\u003c\/strong\u003e\u003cspan\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cmeta charset=\"UTF-8\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cmeta charset=\"UTF-8\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cmeta charset=\"UTF-8\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cmeta charset=\"UTF-8\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cmeta charset=\"UTF-8\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cmeta charset=\"UTF-8\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cmeta charset=\"UTF-8\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cmeta charset=\"UTF-8\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cmeta charset=\"UTF-8\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cmeta charset=\"UTF-8\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cmeta charset=\"UTF-8\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cmeta charset=\"UTF-8\"\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp dir=\"ltr\" data-path-to-node=\"5,0,0\"\u003e\u003cspan\u003eMulti-Read Head Evaluation:\u003c\/span\u003e\u003cspan\u003e Monitors up to 4 transponder-coded safety read heads simultaneously from a single evaluation module.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp dir=\"ltr\" data-path-to-node=\"5,1,0\"\u003e\u003cspan\u003eDual Safety Outputs:\u003c\/span\u003e\u003cspan\u003e Equipped with 2 safety outputs rated at 0.\u003c\/span\u003e\u003cspan\u003e3 A \/ 6 A for flexible load switching across safety control circuits.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp dir=\"ltr\" data-path-to-node=\"5,2,0\"\u003e\u003cspan\u003e24 VDC Control Supply:\u003c\/span\u003e\u003cspan\u003e Operates on a standard 24 VDC supply with a 250 mA current draw for seamless panel compatibility.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp dir=\"ltr\" data-path-to-node=\"5,3,0\"\u003e\u003cspan\u003eScrew Terminal Connections:\u003c\/span\u003e\u003cspan\u003e Features accessible screw terminals for reliable,\u003c\/span\u003e\u003cspan\u003e vibration-resistant field wiring installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp dir=\"ltr\" data-path-to-node=\"5,4,0\"\u003e\u003cspan\u003eSpace-Saving Integration:\u003c\/span\u003e\u003cspan\u003e Consolidates four separate safety guard evaluations into one DIN-rail unit to optimize cabinet space.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp dir=\"ltr\" data-path-to-node=\"5,5,0\"\u003e\u003cspan\u003eTransponder Technology Support:\u003c\/span\u003e\u003cspan\u003e Evaluates high-coding non-contact sensors to prevent tampering and mechanical wear on machine doors.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp dir=\"ltr\" data-path-to-node=\"5,6,0\"\u003e\u003cspan\u003eVisual Status Diagnostics:\u003c\/span\u003e\u003cspan\u003e Onboard LED indicators display power status,\u003c\/span\u003e\u003cspan\u003e read head states,\u003c\/span\u003e\u003cspan\u003e and fault conditions for rapid troubleshooting.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"ltr\" data-path-to-node=\"5,6,0\"\u003e\u003cspan\u003e\u003c\/span\u003e\u003cspan\u003eThe Euchner CES-A-AEA-04B delivers the reliability and precision required for multi-guard non-contact safety evaluation and industrial machine protection.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003c\/span\u003e\u003cspan class=\"citation-409 citation-end-409\"\u003e\u003csup class=\"superscript\" data-turn-source-index=\"15\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp id=\"p-rc_c7b8f4fae39e183e-25\"\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Euchner","offers":[{"title":"Default Title","offer_id":53649666441514,"sku":"CES-A-AEA-04B","price":199.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/s-l1600_fce6f59c-f80b-4a37-80d6-b3775919c754.png?v=1795016943","url":"https:\/\/iqelectro.com\/products\/euchner-ces-a-aea-04b-safety-evaluation-module-24vdc-4-read-heads","provider":"IQElectro","version":"1.0","type":"link"}