{"product_id":"euchner-ces-az-ues-02b-ces-safety-evaluation-module-with-2-read-head-inputs","title":"Euchner CES-AZ-UES-02B CES Safety Evaluation Module with 2 Read Head Inputs","description":"\u003ch4 class=\"PDq2pG_selectionAnchorContainer\"\u003eDescription\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003eThe Euchner CES-AZ-UES-02B is a safety evaluation module for CES-AZ electronic coding safety switches. It supports connection of up to two read heads and provides two monitored relay safety contacts for integration into machine safety circuits. The module operates at 24 VDC and mounts on a TH 35 DIN rail.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable style=\"width: 77.3597%; height: 385.055px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5972px;\"\u003e\n\u003ctd style=\"width: 33.8884%; height: 19.5972px;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.6734%; height: 19.5972px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5972px;\"\u003e\n\u003ctd style=\"width: 33.8884%; height: 19.5972px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.6734%; height: 19.5972px;\"\u003eEuchner\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5972px;\"\u003e\n\u003ctd style=\"width: 33.8884%; height: 19.5972px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.6734%; height: 19.5972px;\"\u003eSmart Switches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5972px;\"\u003e\n\u003ctd style=\"width: 33.8884%; height: 19.5972px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.6734%; height: 19.5972px;\"\u003eCES-AZ-UES-02B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5972px;\"\u003e\n\u003ctd style=\"width: 33.8884%; height: 19.5972px;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.6734%; height: 19.5972px;\"\u003eSafety Switches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5972px;\"\u003e\n\u003ctd style=\"width: 33.8884%; height: 19.5972px;\"\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.6734%; height: 19.5972px;\"\u003eCES-AZ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5972px;\"\u003e\n\u003ctd style=\"width: 33.8884%; height: 19.5972px;\"\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.6734%; height: 19.5972px;\"\u003eSafety Evaluation Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5972px;\"\u003e\n\u003ctd style=\"width: 33.8884%; height: 19.5972px;\"\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.6734%; height: 19.5972px;\"\u003e21–27 VDC, 24 VDC Nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5972px;\"\u003e\n\u003ctd style=\"width: 33.8884%; height: 19.5972px;\"\u003e\u003cstrong\u003eSafety Contacts\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.6734%; height: 19.5972px;\"\u003e2 Relay Contacts, Internally Monitored\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5972px;\"\u003e\n\u003ctd style=\"width: 33.8884%; height: 19.5972px;\"\u003e\u003cstrong\u003eSwitching Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.6734%; height: 19.5972px;\"\u003eMax. 20 mA for Monitoring Outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1944px;\"\u003e\n\u003ctd style=\"width: 33.8884%; height: 39.1944px;\"\u003e\u003cstrong\u003eRated Insulation Voltage Ui\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.6734%; height: 39.1944px;\"\u003e250 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5972px;\"\u003e\n\u003ctd style=\"width: 33.8884%; height: 19.5972px;\"\u003e\u003cstrong\u003eProtection Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.6734%; height: 19.5972px;\"\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1944px;\"\u003e\n\u003ctd style=\"width: 33.8884%; height: 39.1944px;\"\u003e\u003cstrong\u003eAmbient Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.6734%; height: 39.1944px;\"\u003e-20 to +55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5972px;\"\u003e\n\u003ctd style=\"width: 33.8884%; height: 19.5972px;\"\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.6734%; height: 19.5972px;\"\u003e-25 to +70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 32.3056px;\"\u003e\n\u003ctd style=\"width: 33.8884%; height: 32.3056px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.6734%; height: 32.3056px;\"\u003e3.00 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eInformation About \u003cspan\u003eCES-AZ-UES-02B\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003e\u003cmeta charset=\"utf-8\"\u003eThe CES-AZ-UES-02B is part of the Euchner CES safety system and is designed to evaluate coded actuator signals from compatible read heads. Its Multicode configuration allows up to two read heads to be connected to a single evaluation unit. The module provides diagnostic and door-monitoring semiconductor outputs together with floating relay contacts for safety circuits. Internal monitoring of the relay contacts supports reliable evaluation of the connected safety devices.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003eSafety Evaluation Module: Processes signals from compatible CES-AZ coded safety switch read heads.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eRead Head Capacity: Supports connection of up to two read heads to one evaluation unit.\u003c\/li\u003e\n\u003cli\u003eMulticode Technology: Provides coded actuator evaluation for compatible CES-AZ safety systems.\u003c\/li\u003e\n\u003cli\u003eSafety Contacts: Includes two internally monitored relay safety contacts for safety circuit integration.\u003c\/li\u003e\n\u003cli\u003eMonitoring Outputs: Provides DIA, O1, and O2 semiconductor outputs for diagnostics and door monitoring.\u003c\/li\u003e\n\u003cli\u003eOperating Voltage: Designed for regulated 21–27 VDC operation with 24 VDC nominal supply.\u003c\/li\u003e\n\u003cli\u003eDIN Rail Mounting: Installs on TH 35 mounting rail according to EN IEC 60715.\u003c\/li\u003e\n\u003cli\u003eProtection Rating: IP20 housing protection for installation inside suitable control enclosures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"auto\"\u003eThe CES-AZ-UES-02B delivers the reliability and precision required for machine safety evaluation and coded guard monitoring applications.\u003c\/p\u003e\n\u003cp id=\"p-rc_c7b8f4fae39e183e-25\"\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Euchner","offers":[{"title":"Default Title","offer_id":52741340234026,"sku":"CES-AZ-UES-02B","price":645.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/ast_736322_xl.png?v=1790261771","url":"https:\/\/iqelectro.com\/products\/euchner-ces-az-ues-02b-ces-safety-evaluation-module-with-2-read-head-inputs","provider":"IQElectro","version":"1.0","type":"link"}