{"product_id":"festo-cjm-5-2-1-2-fh-bistable-pneumatic-solenoid-directional-control-valve","title":"Festo CJM-5\/2-1\/2-FH Bistable Pneumatic Solenoid Directional Control Valve","description":"\u003ch4 class=\"PDq2pG_selectionAnchorContainer\"\u003eDescription\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe Festo CJM-5\/2-1\/2-FH is an electrically actuated pneumatic directional control valve designed to regulate compressed-air flow in industrial automation systems. This bistable 5\/2-way valve uses pilot actuation to switch between two positions, directing airflow to operate pneumatic cylinders and other actuators.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable style=\"width: 100.029%; height: 627.2px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 35.0781%;\"\u003e\u003cstrong\u003e\u003cspan\u003eCondition\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.6022%;\"\u003e\u003cspan\u003eNew\/Never Used Surplus\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 35.0781%;\"\u003e\u003cstrong\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.6022%;\"\u003e\u003cspan\u003eFesto\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 35.0781%;\"\u003e\u003cstrong\u003e\u003cspan\u003eCategory\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.6022%;\"\u003e\u003cspan\u003ePneumatic Components\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 35.0781%;\"\u003e\u003cstrong\u003e\u003cspan\u003ePart Number\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.6022%;\"\u003e\u003cspan\u003eCJM-5\/2-1\/2-FH\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 35.0781%;\"\u003e\u003cstrong\u003e\u003cspan\u003eSubcategory\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.6022%;\"\u003e\u003cspan\u003ePneumatic Solenoid Valves\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 35.0781%;\"\u003e\u003cstrong\u003e\u003cspan\u003eManufacturer Part Number\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.6022%;\"\u003e\u003cspan\u003e6228\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 35.0781%;\"\u003e\u003cstrong\u003e\u003cspan\u003eProduct Family\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.6022%;\"\u003e\u003cspan\u003eCAS cassette valve\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 35.0781%;\"\u003e\u003cstrong\u003e\u003cspan\u003eValve Type\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.6022%;\"\u003e\u003cspan\u003eDirectional control solenoid valve\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 35.0781%;\"\u003e\u003cstrong\u003e\u003cspan\u003eValve Function\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.6022%;\"\u003e\u003cspan\u003e5\/2-way, bistable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 35.0781%;\"\u003e\u003cstrong\u003e\u003cspan\u003eActuation Type\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.6022%;\"\u003e\u003cspan\u003eElectrical\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 35.0781%;\"\u003e\u003cstrong\u003e\u003cspan\u003ePilot Type\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.6022%;\"\u003e\u003cspan\u003ePilot-operated\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 35.0781%;\"\u003e\u003cstrong\u003e\u003cspan\u003eOperating Pressure\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.6022%;\"\u003e\u003cspan\u003e1.5–8 bar\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 35.0781%;\"\u003e\u003cstrong\u003e\u003cspan\u003ePneumatic Connections\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.6022%;\"\u003e\u003cspan\u003eSub-base connections, ports 1–5\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 35.0781%;\"\u003e\u003cstrong\u003e\u003cspan\u003eNominal Flow Rate\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.6022%;\"\u003e\u003cspan\u003eNot verified for this exact variant\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 35.0781%; height: 19.6px;\"\u003e\u003cstrong\u003e\u003cspan\u003eDigital Inputs\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.6022%; height: 19.6px;\"\u003e\u003cspan\u003e14\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 35.0781%; height: 19.6px;\"\u003e\u003cstrong\u003e\u003cspan\u003eDigital Outputs\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.6022%; height: 19.6px;\"\u003e\u003cspan\u003e5 logic outputs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 35.0781%; height: 19.6px;\"\u003e\u003cstrong\u003e\u003cspan\u003eDisplay\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.6022%; height: 19.6px;\"\u003e\u003cspan\u003eSeven-segment diagnostic display\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 35.0781%; height: 19.6px;\"\u003e\u003cstrong\u003e\u003cspan\u003eMounting\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.6022%; height: 19.6px;\"\u003e\u003cspan\u003eMounting plate, bolted\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 35.0781%; height: 19.6px;\"\u003e\u003cstrong\u003e\u003cspan\u003eProtection Rating\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.6022%; height: 19.6px;\"\u003e\u003cspan\u003eIP10 \/ IP20, depending on the specified protection area\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 35.0781%; height: 19.6px;\"\u003e\u003cstrong\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.6022%; height: 19.6px;\"\u003e\u003cspan\u003e0.99 lb\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About CJM-5\/2-1\/2-FH\u003c\/h4\u003e\n\u003cp\u003eThe CJM-5\/2-1\/2-FH belongs to Festo’s classic CAS cassette valve product family and carries manufacturer part number 6228. It features a bistable spool configuration, meaning the valve retains its last switching position after the electrical actuation signal is removed. The valve operates with a pneumatic supply pressure of 1.5 to 8 bar and uses sub-base connections for all five pneumatic ports. It is supplied with a plug socket and manual override, while the mounting sub-base is not included.\u003c\/p\u003e\n\u003ch4 dir=\"auto\" data-start=\"456\" data-end=\"1011\" class=\"PDq2pG_selectionAnchorContainer\"\u003eKey Features:\u003cspan\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003e5\/2-Way \u003c\/span\u003e\u003cspan\u003eValve \u003c\/span\u003e\u003cspan\u003eFunction: \u003c\/span\u003e\u003cspan\u003eDirects \u003c\/span\u003e\u003cspan\u003ecompressed \u003c\/span\u003e\u003cspan\u003eair \u003c\/span\u003e\u003cspan\u003ethrough \u003c\/span\u003e\u003cspan\u003efive \u003c\/span\u003e\u003cspan\u003eports \u003c\/span\u003e\u003cspan\u003eand \u003c\/span\u003e\u003cspan\u003etwo \u003c\/span\u003e\u003cspan\u003eswitching \u003c\/span\u003e\u003cspan\u003epositions.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eBistable \u003c\/span\u003e\u003cspan\u003eOperation: \u003c\/span\u003e\u003cspan\u003eMaintains \u003c\/span\u003e\u003cspan\u003eits \u003c\/span\u003e\u003cspan\u003eselected \u003c\/span\u003e\u003cspan\u003eposition \u003c\/span\u003e\u003cspan\u003eafter \u003c\/span\u003e\u003cspan\u003ethe \u003c\/span\u003e\u003cspan\u003eswitching \u003c\/span\u003e\u003cspan\u003esignal \u003c\/span\u003e\u003cspan\u003eis \u003c\/span\u003e\u003cspan\u003eremoved.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eElectrical \u003c\/span\u003e\u003cspan\u003eActuation: \u003c\/span\u003e\u003cspan\u003eSupports \u003c\/span\u003e\u003cspan\u003eautomated \u003c\/span\u003e\u003cspan\u003eswitching \u003c\/span\u003e\u003cspan\u003ethrough \u003c\/span\u003e\u003cspan\u003ean \u003c\/span\u003e\u003cspan\u003eelectrical \u003c\/span\u003e\u003cspan\u003econtrol \u003c\/span\u003e\u003cspan\u003esignal.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003ePilot-Operated \u003c\/span\u003e\u003cspan\u003eDesign: \u003c\/span\u003e\u003cspan\u003eUses \u003c\/span\u003e\u003cspan\u003epilot \u003c\/span\u003e\u003cspan\u003epressure \u003c\/span\u003e\u003cspan\u003eto \u003c\/span\u003e\u003cspan\u003eactuate \u003c\/span\u003e\u003cspan\u003ethe \u003c\/span\u003e\u003cspan\u003emain \u003c\/span\u003e\u003cspan\u003evalve \u003c\/span\u003e\u003cspan\u003emechanism.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eOperating \u003c\/span\u003e\u003cspan\u003ePressure \u003c\/span\u003e\u003cspan\u003eRange: \u003c\/span\u003e\u003cspan\u003eSupports \u003c\/span\u003e\u003cspan\u003epneumatic \u003c\/span\u003e\u003cspan\u003eoperation \u003c\/span\u003e\u003cspan\u003efrom \u003c\/span\u003e\u003cspan\u003e1.5 \u003c\/span\u003e\u003cspan\u003eto \u003c\/span\u003e\u003cspan\u003e8 \u003c\/span\u003e\u003cspan\u003ebar.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eSub-Base \u003c\/span\u003e\u003cspan\u003eMounting: \u003c\/span\u003e\u003cspan\u003eConnects \u003c\/span\u003e\u003cspan\u003ethrough \u003c\/span\u003e\u003cspan\u003ea \u003c\/span\u003e\u003cspan\u003ecompatible \u003c\/span\u003e\u003cspan\u003emounting \u003c\/span\u003e\u003cspan\u003ebase \u003c\/span\u003e\u003cspan\u003erather \u003c\/span\u003e\u003cspan\u003ethan \u003c\/span\u003e\u003cspan\u003edirect \u003c\/span\u003e\u003cspan\u003ethreaded \u003c\/span\u003e\u003cspan\u003eworking \u003c\/span\u003e\u003cspan\u003eports.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eManual \u003c\/span\u003e\u003cspan\u003eOverride: \u003c\/span\u003e\u003cspan\u003eAllows \u003c\/span\u003e\u003cspan\u003emanual \u003c\/span\u003e\u003cspan\u003eswitching \u003c\/span\u003e\u003cspan\u003efor \u003c\/span\u003e\u003cspan\u003esetup \u003c\/span\u003e\u003cspan\u003eand \u003c\/span\u003e\u003cspan\u003emaintenance.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003ePlug \u003c\/span\u003e\u003cspan\u003eSocket \u003c\/span\u003e\u003cspan\u003eIncluded: \u003c\/span\u003e\u003cspan\u003eProvides \u003c\/span\u003e\u003cspan\u003ean \u003c\/span\u003e\u003cspan\u003eelectrical \u003c\/span\u003e\u003cspan\u003econnection \u003c\/span\u003e\u003cspan\u003eaccessory; \u003c\/span\u003e\u003cspan\u003ethe \u003c\/span\u003e\u003cspan\u003emounting \u003c\/span\u003e\u003cspan\u003esub-base \u003c\/span\u003e\u003cspan\u003emust \u003c\/span\u003e\u003cspan\u003ebe \u003c\/span\u003e\u003cspan\u003epurchased \u003c\/span\u003e\u003cspan\u003eseparately.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cspan\u003eCJM-5\/2-1\/2-FH \u003c\/span\u003e\u003cspan\u003eprovides \u003c\/span\u003e\u003cspan\u003edependable \u003c\/span\u003e\u003cspan\u003edirectional \u003c\/span\u003e\u003cspan\u003eair \u003c\/span\u003e\u003cspan\u003econtrol \u003c\/span\u003e\u003cspan\u003efor \u003c\/span\u003e\u003cspan\u003epneumatic \u003c\/span\u003e\u003cspan\u003ecylinders, \u003c\/span\u003e\u003cspan\u003eautomated \u003c\/span\u003e\u003cspan\u003eproduction \u003c\/span\u003e\u003cspan\u003eequipment, \u003c\/span\u003e\u003cspan\u003epackaging \u003c\/span\u003e\u003cspan\u003emachinery, \u003c\/span\u003e\u003cspan\u003eand \u003c\/span\u003e\u003cspan\u003eindustrial \u003c\/span\u003e\u003cspan\u003ehandling \u003c\/span\u003e\u003cspan\u003esystems.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp id=\"p-rc_c7b8f4fae39e183e-25\"\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":52942428373290,"sku":"CJM-5\/2-1\/2-FH","price":1095.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/OIP_e19b63e3-6ca5-499a-88fb-cffe8ddaa286.webp?v=1792016567","url":"https:\/\/iqelectro.com\/products\/festo-cjm-5-2-1-2-fh-bistable-pneumatic-solenoid-directional-control-valve","provider":"IQElectro","version":"1.0","type":"link"}