{"product_id":"festo-cpv14-ge-dn2-8-devicenet-electrical-interface-module","title":"Festo CPV14-GE-DN2-8 DeviceNet Electrical Interface Module","description":"\u003ch4 class=\"PDq2pG_selectionAnchorContainer\"\u003eDescription\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003eThe Festo CPV14-GE-DN2-8 is an electrical interface module designed for Festo CPV14 pneumatic valve terminals in industrial automation systems. It supports DeviceNet communication and provides connectivity for up to 16 inputs and 8 outputs, or up to 16 valves, depending on the configuration. The interface supports a 24 V DC system and uses a 5-pin M12 connection option for fieldbus communication.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable style=\"width: 70%; height: 686.667px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 52.6389px;\"\u003e\n\u003ctd style=\"width: 35.7179%;\"\u003e\n\u003cp\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 64.0385%;\"\u003e\n\u003cp\u003e\u003cspan\u003eNew\/Never \u003c\/span\u003e\u003cspan\u003eUsed \u003c\/span\u003e\u003cspan\u003eSurplus\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 52.6389px;\"\u003e\n\u003ctd style=\"width: 35.7179%;\"\u003e\n\u003cp\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 64.0385%;\"\u003e\n\u003cp\u003e\u003cspan\u003eFesto\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.7179%;\"\u003e\n\u003cp\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 64.0385%;\"\u003e\n\u003cp\u003e\u003cspan\u003eValves\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.7179%;\"\u003e\n\u003cp\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 64.0385%;\"\u003e\n\u003cp\u003e\u003cspan\u003eCPV14-GE-DN2-8\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.7179%;\"\u003e\n\u003cp\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 64.0385%;\"\u003e\n\u003cp\u003e\u003cspan\u003eValve \u003c\/span\u003e\u003cspan\u003eInterfaces\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.7179%;\"\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 64.0385%;\"\u003e\n\u003cp\u003e\u003cspan\u003e525878\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.7179%;\"\u003e\n\u003cp\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 64.0385%;\"\u003e\n\u003cp\u003e\u003cspan\u003eCPV14\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.7179%;\"\u003e\n\u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 64.0385%;\"\u003e\n\u003cp\u003e\u003cspan\u003ePneumatic \u003c\/span\u003e\u003cspan\u003evalve \u003c\/span\u003e\u003cspan\u003eterminal \u003c\/span\u003e\u003cspan\u003econtrol\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.7179%;\"\u003e\n\u003cp\u003e\u003cstrong\u003eFieldbus Protocol\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 64.0385%;\"\u003e\n\u003cp\u003e\u003cspan\u003eDeviceNet\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.7179%;\"\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Voltage\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 64.0385%;\"\u003e\n\u003cp\u003e\u003cspan\u003e24 \u003c\/span\u003e\u003cspan\u003eV \u003c\/span\u003e\u003cspan\u003eDC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.7179%;\"\u003e\n\u003cp\u003e\u003cstrong\u003eInput Capacity\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 64.0385%;\"\u003e\n\u003cp\u003e\u003cspan\u003eUp \u003c\/span\u003e\u003cspan\u003eto \u003c\/span\u003e\u003cspan\u003e16 \u003c\/span\u003e\u003cspan\u003einputs\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.7179%;\"\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Capacity\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 64.0385%;\"\u003e\n\u003cp\u003e\u003cspan\u003eUp \u003c\/span\u003e\u003cspan\u003eto \u003c\/span\u003e\u003cspan\u003e8 \u003c\/span\u003e\u003cspan\u003eoutputs \u003c\/span\u003e\u003cspan\u003eor \u003c\/span\u003e\u003cspan\u003e16 \u003c\/span\u003e\u003cspan\u003evalves, \u003c\/span\u003e\u003cspan\u003edepending \u003c\/span\u003e\u003cspan\u003eon \u003c\/span\u003e\u003cspan\u003econfiguration\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.7179%;\"\u003e\n\u003cp\u003e\u003cstrong\u003eFieldbus Connector\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 64.0385%;\"\u003e\n\u003cp\u003e\u003cspan\u003eM12 \u003c\/span\u003e\u003cspan\u003e× \u003c\/span\u003e\u003cspan\u003e1, \u003c\/span\u003e\u003cspan\u003e5-pin, \u003c\/span\u003e\u003cspan\u003eA-coded \u003c\/span\u003e\u003cspan\u003eoption\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.7179%;\"\u003e\n\u003cp\u003e\u003cstrong\u003eAlternative Connection Options\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 64.0385%;\"\u003e\n\u003cp\u003e\u003cspan\u003e5-pin \u003c\/span\u003e\u003cspan\u003escrew \u003c\/span\u003e\u003cspan\u003eterminal \u003c\/span\u003e\u003cspan\u003estrip \u003c\/span\u003e\u003cspan\u003eor \u003c\/span\u003e\u003cspan\u003e9-pin \u003c\/span\u003e\u003cspan\u003eSub-D \u003c\/span\u003e\u003cspan\u003esocket, \u003c\/span\u003e\u003cspan\u003edepending \u003c\/span\u003e\u003cspan\u003eon \u003c\/span\u003e\u003cspan\u003econfiguration\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.7179%;\"\u003e\n\u003cp\u003e\u003cstrong\u003eDiagnostics\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 64.0385%;\"\u003e\n\u003cp\u003e\u003cspan\u003eMissing \u003c\/span\u003e\u003cspan\u003emodule, \u003c\/span\u003e\u003cspan\u003eshort \u003c\/span\u003e\u003cspan\u003ecircuit, \u003c\/span\u003e\u003cspan\u003eoverload, \u003c\/span\u003e\u003cspan\u003eand \u003c\/span\u003e\u003cspan\u003eundervoltage \u003c\/span\u003e\u003cspan\u003emonitoring\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.7179%;\"\u003e\n\u003cp\u003e\u003cstrong\u003eConfiguration Support\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 64.0385%;\"\u003e\n\u003cp\u003e\u003cspan\u003eEDS \u003c\/span\u003e\u003cspan\u003efile \u003c\/span\u003e\u003cspan\u003eand \u003c\/span\u003e\u003cspan\u003egraphic \u003c\/span\u003e\u003cspan\u003esymbol\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.7179%;\"\u003e\n\u003cp\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 64.0385%;\"\u003e\n\u003cp\u003e\u003cspan\u003e0.64 \u003c\/span\u003e\u003cspan\u003elb \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eInformation About \u003cspan data-sheets-root=\"1\"\u003eCPV14-GE-DN2-8\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp data-pm-slice=\"1 1 []\"\u003eThe CPV14-GE-DN2-8 belongs to Festo’s CPV14 valve-terminal system and is identified by manufacturer part number 525878. It enables communication between a compatible control system and the connected valve terminal or I\/O modules. Diagnostic functions can monitor conditions such as missing modules, short circuits, overloads, and undervoltage. Configuration support includes an EDS file and a graphic symbol for integration with compatible DeviceNet control systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eElectrical \u003c\/span\u003e\u003cspan\u003eInterface: \u003c\/span\u003e\u003cspan\u003eConnects \u003c\/span\u003e\u003cspan\u003ea \u003c\/span\u003e\u003cspan\u003ecompatible \u003c\/span\u003e\u003cspan\u003econtroller \u003c\/span\u003e\u003cspan\u003eto \u003c\/span\u003e\u003cspan\u003ea \u003c\/span\u003e\u003cspan\u003eFesto \u003c\/span\u003e\u003cspan\u003eCPV14 \u003c\/span\u003e\u003cspan\u003evalve-terminal \u003c\/span\u003e\u003cspan\u003esystem.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eDeviceNet \u003c\/span\u003e\u003cspan\u003eCommunication: \u003c\/span\u003e\u003cspan\u003eSupports \u003c\/span\u003e\u003cspan\u003efieldbus \u003c\/span\u003e\u003cspan\u003ecommunication \u003c\/span\u003e\u003cspan\u003ewith \u003c\/span\u003e\u003cspan\u003ecompatible \u003c\/span\u003e\u003cspan\u003eautomation \u003c\/span\u003e\u003cspan\u003econtrollers.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eInput \u003c\/span\u003e\u003cspan\u003eCapacity: \u003c\/span\u003e\u003cspan\u003eSupports \u003c\/span\u003e\u003cspan\u003eup \u003c\/span\u003e\u003cspan\u003eto \u003c\/span\u003e\u003cspan\u003e16 \u003c\/span\u003e\u003cspan\u003einputs.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eOutput \u003c\/span\u003e\u003cspan\u003eCapacity: \u003c\/span\u003e\u003cspan\u003eSupports \u003c\/span\u003e\u003cspan\u003eup \u003c\/span\u003e\u003cspan\u003eto \u003c\/span\u003e\u003cspan\u003e8 \u003c\/span\u003e\u003cspan\u003eoutputs \u003c\/span\u003e\u003cspan\u003eor \u003c\/span\u003e\u003cspan\u003eup \u003c\/span\u003e\u003cspan\u003eto \u003c\/span\u003e\u003cspan\u003e16 \u003c\/span\u003e\u003cspan\u003evalves, \u003c\/span\u003e\u003cspan\u003edepending \u003c\/span\u003e\u003cspan\u003eon \u003c\/span\u003e\u003cspan\u003econfiguration.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003e24 \u003c\/span\u003e\u003cspan\u003eV \u003c\/span\u003e\u003cspan\u003eDC \u003c\/span\u003e\u003cspan\u003eSystem: \u003c\/span\u003e\u003cspan\u003eDesigned \u003c\/span\u003e\u003cspan\u003efor \u003c\/span\u003e\u003cspan\u003euse \u003c\/span\u003e\u003cspan\u003ein \u003c\/span\u003e\u003cspan\u003ecompatible \u003c\/span\u003e\u003cspan\u003e24 \u003c\/span\u003e\u003cspan\u003eV \u003c\/span\u003e\u003cspan\u003eDC \u003c\/span\u003e\u003cspan\u003econtrol \u003c\/span\u003e\u003cspan\u003einstallations.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eM12 \u003c\/span\u003e\u003cspan\u003eConnection: \u003c\/span\u003e\u003cspan\u003eSupports \u003c\/span\u003e\u003cspan\u003ea \u003c\/span\u003e\u003cspan\u003e5-pin \u003c\/span\u003e\u003cspan\u003eM12 \u003c\/span\u003e\u003cspan\u003efieldbus \u003c\/span\u003e\u003cspan\u003econnector \u003c\/span\u003e\u003cspan\u003eoption.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eDiagnostic \u003c\/span\u003e\u003cspan\u003eFunctions: \u003c\/span\u003e\u003cspan\u003eSupports \u003c\/span\u003e\u003cspan\u003emonitoring \u003c\/span\u003e\u003cspan\u003efor \u003c\/span\u003e\u003cspan\u003emodule \u003c\/span\u003e\u003cspan\u003efaults, \u003c\/span\u003e\u003cspan\u003eshort \u003c\/span\u003e\u003cspan\u003ecircuits, \u003c\/span\u003e\u003cspan\u003eoverloads, \u003c\/span\u003e\u003cspan\u003eand \u003c\/span\u003e\u003cspan\u003eundervoltage.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eConfiguration \u003c\/span\u003e\u003cspan\u003eSupport: \u003c\/span\u003e\u003cspan\u003eProvides \u003c\/span\u003e\u003cspan\u003eEDS-file \u003c\/span\u003e\u003cspan\u003eand \u003c\/span\u003e\u003cspan\u003egraphic-symbol \u003c\/span\u003e\u003cspan\u003esupport \u003c\/span\u003e\u003cspan\u003efor \u003c\/span\u003e\u003cspan\u003esystem \u003c\/span\u003e\u003cspan\u003econfiguration.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cspan\u003eCPV14-GE-DN2-8 \u003c\/span\u003e\u003cspan\u003edelivers \u003c\/span\u003e\u003cspan\u003ethe \u003c\/span\u003e\u003cspan\u003ereliability \u003c\/span\u003e\u003cspan\u003eand \u003c\/span\u003e\u003cspan\u003eprecision \u003c\/span\u003e\u003cspan\u003erequired \u003c\/span\u003e\u003cspan\u003efor \u003c\/span\u003e\u003cspan\u003ecommunication \u003c\/span\u003e\u003cspan\u003eand \u003c\/span\u003e\u003cspan\u003econtrol \u003c\/span\u003e\u003cspan\u003ewithin \u003c\/span\u003e\u003cspan\u003ecompatible \u003c\/span\u003e\u003cspan\u003eFesto \u003c\/span\u003e\u003cspan\u003epneumatic \u003c\/span\u003e\u003cspan\u003eautomation \u003c\/span\u003e\u003cspan\u003esystems.\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp id=\"p-rc_c7b8f4fae39e183e-25\"\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":52988831826218,"sku":"CPV14-GE-DN2-8","price":999.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/s-l1600_2640e425-affb-4528-a89f-efe85deeb33e.webp?v=1792243781","url":"https:\/\/iqelectro.com\/products\/festo-cpv14-ge-dn2-8-devicenet-electrical-interface-module","provider":"IQElectro","version":"1.0","type":"link"}