{"product_id":"fike-02-12728-impulse-valve-operator-for-clean-agent-fire-suppression-systems","title":"Fike 02-12728 Impulse Valve Operator for Clean Agent Fire Suppression Systems","description":"\u003ch4 class=\"PDq2pG_selectionAnchorContainer\" data-end=\"14\" data-start=\"0\"\u003eDescription\u003cspan class=\"PDq2pG_selectionAnchor\" aria-hidden=\"true\"\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp data-end=\"389\" data-start=\"16\"\u003eThe Fike 02-12728 is an Impulse Valve Operator (IVO) designed to actuate compatible Fike clean agent fire suppression containers using either electrical or manual activation. It provides the mechanical force necessary to open the container's impulse valve, ensuring rapid discharge of the extinguishing agent in special hazard fire protection systems.\u003c\/p\u003e\n\u003cp data-end=\"389\" data-start=\"16\"\u003e \u003c\/p\u003e\n\u003cp data-end=\"389\" data-start=\"16\"\u003e \u003c\/p\u003e\n\u003ch4 data-end=\"389\" data-start=\"16\"\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable style=\"width: 90.2174%; height: 245.126px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 31.4274%;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.3293%;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 31.4274%;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.3293%;\"\u003eFike\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 31.4274%;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.3293%;\"\u003eFire Suppression Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 31.4274%;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.3293%;\"\u003e02-12728\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 10px;\"\u003e\n\u003ctd style=\"width: 31.4274%;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.3293%;\"\u003eImpulse Valve Operators\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 31.4274%;\"\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.3293%;\"\u003eImpulse Valve Operator (IVO)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 31.4274%;\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.3293%;\"\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 31.4274%;\"\u003e\u003cstrong\u003eCurrent Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.3293%;\"\u003e0 A standby; 3 A momentary pulse from IRM capacitors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 31.4274%;\"\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.3293%;\"\u003eStainless steel body, brass end cap, stainless steel piston\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 31.4274%;\"\u003e\u003cstrong\u003eElectrical Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.3293%;\"\u003e1\/2 in. NPT conduit connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 31.4274%;\"\u003e\u003cstrong\u003eWire Leads\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.3293%;\"\u003eTwo 20 AWG black wires, 36 in. (914 mm) long\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.4274%;\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.3293%;\"\u003e32°F to 130°F (0°C to 54.4°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.4274%;\"\u003e\u003cstrong\u003eMaximum Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.3293%;\"\u003e93% RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.4274%;\"\u003e\u003cstrong\u003eActivation Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.3293%;\"\u003eElectrical and manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.4274%;\"\u003e\u003cstrong\u003eCompatible Module\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.3293%;\"\u003eFike Impulse Releasing Module (IRM) P\/N 10-2748\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.4274%;\"\u003e\u003cstrong\u003eApprovals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.3293%;\"\u003eUL, ULC, FM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.4274%;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.3293%;\"\u003e2 lb (0.9 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4 data-end=\"411\" data-start=\"391\"\u003eInformation About \u003cspan data-sheets-root=\"1\"\u003e02-12728\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp class=\"PDq2pG_selectionAnchorContainer\" data-end=\"1070\" data-start=\"465\"\u003eThe 02-12728 is a critical component of Fike impulse valve fire suppression systems used to release clean agent extinguishing media during fire events. Constructed with a stainless steel body, brass end cap, and stainless steel piston, it is engineered for durability and dependable operation in demanding environments. The operator is activated by a 24 VDC electrical signal through a compatible Fike Impulse Releasing Module (IRM) or manually by removing the safety cotter pin and pressing the integrated strike button. Following activation, the device can be reset and returned to service, simplifying maintenance and system restoration.\u003c\/p\u003e\n\u003cp data-end=\"1106\" data-start=\"1091\"\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-end=\"2309\" data-start=\"1108\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"2068\" data-start=\"1260\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1873\" data-start=\"1167\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1931\" data-start=\"1190\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1773\" data-start=\"1117\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1818\" data-start=\"1097\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1747\" data-start=\"1099\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1752\" data-start=\"1103\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1756\" data-start=\"1087\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1195\" data-end=\"1821\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1129\" data-end=\"1770\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1183\" data-end=\"1910\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1121\" data-end=\"1802\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1797\" data-start=\"1102\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"2192\" data-start=\"1321\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"2020\" data-start=\"1268\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1873\" data-start=\"1155\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1876\" data-start=\"1175\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1759\" data-start=\"1100\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1830\" data-start=\"1129\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"2068\" data-start=\"1308\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1945\" data-start=\"1174\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"2043\" data-start=\"1239\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1810\" data-start=\"1119\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"2023\" data-start=\"1329\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"2116\" data-start=\"1363\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1977\" data-start=\"1296\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"2036\" data-start=\"1360\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"2101\" data-start=\"1179\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"2123\" data-start=\"1129\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1957\" data-start=\"1112\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1003\" data-end=\"1658\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1007\" data-end=\"1642\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1193\" data-end=\"1892\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1135\" data-end=\"1884\"\u003e\n\u003cli data-section-id=\"8cvzsv\" data-start=\"1135\" data-end=\"1216\"\u003eElectrical Actuation: Operates from a compatible 24 VDC Fike releasing circuit.\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"e4gxy6\" data-start=\"1217\" data-end=\"1319\"\u003eManual Activation: Includes a strike button for manual release after removing the safety cotter pin.\u003c\/li\u003e\n\u003cli data-section-id=\"1ox91ae\" data-start=\"1320\" data-end=\"1419\"\u003eDurable Construction: Features a stainless steel body, brass end cap, and stainless steel piston.\u003c\/li\u003e\n\u003cli data-section-id=\"1e7adeo\" data-start=\"1420\" data-end=\"1495\"\u003eResettable Mechanism: Can be reset after operation for continued service.\u003c\/li\u003e\n\u003cli data-section-id=\"a8bwvh\" data-start=\"1496\" data-end=\"1587\"\u003eIRM Compatibility: Designed for use with the Fike Impulse Releasing Module (P\/N 10-2748).\u003c\/li\u003e\n\u003cli data-section-id=\"19yc11t\" data-start=\"1588\" data-end=\"1707\"\u003eSupervised Installation: Supports continuous supervision when used with the Impulse Valve Operator Supervisor (IVOS).\u003c\/li\u003e\n\u003cli data-section-id=\"h5ivak\" data-start=\"1708\" data-end=\"1799\"\u003eIndustrial Wiring: Equipped with a 1\/2-inch NPT conduit connection and 20 AWG wire leads.\u003c\/li\u003e\n\u003cli data-section-id=\"d88xy0\" data-start=\"1800\" data-end=\"1884\"\u003eCertified Performance: UL, ULC, and FM approved for fire suppression applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1886\" data-end=\"2052\"\u003eThe 02-12728 delivers the reliability and precision required for dependable activation of clean agent fire suppression containers in critical fire protection systems.\u003c\/p\u003e","brand":"Fike","offers":[{"title":"Default Title","offer_id":52140519719210,"sku":"02-12728","price":589.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/s-l1600_395e0c74-fe52-46a1-a65b-7f247e7df1e1.webp?v=1785250693","url":"https:\/\/iqelectro.com\/products\/fike-02-12728-impulse-valve-operator-for-clean-agent-fire-suppression-systems","provider":"IQElectro","version":"1.0","type":"link"}