{"product_id":"fike-10-1832-arm-iii-agent-release-module-for-clean-agent-systems","title":"Fike 10-1832 ARM III Agent Release Module for Clean Agent Systems","description":"\u003ch4 class=\"PDq2pG_selectionAnchorContainer\" data-end=\"14\" data-start=\"0\"\u003eDescription\u003cspan class=\"PDq2pG_selectionAnchor\" aria-hidden=\"true\"\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp data-end=\"389\" data-start=\"16\"\u003eThe Fike 10-1832 is an Agent Release Module (ARM III) designed for clean agent fire suppression systems. It serves as the interface between a compatible Fike releasing control panel and the gas cartridge actuator, allowing multiple actuators to be connected in parallel for improved system reliability and supervised release circuit operation.\u003c\/p\u003e\n\u003cp data-end=\"389\" data-start=\"16\"\u003e \u003c\/p\u003e\n\u003cp data-end=\"389\" data-start=\"16\"\u003e \u003c\/p\u003e\n\u003ch4 data-end=\"389\" data-start=\"16\"\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable style=\"width: 90.2174%; height: 303.907px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.0908%; height: 19.5938px;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.6659%; height: 19.5938px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.0908%; height: 19.5938px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.6659%; height: 19.5938px;\"\u003eFike\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.0908%; height: 19.5938px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.6659%; height: 19.5938px;\"\u003eFire Suppression Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.0908%; height: 19.5938px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.6659%; height: 19.5938px;\"\u003e10-1832\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.0908%; height: 19.5938px;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.6659%; height: 19.5938px;\"\u003eAgent Release Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.0908%; height: 19.5938px;\"\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.6659%; height: 19.5938px;\"\u003eAgent Release Module (ARM III)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.0908%; height: 19.5938px;\"\u003e\u003cstrong\u003eCompatible Systems\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.6659%; height: 19.5938px;\"\u003eSHP Pro®, Cheetah® Xi, Cheetah® Xi 50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 10px;\"\u003e\n\u003ctd style=\"width: 36.0908%; height: 10px;\"\u003e\u003cstrong\u003eCompatible Actuator\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.6659%; height: 10px;\"\u003eFike 70-1651 Gas Cartridge Actuator (GCA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.0908%; height: 19.5938px;\"\u003e\u003cstrong\u003eWiring Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.6659%; height: 19.5938px;\"\u003eClass A or Class B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.0908%; height: 19.5938px;\"\u003e\u003cstrong\u003eSupervisory Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.6659%; height: 19.5938px;\"\u003e21 mA (charging), 2 mA (charged) @ 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.0908%; height: 19.5938px;\"\u003e\u003cstrong\u003eActivated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.6659%; height: 19.5938px;\"\u003e8 mA LED active\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.0908%; height: 19.5938px;\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.6659%; height: 19.5938px;\"\u003e32 to 120°F (0 to 49°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.0908%; height: 19.5938px;\"\u003e\u003cstrong\u003eMaximum Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.6659%; height: 19.5938px;\"\u003e93% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.0908%; height: 19.5938px;\"\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.6659%; height: 19.5938px;\"\u003e4 in. square × 2.125 in. deep electrical box\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.0908%; height: 19.5938px;\"\u003e\u003cstrong\u003eApprovals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.6659%; height: 19.5938px;\"\u003eUL Listed, FM Approved\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.0908%; height: 19.5938px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.6659%; height: 19.5938px;\"\u003e0.2 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4 data-end=\"411\" data-start=\"391\"\u003eInformation About \u003cspan data-sheets-root=\"1\"\u003e10-1832\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp class=\"PDq2pG_selectionAnchorContainer\" data-end=\"1070\" data-start=\"465\"\u003eThe 10-1832 is used with Fike clean agent suppression systems, including SHP Pro®, Cheetah® Xi, and Cheetah® Xi 50 releasing panels. It stores the electrical energy required to actuate the gas cartridge actuator (GCA) while continuously supervising the releasing circuit for open and ground faults. The module supports both Class A and Class B wiring configurations and is mounted in a standard 4-inch square electrical junction box adjacent to the suppression container. Parallel wiring through the ARM III ensures that a fault in one actuator does not disable the entire releasing system.\u003c\/p\u003e\n\u003cp data-end=\"1106\" data-start=\"1091\"\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-end=\"2309\" data-start=\"1108\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"2068\" data-start=\"1260\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1873\" data-start=\"1167\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1931\" data-start=\"1190\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1773\" data-start=\"1117\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1818\" data-start=\"1097\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1747\" data-start=\"1099\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1752\" data-start=\"1103\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1756\" data-start=\"1087\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1195\" data-end=\"1821\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1129\" data-end=\"1770\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1183\" data-end=\"1910\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1121\" data-end=\"1802\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1797\" data-start=\"1102\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"2192\" data-start=\"1321\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"2020\" data-start=\"1268\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1873\" data-start=\"1155\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1876\" data-start=\"1175\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1759\" data-start=\"1100\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1830\" data-start=\"1129\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"2068\" data-start=\"1308\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1945\" data-start=\"1174\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"2043\" data-start=\"1239\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1810\" data-start=\"1119\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"2023\" data-start=\"1329\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"2116\" data-start=\"1363\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1977\" data-start=\"1296\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"2036\" data-start=\"1360\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"2101\" data-start=\"1179\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"2123\" data-start=\"1129\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1957\" data-start=\"1112\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1003\" data-end=\"1658\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1007\" data-end=\"1642\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1193\" data-end=\"1892\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1135\" data-end=\"1884\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1144\" data-end=\"1936\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1053\" data-end=\"1804\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1243\" data-end=\"2040\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1183\" data-end=\"1894\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1602\" data-start=\"852\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1632\" data-start=\"918\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1928\" data-start=\"1139\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"974\" data-end=\"1693\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1077\" data-end=\"1800\"\u003e\n\u003cli data-section-id=\"1ejr581\" data-start=\"1077\" data-end=\"1173\"\u003eParallel Actuator Wiring: Allows multiple gas cartridge actuators to be connected in parallel.\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1661ck2\" data-start=\"1174\" data-end=\"1257\"\u003eSupervised Release Circuit: Monitors wiring for open and ground fault conditions.\u003c\/li\u003e\n\u003cli data-section-id=\"1yfjyra\" data-start=\"1258\" data-end=\"1350\"\u003eEnergy Storage Circuit: Stores the energy required to activate the gas cartridge actuator.\u003c\/li\u003e\n\u003cli data-section-id=\"1nifhqp\" data-start=\"1351\" data-end=\"1430\"\u003eClass A \u0026amp; Class B Compatible: Supports both supervised wiring configurations.\u003c\/li\u003e\n\u003cli data-section-id=\"4n3dz\" data-start=\"1431\" data-end=\"1509\"\u003ePolarity Indicator: Integrated LED indicates reversed field wiring polarity.\u003c\/li\u003e\n\u003cli data-section-id=\"12sxom5\" data-start=\"1510\" data-end=\"1597\"\u003eSolid-State Design: Provides dependable long-term operation with minimal maintenance.\u003c\/li\u003e\n\u003cli data-section-id=\"gdgafc\" data-start=\"1598\" data-end=\"1702\"\u003eCompatible with Fike Panels: Designed for SHP Pro®, Cheetah® Xi, and Cheetah® Xi 50 releasing systems.\u003c\/li\u003e\n\u003cli data-section-id=\"1pnierh\" data-start=\"1703\" data-end=\"1800\"\u003eCertified Performance: UL Listed and FM Approved for clean agent fire suppression applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1802\" data-end=\"1981\"\u003eThe 10-1832 delivers the reliability and precision required for supervised clean agent release circuits in critical fire suppression systems.\u003c\/p\u003e","brand":"Fike","offers":[{"title":"Default Title","offer_id":52140972998954,"sku":"10-1832","price":345.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/10-1832-1.jpg?v=1785256920","url":"https:\/\/iqelectro.com\/products\/fike-10-1832-arm-iii-agent-release-module-for-clean-agent-systems","provider":"IQElectro","version":"1.0","type":"link"}