{"product_id":"fike-10-2321-remote-display-unit-old-version-rdu","title":"Fike 10-2321 Remote Display Unit Old Version RDU","description":"\u003ch4 class=\"PDq2pG_selectionAnchorContainer\" data-end=\"14\" data-start=\"0\"\u003eDescription\u003cspan class=\"PDq2pG_selectionAnchor\" aria-hidden=\"true\"\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp data-end=\"389\" data-start=\"16\"\u003eThe Fike 10-2321 is an older-version Remote Display Unit (RDU) designed to provide remote annunciation and system status indication for compatible Fike intelligent fire alarm control panels. It duplicates key panel information on a backlit LCD display, allowing operators to monitor system conditions from a convenient remote location. The backbox is not included.\u003c\/p\u003e\n\u003cp data-end=\"389\" data-start=\"16\"\u003e \u003c\/p\u003e\n\u003cp data-end=\"389\" data-start=\"16\"\u003e \u003c\/p\u003e\n\u003ch4 data-end=\"389\" data-start=\"16\"\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable style=\"width: 90.2174%; height: 303.907px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.2384%;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.5183%;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 10px;\"\u003e\n\u003ctd style=\"width: 32.2384%;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.5183%;\"\u003eFike\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.2384%;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.5183%;\"\u003eFire Alarm Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.2384%;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.5183%;\"\u003e10-2321\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.2384%;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.5183%;\"\u003eRemote Annunciators\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.2384%;\"\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.5183%;\"\u003eRemote Display Unit (Old Version RDU)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.2384%;\"\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.5183%;\"\u003eBacklit LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.2384%;\"\u003e\u003cstrong\u003eCommunication Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.5183%;\"\u003eRS-485 serial bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.2384%;\"\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.5183%;\"\u003e24 VDC regulated (15–30 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.2384%;\"\u003e\u003cstrong\u003eStandby Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.5183%;\"\u003e36 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 32.2384%;\"\u003e\u003cstrong\u003eMaximum Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.5183%;\"\u003e139 mA (backlight, LEDs, and piezo active)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 32.2384%;\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.5183%;\"\u003e32 to 120°F (0 to 49°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 32.2384%;\"\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.5183%;\"\u003eUp to 93% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 32.2384%;\"\u003e\u003cstrong\u003eCompatible Systems\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.5183%;\"\u003eFike CyberCat and Cheetah intelligent fire alarm control panels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 32.2384%;\"\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.5183%;\"\u003eSurface or flush mount (backbox not included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 32.2384%;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.5183%;\"\u003e0.01 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4 data-end=\"411\" data-start=\"391\"\u003eInformation About \u003cspan data-sheets-root=\"1\"\u003e10-2321\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp class=\"PDq2pG_selectionAnchorContainer\" data-end=\"1070\" data-start=\"465\"\u003eThe 10-2321 is a remote display module developed for legacy Fike intelligent fire alarm systems, including compatible CyberCat and Cheetah control panels. It communicates with the host panel through a supervised RS-485 serial communication bus, providing real-time display of alarm, supervisory, and trouble events. The remote display features an illuminated LCD, integrated status LEDs, and operator navigation controls for reviewing active system events. Designed for indoor commercial installations, the unit offers reliable remote monitoring without requiring installation at the main fire alarm control panel.\u003c\/p\u003e\n\u003cp data-end=\"1106\" data-start=\"1091\"\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-end=\"2309\" data-start=\"1108\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"2068\" data-start=\"1260\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1873\" data-start=\"1167\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1931\" data-start=\"1190\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1773\" data-start=\"1117\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1818\" data-start=\"1097\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1747\" data-start=\"1099\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1752\" data-start=\"1103\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1756\" data-start=\"1087\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1195\" data-end=\"1821\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1129\" data-end=\"1770\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1183\" data-end=\"1910\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1121\" data-end=\"1802\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1797\" data-start=\"1102\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"2192\" data-start=\"1321\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"2020\" data-start=\"1268\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1873\" data-start=\"1155\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1876\" data-start=\"1175\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1759\" data-start=\"1100\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1830\" data-start=\"1129\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"2068\" data-start=\"1308\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1945\" data-start=\"1174\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"2043\" data-start=\"1239\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1810\" data-start=\"1119\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"2023\" data-start=\"1329\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"2116\" data-start=\"1363\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1977\" data-start=\"1296\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"2036\" data-start=\"1360\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"2101\" data-start=\"1179\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"2123\" data-start=\"1129\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1957\" data-start=\"1112\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1003\" data-end=\"1658\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1007\" data-end=\"1642\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1193\" data-end=\"1892\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1135\" data-end=\"1884\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1144\" data-end=\"1936\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1053\" data-end=\"1804\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1243\" data-end=\"2040\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1183\" data-end=\"1894\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1602\" data-start=\"852\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1632\" data-start=\"918\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1928\" data-start=\"1139\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"974\" data-end=\"1693\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1077\" data-end=\"1800\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1054\" data-end=\"1790\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1208\" data-end=\"2062\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"922\" data-end=\"1595\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"934\" data-end=\"1622\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1103\" data-end=\"1879\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1084\" data-end=\"1814\"\u003e\n\u003cli data-section-id=\"1szowq4\" data-start=\"1084\" data-end=\"1179\"\u003eRemote System Annunciation: Displays real-time fire alarm system status at a remote location.\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"y9it65\" data-start=\"1180\" data-end=\"1263\"\u003eLegacy RDU Design: Older-version Remote Display Unit for compatible Fike systems.\u003c\/li\u003e\n\u003cli data-section-id=\"1arxeao\" data-start=\"1264\" data-end=\"1353\"\u003eBacklit LCD Display: Provides clear viewing of alarms, supervisory, and trouble events.\u003c\/li\u003e\n\u003cli data-section-id=\"136ew3c\" data-start=\"1354\" data-end=\"1454\"\u003eRS-485 Communication: Connects to the host control panel through a supervised two-wire RS-485 bus.\u003c\/li\u003e\n\u003cli data-section-id=\"f6wccb\" data-start=\"1455\" data-end=\"1558\"\u003eStatus LED Indicators: Includes LEDs for Power, Alarm, Trouble, Supervisory, and Silenced conditions.\u003c\/li\u003e\n\u003cli data-section-id=\"14q9pi0\" data-start=\"1559\" data-end=\"1651\"\u003eEvent Navigation: Allows operators to review current system events using onboard controls.\u003c\/li\u003e\n\u003cli data-section-id=\"1kd37qe\" data-start=\"1652\" data-end=\"1753\"\u003eCompatible Fire Panels: Designed for selected Fike CyberCat and Cheetah intelligent control panels.\u003c\/li\u003e\n\u003cli data-section-id=\"3zxrdf\" data-start=\"1754\" data-end=\"1814\"\u003eBackbox Not Included: Supplied without a mounting backbox.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1816\" data-end=\"1953\"\u003eThe 10-2321 delivers the reliability and precision required for remote monitoring and annunciation in compatible Fike fire alarm systems.\u003c\/p\u003e","brand":"Fike","offers":[{"title":"Default Title","offer_id":52141095747882,"sku":"10-2321","price":992.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/s-l1600_babc6c5f-5fe1-41f6-b04a-2a17afab1048.webp?v=1785261325","url":"https:\/\/iqelectro.com\/products\/fike-10-2321-remote-display-unit-old-version-rdu","provider":"IQElectro","version":"1.0","type":"link"}