{"product_id":"fike-10-2627-rev-c-ethernet-communication-module-without-enclosure","title":"Fike 10-2627 Rev C Ethernet Communication Module Without Enclosure","description":"\u003ch4 class=\"PDq2pG_selectionAnchorContainer\" data-end=\"14\" data-start=\"0\"\u003eDescription\u003cspan class=\"PDq2pG_selectionAnchor\" aria-hidden=\"true\"\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp data-end=\"389\" data-start=\"16\"\u003eThe Fike 10-2627 is an Ethernet communication module designed to provide network connectivity for compatible Fike fire alarm control panels without requiring a dedicated enclosure. The module enables secure Ethernet communication between fire alarm systems, allowing remote event transmission, system monitoring, and network integration for proprietary supervising station applications.\u003c\/p\u003e\n\u003cp data-end=\"389\" data-start=\"16\"\u003e \u003c\/p\u003e\n\u003cp data-end=\"389\" data-start=\"16\"\u003e \u003c\/p\u003e\n\u003ch4 data-end=\"389\" data-start=\"16\"\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable style=\"width: 90.2174%; height: 245.126px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.8743%;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.8824%;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.8743%;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.8824%;\"\u003eFike\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.8743%;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.8824%;\"\u003eFire Alarm Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 10px;\"\u003e\n\u003ctd style=\"width: 34.8743%;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.8824%;\"\u003e10-2627\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.8743%;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.8824%;\"\u003eEthernet Communication Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.8743%;\"\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.8824%;\"\u003eEthernet communication module (without enclosure)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.8743%;\"\u003e\u003cstrong\u003eRevision\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.8824%;\"\u003eRev C signaling board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.8743%;\"\u003e\u003cstrong\u003ePower Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.8824%;\"\u003e15–30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.8743%;\"\u003e\u003cstrong\u003eCurrent Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.8824%;\"\u003e97 mA standby, 134 mA alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 34.8743%;\"\u003e\u003cstrong\u003eEthernet Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.8824%;\"\u003eRJ45, 10Base-T LAN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.8743%;\"\u003e\u003cstrong\u003ePanel Communication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.8824%;\"\u003eRS485 peripheral bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.8743%;\"\u003e\u003cstrong\u003eMaximum RS485 Distance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.8824%;\"\u003e4,000 ft (1,219 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.8743%;\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.8824%;\"\u003e32°F to 120°F (0°C to 49°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.8743%;\"\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.8824%;\"\u003eInside compatible FACU or optional remote enclosure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.8743%;\"\u003e\u003cstrong\u003eCompatible Panels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.8824%;\"\u003eFike Cheetah Xi, CyberCat 254, CyberCat 1016\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.8743%;\"\u003e\u003cstrong\u003eStatus Indicator\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.8824%;\"\u003ePanel communication LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.8743%;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.8824%;\"\u003e0.8 lb (0.36 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4 data-end=\"411\" data-start=\"391\"\u003eInformation About \u003cspan data-sheets-root=\"1\"\u003e10-2627\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp class=\"PDq2pG_selectionAnchorContainer\" data-end=\"1070\" data-start=\"465\"\u003eThe 10-2627 is a Rev C signaling board that interfaces compatible Fike CyberCat and Cheetah Xi fire alarm control panels with a standard Ethernet LAN or WAN network. It communicates with the host panel through an RS485 peripheral bus while providing a 10Base-T Ethernet connection via an RJ45 port. The module supports remote monitoring by transmitting system history and event information between geographically separated fire alarm control panels. Designed as the circuit board version of the Ethernet assembly, it is supplied without an enclosure for installation inside a compatible panel or mounting assembly.\u003c\/p\u003e\n\u003cp data-end=\"1106\" data-start=\"1091\"\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-end=\"2309\" data-start=\"1108\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"2068\" data-start=\"1260\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1873\" data-start=\"1167\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1931\" data-start=\"1190\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1773\" data-start=\"1117\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1818\" data-start=\"1097\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1747\" data-start=\"1099\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1752\" data-start=\"1103\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1756\" data-start=\"1087\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1195\" data-end=\"1821\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1129\" data-end=\"1770\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1183\" data-end=\"1910\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1121\" data-end=\"1802\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1797\" data-start=\"1102\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"2192\" data-start=\"1321\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"2020\" data-start=\"1268\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1873\" data-start=\"1155\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1876\" data-start=\"1175\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1759\" data-start=\"1100\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1830\" data-start=\"1129\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"2068\" data-start=\"1308\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1945\" data-start=\"1174\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"2043\" data-start=\"1239\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1810\" data-start=\"1119\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"2023\" data-start=\"1329\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"2116\" data-start=\"1363\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1977\" data-start=\"1296\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"2036\" data-start=\"1360\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"2101\" data-start=\"1179\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"2123\" data-start=\"1129\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1957\" data-start=\"1112\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1003\" data-end=\"1658\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1007\" data-end=\"1642\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1193\" data-end=\"1892\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1135\" data-end=\"1884\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1144\" data-end=\"1936\"\u003e\n\u003cli data-section-id=\"sh7px7\" data-start=\"1144\" data-end=\"1235\"\u003eEthernet Network Interface: Provides 10Base-T Ethernet connectivity through an RJ45 port.\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1mamv9w\" data-start=\"1236\" data-end=\"1342\"\u003eRemote Panel Communication: Supports transmission of fire alarm events between remote compatible panels.\u003c\/li\u003e\n\u003cli data-section-id=\"76cmiu\" data-start=\"1343\" data-end=\"1441\"\u003eRS485 Host Interface: Connects to the fire alarm control panel through the RS485 peripheral bus.\u003c\/li\u003e\n\u003cli data-section-id=\"1j2k3yw\" data-start=\"1442\" data-end=\"1541\"\u003eEnclosure-Free Design: Supplied as a standalone circuit board for compatible mounting assemblies.\u003c\/li\u003e\n\u003cli data-section-id=\"1b2idcy\" data-start=\"1542\" data-end=\"1645\"\u003eLong Communication Distance: Supports RS485 connections up to 4,000 ft (1,219 m) from the host panel.\u003c\/li\u003e\n\u003cli data-section-id=\"1l8t39y\" data-start=\"1646\" data-end=\"1740\"\u003eLED Status Indicator: Displays module communication status with the connected control panel.\u003c\/li\u003e\n\u003cli data-section-id=\"1l5t5g1\" data-start=\"1741\" data-end=\"1843\"\u003eFlexible Power Input: Operates from the host panel or a regulated 15–30 VDC fire alarm power supply.\u003c\/li\u003e\n\u003cli data-section-id=\"1rtqog3\" data-start=\"1844\" data-end=\"1936\"\u003eCompatible Fire Panels: Designed for Fike CyberCat 254\/1016 and Cheetah Xi control panels.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1938\" data-end=\"2122\"\u003eThe 10-2627 delivers the reliability and precision required for Ethernet communication and remote event reporting in networked fire alarm systems.\u003c\/p\u003e","brand":"Fike","offers":[{"title":"Default Title","offer_id":52140754043178,"sku":"10-2627","price":767.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/10-2627.jpg?v=1785251141","url":"https:\/\/iqelectro.com\/products\/fike-10-2627-rev-c-ethernet-communication-module-without-enclosure","provider":"IQElectro","version":"1.0","type":"link"}