{"product_id":"fire-lite-ann-rly-ann-bus-10-programmable-form-c-relay-module-for-fire-alarm-panels","title":"Fire-Lite ANN-RLY ANN-Bus 10 Programmable Form C Relay Module for Fire Alarm Panels","description":"\u003ch4 class=\"PDq2pG_selectionAnchorContainer\"\u003eDescription\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp dir=\"auto\" data-start=\"16\" data-end=\"396\"\u003e\u003cmeta charset=\"UTF-8\"\u003eThe Fire-Lite ANN-RLY is an ANN-Bus relay module designed to add programmable dry-contact outputs to compatible Fire-Lite fire alarm control panels. Fire-Lite part number ANN-RLY provides 10 individually programmable Form C relays for controlling or signaling alarm, trouble, supervisory, AC-loss, waterflow, zone, and other system conditions.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable style=\"width: 100%; height: 529.032px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 30.5184%; height: 19.5938px;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.806%; height: 19.5938px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 30.5184%; height: 19.5938px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.806%; height: 19.5938px;\"\u003eFire-Lite\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 30.5184%; height: 19.5938px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.806%; height: 19.5938px;\"\u003eFire Alarm \u0026amp; Life Safety\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 30.5184%; height: 19.5938px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.806%; height: 19.5938px;\"\u003eANN-RLY\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 30.5184%; height: 19.5938px;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.806%; height: 19.5938px;\"\u003eRelay Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 30.5184%; height: 19.5938px;\"\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.806%; height: 19.5938px;\"\u003eProgrammable ANN-Bus Relay Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 30.5184%; height: 19.5938px;\"\u003e\u003cstrong\u003eNumber of Relays\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.806%; height: 19.5938px;\"\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 30.5184%; height: 19.5938px;\"\u003e\u003cstrong\u003eRelay Contact Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.806%; height: 19.5938px;\"\u003eForm C (SPDT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 30.5184%; height: 19.5938px;\"\u003e\u003cstrong\u003eRelay Programming\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.806%; height: 19.5938px;\"\u003eIndividually Programmable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 30.5184%; height: 19.5938px;\"\u003e\u003cstrong\u003eCommunication Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.806%; height: 19.5938px;\"\u003eANN-Bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 30.5184%; height: 19.5938px;\"\u003e\u003cstrong\u003eData Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.806%; height: 19.5938px;\"\u003e2-Wire Serial Interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 30.5184%; height: 19.5938px;\"\u003e\u003cstrong\u003eOperating Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.806%; height: 19.5938px;\"\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 30.5184%; height: 19.5938px;\"\u003e\u003cstrong\u003ePower Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.806%; height: 19.5938px;\"\u003e2 Wires; Host FACP or Remote Power Supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 30.5184%; height: 19.5938px;\"\u003e\u003cstrong\u003eCombined Wiring\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.806%; height: 19.5938px;\"\u003eSingle 4-Conductor Unshielded Cable for Power and Data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 30.5184%; height: 39.1875px;\"\u003e\u003cstrong\u003eMaximum ANN-Bus Devices\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.806%; height: 39.1875px;\"\u003eUp to 8 Devices per Compatible FACP ANN-Bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 30.5184%; height: 39.1875px;\"\u003e\u003cstrong\u003eTypical Programmable Functions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.806%; height: 39.1875px;\"\u003eAlarm, Trouble, Supervisory, AC Loss, Waterflow Delay, Input Zones, Silenceable Alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 30.5184%; height: 19.5938px;\"\u003e\u003cstrong\u003eRelay Contact Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.806%; height: 19.5938px;\"\u003e2.0 A @ 30 VDC Resistive; 0.5 A @ 30 VAC Resistive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 30.5184%; height: 19.5938px;\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.806%; height: 19.5938px;\"\u003e32°F to 120°F (0°C to 49°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 30.5184%; height: 19.5938px;\"\u003e\u003cstrong\u003eOperating Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.806%; height: 19.5938px;\"\u003eUp to 93% RH, Non-Condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 30.5184%; height: 39.1875px;\"\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.806%; height: 39.1875px;\"\u003eInside Compatible FACP Enclosure or Battery Area with Appropriate Mounting Bracket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 30.5184%; height: 19.5938px;\"\u003e\u003cstrong\u003eListings \/ Approvals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.806%; height: 19.5938px;\"\u003eUL 864, ULC Listed, FM Approved\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 30.5184%; height: 19.5938px;\"\u003e\u003cstrong\u003eUL File \/ Listing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.806%; height: 19.5938px;\"\u003eS2424\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 30.5184%; height: 19.5938px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.806%; height: 19.5938px;\"\u003eApprox. 5.6 oz (159 g)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About \u003cspan data-sheets-root=\"1\"\u003eANN-RLY\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eThe ANN-RLY is an ANN-Bus accessory module that expands the output capabilities of compatible Fire-Lite fire alarm control systems without requiring conventional relay wiring back to individual panel outputs. It communicates with the host FACP through a two-wire ANN-Bus serial data connection and uses an additional two conductors for 24 VDC power, allowing power and communications to share a single four-conductor unshielded cable. The module can receive operating power directly from a compatible FACP or an approved remote power supply and can be installed within supported panel enclosures using the appropriate mounting location or optional bracket. Up to eight compatible ANN-Bus devices can share an FACP ANN-Bus, allowing the relay module to operate alongside annunciators and other supported ANN-Bus accessories.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eTen Programmable Relays: Provides 10 individually programmable Form C relay outputs for fire alarm system control and signaling.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eForm C Contacts: Each relay provides normally open, normally closed, and common connections for flexible external circuit interfacing.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMultiple Relay Functions: Outputs can be assigned to alarm, trouble, supervisory, AC loss, waterflow delay, input zones, silenceable alarm, and other supported panel events.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eANN-Bus Communication: Uses the Fire-Lite ANN-Bus serial communication format for integration with compatible fire alarm control panels.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFour-Wire Installation: Requires two conductors for serial data and two conductors for 24 VDC operating power.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eUnshielded Cable Support: Power and communications can be carried over a single four-conductor unshielded cable within installation requirements.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFlexible Power Source: Can receive 24 VDC from the host fire alarm panel or a compatible remote power supply.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMultiple Device Support: Up to eight ANN-Bus devices can be connected to each supported FACP ANN-Bus.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFlexible Installation: Can be mounted within compatible FACP enclosures, including supported chassis or battery-area mounting arrangements.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSimple Programming: Relay functions are assigned through the compatible host control panel with minimal module-specific configuration.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSupervised Communication: ANN-Bus integration enables the host system to monitor communications with connected compatible devices.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLife-Safety Approvals: Designed for listed fire alarm installations with UL, ULC, and FM approvals applicable to supported configurations.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eThe ANN-RLY delivers the reliability and precision required for programmable relay control, equipment interfacing, and auxiliary signaling in addressable fire alarm systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp id=\"p-rc_c7b8f4fae39e183e-25\"\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Edwards","offers":[{"title":"Default Title","offer_id":52810932617514,"sku":"ANN-RLY","price":315.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/s-l1600_ab46bd2a-ccde-49f9-8034-2fcd92afa673.png?v=1790884418","url":"https:\/\/iqelectro.com\/products\/fire-lite-ann-rly-ann-bus-10-programmable-form-c-relay-module-for-fire-alarm-panels","provider":"IQElectro","version":"1.0","type":"link"}