{"product_id":"fire-lite-ecc-ce4-audio-zone-expander-module-quick-delivery","title":"ECC-CE4 | Fire-Lite Distributed Audio Zone Expander, 4 Supervised Circuits","description":"\u003ch4\u003e\u003cstrong\u003eDescription \u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe Fire-Lite ECC-CE4 is a distributed audio zone expander module designed to add four additional supervised audio circuits to the ECC-50DA(E) or ECC-125DA(E) amplifiers. This compact and modular device enhances system flexibility and ensures reliable expansion of Fire-Lite emergency communication and voice evacuation systems.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eTechnical Specifications \u003c\/strong\u003e\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFire-Lite Alarms by Honeywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFire Safety\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eECC-CE4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAudio Circuit Expander\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Location\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInside ECC-50DA(E) or ECC-125DA(E) cabinet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupported Circuits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFour audio circuits, Style Y (Class B) or Style Z (Class A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50W of 25V audio power, expandable to 100W RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOptional Transformer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e70.7 VRMS conversion transformer available\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConfiguration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWeb-based programming via ECC-50\/100(E)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtocol Support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem Sensor®, Wheelock®, Gentex® synchronization\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eListings \u0026amp; Approvals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL 2572, UL 864\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduction Status\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eActive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnit of Measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEach (EA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003cspan style=\"font-size: 0.875rem;\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eInformation About ECC-CE4\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe ECC-CE4 is a circuit expander module built for integration within the Fire-Lite ECC-50\/100(E) Emergency Command Center and its distributed amplifiers. It mounts directly inside the ECC-50DA(E) or ECC-125DA(E) cabinet, providing up to four Style Z (Class A) or Style Y (Class B) speaker circuits. With removable terminal blocks for simplified servicing and UL 2572\/UL 864 compliance, the ECC-CE4 ensures seamless and code-compliant system expansion. Its design supports synchronization protocols for System Sensor, Wheelock, and Gentex notification appliances.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAdditional Circuits: Expands ECC-50DA(E) and ECC-125DA(E) units with four supervised audio circuits.\u003c\/li\u003e\n\u003cli\u003eFlexible Wiring: Supports Style Z (Class A) or Style Y (Class B) speaker circuits.\u003c\/li\u003e\n\u003cli\u003eEasy Installation: Mounts inside the amplifier cabinet for space efficiency.\u003c\/li\u003e\n\u003cli\u003eService-Friendly: Removable terminal blocks simplify servicing and replacement.\u003c\/li\u003e\n\u003cli\u003eProtocol Compatibility: Works with System Sensor, Wheelock, and Gentex sync protocols.\u003c\/li\u003e\n\u003cli\u003eHigh Power Capability: Supports up to 50W of 25V audio power, expandable to 100W RMS.\u003c\/li\u003e\n\u003cli\u003eOptional Transformer: 70.7 VRMS conversion transformer available for the primary amplifier.\u003c\/li\u003e\n\u003cli\u003eCode-Compliant: UL 2572 and UL 864 listed for mass notification and emergency voice evacuation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe ECC-CE4 delivers the reliability and scalability required for expanding Fire-Lite emergency voice systems.\u003c\/p\u003e","brand":"Fire-Lite","offers":[{"title":"Default Title","offer_id":50644505788714,"sku":"ECC-CE4","price":497.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/1024747694_1.jpg?v=1759242094","url":"https:\/\/iqelectro.com\/products\/fire-lite-ecc-ce4-audio-zone-expander-module-quick-delivery","provider":"IQElectro","version":"1.0","type":"link"}