{"product_id":"fire-lite-ecc-ce6-speaker-circuit-expander-ships-overnight","title":"ECC-CE6 | Fire-Lite Speaker Circuit Expander Module, 6 Supervised Audio Circuits","description":"\u003ch4\u003e\u003cstrong\u003eDescription \u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe Fire-Lite ECC-CE6 is a speaker circuit and zone expander module that adds six additional audio circuits to the ECC-50\/100 Emergency Command Center. With support for both Class A (Style Z) and Class B (Style Y) wiring, it enhances flexibility in emergency voice and evacuation systems. This module is designed for easy installation directly onto the ECC-50\/100 main control board.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eTechnical Specifications \u003c\/strong\u003e\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFire-Lite Alarms by Honeywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFire Safety\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eECC-CE6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eControl Panel Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDirectly onto ECC-50\/100 main board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAudio Circuits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSix total: 3 primary and 3 secondary\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWiring Styles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClass A (Style Z) or Class B (Style Y)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConfiguration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWeb-based programming via ECC-50\/100 utility\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eECC-50\/100(E), ECC-50W-25\/70V, ECC-XRM-70V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupervision\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAll circuits supervised and power-limited\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransformer Requirement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eECC-XRM-70V required for 70V systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSecondary Circuits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRequire ECC-50W-25\/70V amplifier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eListings \u0026amp; Approvals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL 2572, UL 864\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHoneywell International\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnit of Measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEach (EA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduction Status\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eActive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003cspan style=\"font-size: 0.875rem;\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eInformation About ECC-CE6\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe ECC-CE6 is an expansion module that integrates with the Fire-Lite ECC-50\/100(E) series, providing three primary and three secondary supervised speaker circuits. It mounts directly onto the ECC-50\/100 control board and is configured through a web-based programming utility for simplified setup. For 70V systems, it must be installed with the ECC-XRM-70V transformer to maintain compatibility. Its modular design allows system designers to scale voice evacuation and mass notification solutions efficiently, while removable terminal blocks make servicing and replacement straightforward.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eExpanded Capacity: Adds six supervised speaker circuits (three primary and three secondary) to the ECC-50\/100.\u003c\/li\u003e\n\u003cli\u003eFlexible Wiring: Supports Class A (Style Z) and Class B (Style Y) speaker configurations.\u003c\/li\u003e\n\u003cli\u003eWeb-Based Configuration: Circuits are programmed through the ECC-50\/100 online utility for simple setup.\u003c\/li\u003e\n\u003cli\u003eIntegrated Mounting: Attaches directly to the ECC-50\/100 main board with provided standoffs and screws.\u003c\/li\u003e\n\u003cli\u003e70V Compatibility: Works with the ECC-XRM-70V transformer for installations in 70V audio systems.\u003c\/li\u003e\n\u003cli\u003eService-Friendly: Removable terminal blocks simplify wiring, servicing, and replacement.\u003c\/li\u003e\n\u003cli\u003eSupervised Operation: All speaker circuits are supervised and power-limited for code compliance.\u003c\/li\u003e\n\u003cli\u003eSecondary Circuit Use: Optional ECC-50W-25\/70V amplifier required for activating secondary circuits.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe ECC-CE6 delivers the reliability and scalability required for expanding Fire-Lite voice evacuation and emergency communication systems.\u003c\/p\u003e","brand":"Fire-Lite","offers":[{"title":"Default Title","offer_id":50644517847338,"sku":"ECC-CE6","price":654.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/FL-ECCCE6_lg.jpg?v=1759242441","url":"https:\/\/iqelectro.com\/products\/fire-lite-ecc-ce6-speaker-circuit-expander-ships-overnight","provider":"IQElectro","version":"1.0","type":"link"}