{"product_id":"fire-lite-ms-4012-12v-4-zone-conventional-fire-alarm-control-panel","title":"Fire-Lite MS-4012 12V 4-Zone Conventional Fire Alarm Control Panel","description":"\u003ch4 class=\"PDq2pG_selectionAnchorContainer\"\u003eDescription\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp dir=\"auto\" data-start=\"16\" data-end=\"396\"\u003e\u003cmeta charset=\"UTF-8\"\u003eThe Fire-Lite MS-4012 is a conventional four-zone fire alarm control panel designed for 12-volt notification and detection systems in commercial, industrial, and institutional facilities. Fire-Lite part number MS-4012 supervises initiating and notification circuits while providing alarm annunciation, auxiliary relay control, municipal-box signaling, and remote-station connection capabilities.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFire-Lite\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFire Alarm \u0026amp; Life Safety\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMS-4012\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConventional Fire Alarm Control Panels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMS-4000 Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConventional Fire Alarm Control Panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Initiating Zones\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 VDC Nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDetection Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConventional Zoned Detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible Initiating Devices\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTwo-Wire Smoke Detectors and Normally Open Contact Devices\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTypical Initiating Devices\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSmoke Detectors, Heat Detectors, Manual Pull Stations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNotification Devices\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCompatible 12 VDC Bells, Horns, and Other Alarm Appliances\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAlarm Annunciation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIndividual Fire Zone Indication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuxiliary Control\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSupplementary Relay Outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRemote Signaling\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRemote Station \/ Municipal Box Capability\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePrimary Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120 VAC, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSecondary Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRechargeable Standby Batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Supervision\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInitiating Circuits, Notification Circuits, AC Power, and Battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstallation Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWall-Mounted Fire Alarm Control Panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTypical Applications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCommercial, Industrial, and Institutional Buildings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePlate Included\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApprox. 1 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About \u003cspan data-sheets-root=\"1\"\u003eMS-4012\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eThe MS-4012 is a four-zone conventional fire alarm control panel from Fire-Lite's MS-4000 family, with the MS-4012 configured for nominal 12 VDC system devices and the related MS-4024 designed for 24 VDC equipment. It accepts compatible two-wire smoke detectors and normally open initiating devices such as manual pull stations, heat detectors, and other dry-contact alarm devices on its supervised initiating circuits. When an alarm condition is detected, the panel can activate notification appliances, identify the affected zone, operate supplementary relays, and provide outputs for municipal-box or remote-station signaling where configured. The panel is intended for complete supervised fire alarm installations and incorporates primary AC operation, standby battery support, visual system indicators, audible trouble indication, and front-panel controls for system operation and testing.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eFour Detection Zones: Provides four conventional initiating device circuits for independent fire alarm zone monitoring.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e12-Volt System Design: Configured for nominal 12 VDC compatible detection and notification equipment.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eTwo-Wire Detector Support: Accepts compatible conventional two-wire smoke detectors on supervised initiating circuits.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eDry-Contact Compatibility: Supports normally open initiating devices including heat detectors and manual pull stations.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSupervised Alarm Circuits: Monitors initiating and notification wiring for applicable open-circuit and trouble conditions.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eNotification Control: Activates compatible horns, bells, and other notification appliances following an alarm event.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eZone Annunciation: Identifies the initiating fire alarm zone to assist with rapid event location.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAuxiliary Relay Functions: Provides supplementary relay operation for compatible external equipment and control functions.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eRemote Signaling Capability: Supports connection arrangements for remote-station and municipal fire alarm signaling.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eStandby Battery Operation: Uses rechargeable standby batteries to maintain system functionality during loss of primary AC power.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFront-Panel Controls: Provides accessible controls and indicators for alarm, trouble, reset, silence, and system testing functions.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCommercial Fire Protection: Designed for conventional life-safety installations in commercial, industrial, and institutional buildings.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eThe MS-4012 delivers the reliability and precision required for conventional four-zone fire detection, notification control, and supervised life-safety system operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp id=\"p-rc_c7b8f4fae39e183e-25\"\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Fire-Lite","offers":[{"title":"Default Title","offer_id":52811175264554,"sku":"MS-4012","price":2252.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/ms-4012.jpg?v=1790887705","url":"https:\/\/iqelectro.com\/products\/fire-lite-ms-4012-12v-4-zone-conventional-fire-alarm-control-panel","provider":"IQElectro","version":"1.0","type":"link"}