{"product_id":"fire-lite-slc-2ls-addressable-slc-loop-expander-module","title":"Fire-Lite SLC-2LS Addressable SLC Loop Expander Module","description":"\u003ch4 data-start=\"0\" data-end=\"14\" class=\"PDq2pG_selectionAnchorContainer\"\u003eDescription\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp data-start=\"16\" data-end=\"389\"\u003eThe Fire-Lite SLC-2LS is an optional Signaling Line Circuit expander module designed to add a second intelligent addressable loop to compatible MS-9600LS(E) and MS-9600UDLS(E) fire alarm control panels. It expands system capacity from 318 to 636 addressable points while maintaining LiteSpeed communication performance and flexible Class A or Class B wiring configurations. The module is used for larger fire alarm installations requiring additional device capacity without replacing the existing control panel.\u003c\/p\u003e\n\u003cp data-start=\"16\" data-end=\"389\"\u003e \u003c\/p\u003e\n\u003cp data-start=\"16\" data-end=\"389\"\u003e \u003c\/p\u003e\n\u003ch4 data-start=\"16\" data-end=\"389\"\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable style=\"width: 100%; height: 441.063px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 39.5033%; height: 19.5938px;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.1772%; height: 19.5938px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 39.5033%; height: 19.5938px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.1772%; height: 19.5938px;\"\u003eFire-Lite\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 39.5033%; height: 19.5938px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.1772%; height: 19.5938px;\"\u003eFire Alarm Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 39.5033%; height: 19.5938px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.1772%; height: 19.5938px;\"\u003eSLC-2LS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 39.5033%; height: 19.5938px;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.1772%; height: 19.5938px;\"\u003eSLC Loop Expander Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 39.5033%; height: 19.5938px;\"\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.1772%; height: 19.5938px;\"\u003eSignaling Line Circuit Expansion Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 39.5033%; height: 19.5938px;\"\u003e\u003cstrong\u003eCompatible Panels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.1772%; height: 19.5938px;\"\u003eMS-9600LS(E), MS-9600UDLS(E)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 39.5033%; height: 19.5938px;\"\u003e\u003cstrong\u003eAdded Circuits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.1772%; height: 19.5938px;\"\u003e1 additional SLC loop\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 39.5033%; height: 39.1875px;\"\u003e\u003cstrong\u003eTotal Panel Capacity After Expansion\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.1772%; height: 39.1875px;\"\u003eUp to 636 intelligent addressable points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 39.5033%; height: 19.5938px;\"\u003e\u003cstrong\u003eCommunication Protocol\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.1772%; height: 19.5938px;\"\u003eLiteSpeed Protocol\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 39.5033%; height: 19.5938px;\"\u003e\u003cstrong\u003eDetector Capacity per SLC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.1772%; height: 19.5938px;\"\u003eUp to 159 detectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 39.5033%; height: 19.5938px;\"\u003e\u003cstrong\u003eModule Capacity per SLC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.1772%; height: 19.5938px;\"\u003eUp to 159 monitor, control, or relay modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 39.5033%; height: 19.5938px;\"\u003e\u003cstrong\u003eWiring Styles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.1772%; height: 19.5938px;\"\u003eNFPA Style 4, Style 6, Style 7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 39.5033%; height: 19.5938px;\"\u003e\u003cstrong\u003eLoop Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.1772%; height: 19.5938px;\"\u003eIntelligent Addressable SLC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 39.5033%; height: 19.5938px;\"\u003e\u003cstrong\u003eInstallation Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.1772%; height: 19.5938px;\"\u003eInternal control panel expansion module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 39.5033%; height: 19.5938px;\"\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.1772%; height: 19.5938px;\"\u003eAddressable fire alarm system expansion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 39.5033%; height: 39.1875px;\"\u003e\u003cstrong\u003eSupported Devices\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.1772%; height: 39.1875px;\"\u003eFire-Lite intelligent detectors and addressable modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 39.5033%; height: 19.5938px;\"\u003e\u003cstrong\u003eCommunication Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.1772%; height: 19.5938px;\"\u003eDigital polling communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 10px;\"\u003e\n\u003ctd style=\"width: 39.5033%; height: 10px;\"\u003e\u003cstrong\u003eOperating Environment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.1772%; height: 10px;\"\u003eCommercial fire alarm installations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 39.5033%; height: 19.5938px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.1772%; height: 19.5938px;\"\u003eApproximately 0.50 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4 data-start=\"391\" data-end=\"411\"\u003eInformation About \u003cspan data-sheets-root=\"1\"\u003eSLC-2LS\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp data-start=\"559\" data-end=\"1244\" class=\"PDq2pG_selectionAnchorContainer\"\u003eThe SLC-2LS is part of the Fire-Lite addressable system expansion module family, developed to increase the loop capacity of MS-9600LS(E) and MS-9600UDLS(E) fire alarm control panels. The module adds a second Signaling Line Circuit that supports intelligent detectors, monitor modules, control modules, and relay modules using the same LiteSpeed protocol as the primary loop. It allows each SLC to support up to 159 detectors and 159 addressable modules while maintaining compatibility with NFPA Style 4, Style 6, and Style 7 configurations. The SLC-2LS provides a cost-effective expansion solution for commercial fire alarm systems requiring additional coverage and device integration.\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"1246\" data-end=\"1261\"\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1263\" data-end=\"2515\"\u003e\n\u003cli data-start=\"1263\" data-end=\"1379\"\u003eSecond SLC Expansion: Adds an additional Signaling Line Circuit to compatible Fire-Lite fire alarm control panels.\u003c\/li\u003e\n\u003cli data-start=\"1380\" data-end=\"1492\"\u003eMS-9600LS Compatibility: Designed specifically for MS-9600LS(E) and MS-9600UDLS(E) addressable control panels.\u003c\/li\u003e\n\u003cli data-start=\"1493\" data-end=\"1594\"\u003eIncreased System Capacity: Expands panel capability from 318 to 636 intelligent addressable points.\u003c\/li\u003e\n\u003cli data-start=\"1595\" data-end=\"1705\"\u003eLiteSpeed Protocol Support: Uses the same high-speed communication protocol as the panel’s primary SLC loop.\u003c\/li\u003e\n\u003cli data-start=\"1706\" data-end=\"1780\"\u003eDetector Capacity: Supports up to 159 intelligent detectors on each SLC.\u003c\/li\u003e\n\u003cli data-start=\"1781\" data-end=\"1862\"\u003eModule Capacity: Supports up to 159 monitor, control, or relay modules per SLC.\u003c\/li\u003e\n\u003cli data-start=\"1863\" data-end=\"1955\"\u003eFlexible Wiring Configurations: Supports NFPA Style 4, Style 6, and Style 7 SLC operation.\u003c\/li\u003e\n\u003cli data-start=\"1956\" data-end=\"2060\"\u003eHigh-Speed Device Polling: Enables efficient communication by polling multiple devices simultaneously.\u003c\/li\u003e\n\u003cli data-start=\"2061\" data-end=\"2184\"\u003eLarge System Expansion: Allows larger facilities to use one expanded fire alarm control panel instead of multiple panels.\u003c\/li\u003e\n\u003cli data-start=\"2185\" data-end=\"2284\"\u003eAddressable Device Integration: Supports Fire-Lite intelligent detectors and addressable modules.\u003c\/li\u003e\n\u003cli data-start=\"2285\" data-end=\"2394\"\u003ePlug-In Expansion Design: Provides straightforward installation within compatible control panel assemblies.\u003c\/li\u003e\n\u003cli data-start=\"2395\" data-end=\"2515\"\u003eCommercial Fire Protection Support: Designed for schools, offices, healthcare facilities, and industrial applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2517\" data-end=\"2666\"\u003eThe SLC-2LS delivers the reliability and precision required for intelligent fire alarm loop expansion and large-scale addressable system integration.\u003c\/p\u003e","brand":"Fire-Lite","offers":[{"title":"Default Title","offer_id":52130788737322,"sku":"SLC-2LS","price":477.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/SLC-2LS.webp?v=1785096300","url":"https:\/\/iqelectro.com\/products\/fire-lite-slc-2ls-addressable-slc-loop-expander-module","provider":"IQElectro","version":"1.0","type":"link"}