{"product_id":"fireye-60-2207-2-high-discrimination-flame-amplifier-module","title":"Fireye 60-2207-2 High Discrimination Flame Amplifier Module","description":"\u003ch4 class=\"PDq2pG_selectionAnchorContainer\"\u003eDescription\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003eThe Fireye 60-2207-2 is a high-discrimination flame amplifier module designed for burner flame monitoring applications where background radiation may interfere with flame detection. It amplifies the flame detector signal and helps the compatible control distinguish the actual flame signal from radiation produced by adjacent flames or hot refractory.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable height=\"428\" style=\"width: 79.6769%; height: 402.591px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 29.7005px;\"\u003e\n\u003ctd style=\"width: 37.7835%; height: 29.7005px;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.7658%; height: 29.7005px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 25.9245px;\"\u003e\n\u003ctd style=\"width: 37.7835%; height: 25.9245px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.7658%; height: 25.9245px;\"\u003eFireye\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 30.8333px;\"\u003e\n\u003ctd style=\"width: 37.7835%; height: 30.8333px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.7658%; height: 30.8333px;\"\u003eCombustion Controls\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 25.8333px;\"\u003e\n\u003ctd style=\"width: 37.7835%; height: 25.8333px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.7658%; height: 25.8333px;\"\u003e60-2207-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5964px;\"\u003e\n\u003ctd style=\"width: 37.7835%; height: 19.5964px;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.7658%; height: 19.5964px;\"\u003eFlame Amplifiers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5964px;\"\u003e\n\u003ctd style=\"width: 37.7835%; height: 19.5964px;\"\u003e\u003cstrong\u003eAmplifier Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.7658%; height: 19.5964px;\"\u003eHigh Discrimination\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 55.1432px;\"\u003e\n\u003ctd style=\"width: 37.7835%; height: 55.1432px;\"\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.7658%; height: 55.1432px;\"\u003eBurner Flame Monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1927px;\"\u003e\n\u003ctd style=\"width: 37.7835%; height: 39.1927px;\"\u003e\u003cstrong\u003eControl Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.7658%; height: 39.1927px;\"\u003eFireye 25SU5-5011, 25SU5-5012, 25SU3-5168, 25SU3-5166\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5964px;\"\u003e\n\u003ctd style=\"width: 37.7835%; height: 19.5964px;\"\u003e\u003cstrong\u003eBurner Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.7658%; height: 19.5964px;\"\u003eSingle- or Multi-Burner Applications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1927px;\"\u003e\n\u003ctd style=\"width: 37.7835%; height: 39.1927px;\"\u003e\u003cstrong\u003eBackground Radiation Sources\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.7658%; height: 39.1927px;\"\u003eAdjacent Flame Tips, Hot Refractory\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5964px;\"\u003e\n\u003ctd style=\"width: 37.7835%; height: 19.5964px;\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.7658%; height: 19.5964px;\"\u003e-40°F to 160°F (-40°C to 71°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5964px;\"\u003e\n\u003ctd style=\"width: 37.7835%; height: 19.5964px;\"\u003e\u003cstrong\u003eItem Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.7658%; height: 19.5964px;\"\u003e116D55\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5964px;\"\u003e\n\u003ctd style=\"width: 37.7835%; height: 19.5964px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.7658%; height: 19.5964px;\"\u003e0.62 lb \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eInformation About \u003cspan\u003e60-2207-2\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003eThe 60-2207-2 is a flame amplifier intended for use with Fireye 25SU5-5011, 25SU5-5012, 25SU3-5168, and 25SU3-5166 controls. Its high-discrimination design is intended for single- and multi-burner installations where unwanted background radiation can affect flame-signal recognition. The module processes the signal from the flame detector to provide more selective flame discrimination to the connected burner control. It is suitable for industrial combustion and burner-management systems requiring reliable separation of flame signals from background radiation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003eHigh-Discrimination Design: Helps distinguish genuine flame signals from background radiation.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eFlame Amplifier: Amplifies the electrical signal received from the flame detection system.\u003c\/li\u003e\n\u003cli\u003eMulti-Burner Application: Suitable for installations where radiation from adjacent burner flames may be present.\u003c\/li\u003e\n\u003cli\u003eBackground Radiation Rejection: Helps prevent hot refractory and other radiation sources from being interpreted as the monitored flame.\u003c\/li\u003e\n\u003cli\u003eControl Compatibility: Designed for use with Fireye 25SU5-5011, 25SU5-5012, 25SU3-5168, and 25SU3-5166 controls.\u003c\/li\u003e\n\u003cli\u003eBurner Safety Application: Supports flame monitoring within combustion control systems.\u003c\/li\u003e\n\u003cli\u003eIndustrial Construction: Designed for use in demanding burner and combustion-control environments.\u003c\/li\u003e\n\u003cli\u003eOperating Temperature: Listed operating range is -40°F to 160°F (-40°C to 71°C).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe 60-2207-2 delivers the reliability and precision required for burner flame detection and combustion safety applications.\u003c\/p\u003e","brand":"Fireye","offers":[{"title":"Default Title","offer_id":52573173973290,"sku":"60-2207-2","price":4179.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/s-l1600_b87658bd-3bf7-40eb-99cb-431c8cadc352.webp?v=1789142514","url":"https:\/\/iqelectro.com\/products\/fireye-60-2207-2-high-discrimination-flame-amplifier-module","provider":"IQElectro","version":"1.0","type":"link"}