{"product_id":"fireye-bll510-burnerlogix-nema-4-remote-lcd-display-module","title":"Fireye BLL510 BurnerLogix NEMA 4 Remote LCD Display Module","description":"\u003ch4 class=\"PDq2pG_selectionAnchorContainer\"\u003eDescription\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003eThe Fireye BLL510 is a BurnerLogix remote LCD display module designed for monitoring and configuring Fireye burner management control systems. Featuring a 2-line by 16-character LCD screen, NEMA 4 protection, and remote mounting capability with cable connection, it provides clear operating status, diagnostic information, and burner control data.\u003c\/p\u003e\n\u003ch3\u003e\u003cbr\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFireye\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCombustion Controls\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBLL510\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBurner Management Display Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRemote LCD Display Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible System\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFireye BurnerLogix\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLiquid Crystal Display (LCD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay Format\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 Lines x 16 Characters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBurnerLogix Control Connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRemote Panel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNEMA 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20°C to +60°C (-4°F to +140°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFunctions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStatus Display, Diagnostics, Configuration Review, Reset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGas, Oil, and Combination Fuel Burners\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible Controllers\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFireye YB110 \/ YB230 BurnerLogix Chassis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl System Use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBurner Sequencing and Flame Monitoring Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIncluded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApproximately 0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About \u003cspan\u003eBLL510\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003eThe BLL510 is a Fireye BurnerLogix display module designed to work with YB110 and YB230 burner management systems for advanced combustion control monitoring. It provides an alpha-numeric interface that allows operators to view burner status, programmer settings, operating history, and lockout diagnostics through an integrated keypad. The display supports remote installation and communicates with the BurnerLogix control chassis to provide detailed system information in full text format. It is commonly used in commercial and industrial combustion systems including gas, oil, and dual-fuel burners requiring enhanced monitoring and troubleshooting capability.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e2-Line x 16-Character LCD Display: Provides clear alpha-numeric information for burner status and diagnostics.\u003c\/li\u003e\n\u003cli\u003eNEMA 4 Protection: Allows remote mounting in protected outdoor and industrial environments.\u003c\/li\u003e\n\u003cli\u003eBurnerLogix Compatibility: Designed for use with Fireye BurnerLogix burner management control systems.\u003c\/li\u003e\n\u003cli\u003eRemote Display Capability: Enables installation away from the main burner control chassis.\u003c\/li\u003e\n\u003cli\u003eIntegrated Keypad: Allows navigation through menus, settings, and diagnostic information.\u003c\/li\u003e\n\u003cli\u003eOperating Status Monitoring: Displays current burner operating conditions and sequence information.\u003c\/li\u003e\n\u003cli\u003eLockout Diagnostics: Provides detailed fault and shutdown information for troubleshooting.\u003c\/li\u003e\n\u003cli\u003eProgrammer Configuration Access: Allows review of burner control parameters and settings.\u003c\/li\u003e\n\u003cli\u003eCommunication Cable Included: Provides connection between display module and control system.\u003c\/li\u003e\n\u003cli\u003eWide Temperature Range: Operates from -20°C to +60°C (-4°F to +140°F).\u003c\/li\u003e\n\u003cli\u003eIndustrial Combustion Application: Suitable for gas, oil, and combination fuel burner systems.\u003c\/li\u003e\n\u003cli\u003eRemote Reset Function: Allows convenient system reset from the display location.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe BLL510 delivers the reliability and precision required for burner management monitoring, combustion control, and industrial heating system applications.\u003c\/p\u003e","brand":"Fireye","offers":[{"title":"Default Title","offer_id":52579860840746,"sku":"BLL510","price":1099.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/bll510_1.jpg?v=1789161903","url":"https:\/\/iqelectro.com\/products\/fireye-bll510-burnerlogix-nema-4-remote-lcd-display-module","provider":"IQElectro","version":"1.0","type":"link"}