{"product_id":"fireye-ep260-flame-monitor-programmer-module-adjustable-purge-10-15-sec-tfi-recycle","title":"Fireye EP260 Flame-Monitor Programmer Module Adjustable Purge 10\/15-Sec TFI Recycle","description":"\u003ch4 class=\"PDq2pG_selectionAnchorContainer\"\u003eDescription\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003eThe Fireye EP260 is a Flame-Monitor programmer module designed to control burner startup sequencing, purge, ignition trials, running interlocks, and flame-failure response in compatible Fireye combustion safety systems. Fireye part number EP260 provides adjustable purge timing with a 30-second minimum, 10-second PTFI, selectable 10\/15-second MTFI, and recycle operation when the running interlock circuit opens during the firing cycle.\u003c\/p\u003e\n\u003ch3\u003e\u003cbr\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFireye\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCombustion Controls\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEP260\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProgrammer Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFireye EP Series \/ Flame-Monitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFlame Safeguard Programmer Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible System\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFireye Flame-Monitor \/ E110\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible Chassis\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEB700\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFireye ED510\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePurge Timing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSelectable \/ Adjustable, 30 Seconds Minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePilot Trial for Ignition (PTFI)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 Seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMain Trial for Ignition (MTFI)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 or 15 Seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFlame Failure Response Time (FFRT)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 Seconds Maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRunning Interlock Response\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRecycle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLow-Fire Start Check\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFuel Valve End-Switch Check\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePrimary Function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBurner Sequencing and Flame Safeguard Programming\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstallation Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlug-In Programmer Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApprox. 0.5 lb (0.23 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About \u003cspan\u003eEP260\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003eThe EP260 is part of the Fireye EP Series of microprocessor-based programmer modules used with the Flame-Monitor burner management platform. Its plug-in construction is designed for compatible EB700\/E110 Flame-Monitor assemblies and supports the ED510 alphanumeric display for expanded operating status and diagnostic information. The programmer supervises low-fire start position, fuel-valve end-switch conditions, limit switches, combustion-air proving devices, and fuel-pressure switches while controlling the programmed burner sequence. Safe-start checking and continuous running-interlock supervision allow the EP260 to initiate the appropriate recycle or safety-lockout response when monitored conditions occur at an improper point in the operating cycle.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFlame-Monitor Programming: Controls startup, purge, ignition trials, firing operation, and safety response within a compatible Flame-Monitor system.\u003c\/li\u003e\n\u003cli\u003eAdjustable Purge Timing: Provides selectable purge duration with a minimum purge period of 30 seconds.\u003c\/li\u003e\n\u003cli\u003e10-Second PTFI: Provides a 10-second Pilot Trial for Ignition period for establishing and proving the pilot flame.\u003c\/li\u003e\n\u003cli\u003eSelectable MTFI: Supports 10- or 15-second Main Trial for Ignition timing according to system configuration.\u003c\/li\u003e\n\u003cli\u003e4-Second FFRT: Provides a maximum flame-failure response time of approximately four seconds.\u003c\/li\u003e\n\u003cli\u003eRecycle Running Interlocks: Recycles the burner sequence when the running interlock circuit at terminals 3-P opens during the firing period.\u003c\/li\u003e\n\u003cli\u003eSafe-Start Check: Verifies critical burner conditions before permitting the ignition sequence to proceed.\u003c\/li\u003e\n\u003cli\u003eLow-Fire Position Supervision: Requires proof of the proper low-fire starting position before burner startup can continue.\u003c\/li\u003e\n\u003cli\u003eFuel Valve End-Switch Check: Supervises the fuel-valve end-switch circuit as part of the burner safety sequence.\u003c\/li\u003e\n\u003cli\u003eContinuous Interlock Monitoring: Monitors limit switches, airflow switches, fuel-pressure switches, and other connected running interlocks.\u003c\/li\u003e\n\u003cli\u003eED510 Display Support: Compatible with the Fireye ED510 alphanumeric display for operating status, sequence information, and lockout diagnostics.\u003c\/li\u003e\n\u003cli\u003ePlug-In Construction: Modular installation simplifies programmer replacement and maintenance within compatible Flame-Monitor assemblies.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe EP260 delivers the reliability and precision required for burner sequencing, adjustable purge control, ignition timing, interlock supervision, and flame safety management.\u003c\/p\u003e","brand":"Fireye","offers":[{"title":"Default Title","offer_id":52596858978602,"sku":"EP260","price":1199.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/s-l1600_433d1311-4cc1-4566-b52d-ea6860bf87d2.webp?v=1789329521","url":"https:\/\/iqelectro.com\/products\/fireye-ep260-flame-monitor-programmer-module-adjustable-purge-10-15-sec-tfi-recycle","provider":"IQElectro","version":"1.0","type":"link"}