{"product_id":"fireye-epd160-flame-monitor-programmer-module-30-sec-purge-10-15-sec-tfi-non-recycle","title":"Fireye EPD160 Flame-Monitor Programmer Module 30-Sec Purge 10\/15-Sec TFI Non-Recycle","description":"\u003ch4 class=\"PDq2pG_selectionAnchorContainer\"\u003eDescription\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003eThe Fireye EPD160 is a plug-in Flame-Monitor programmer module designed to control burner sequencing, purge timing, ignition trials, and flame-failure response in compatible Fireye E110 systems. Fireye part number EPD160 provides non-recycle operation, modulation control, a 30-second purge sequence, 10-second PTFI, selectable 10\/15-second main trial-for-ignition timing, and a built-in seven-LED diagnostic display.\u003c\/p\u003e\n\u003ch3\u003e\u003cbr\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFireye\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCombustion Controls\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEPD160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProgrammer Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFireye EPD \/ Flame-Monitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFlame Safeguard Programmer Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible System\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFireye E110 Flame-Monitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible Chassis\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEB700\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNon-Recycle \/ Modulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePurge Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 Seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePilot Trial for Ignition (PTFI)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 Seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMain Trial for Ignition (MTFI)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 or 15 Seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFlame Failure Response Time (FFRT)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 Seconds Maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStatus Display\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7 Integral LED Indicators\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFlame Signal Test Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0–10 VDC via Front Test Jacks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOptional Display Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRJ45 for ED510\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTwo RJ Connections for E500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstallation Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlug-In Programmer Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApprox. 0.5 lb (0.23 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About \u003cspan\u003eEPD160\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003eThe EPD160 is part of the Fireye EPD Series of programmer modules developed for the Flame-Monitor burner management platform. Its plug-in electronic construction works with the EB700 chassis used in the E110 Flame-Monitor system and incorporates seven LED indicators that display current operating status and identify the reason for the previous safety lockout. The module provides non-recycle operation with modulation, a 30-second purge sequence, 10-second pilot trial for ignition, selectable main trial timing, and a maximum 4-second flame-failure response time. Communication interfaces include an RJ45 connection for the optional ED510 alphanumeric display and two RJ-style connections for compatible E500 communication equipment, allowing expanded monitoring and diagnostic capability.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFlame-Monitor Programmer: Determines the operating sequence and timing functions of a compatible Fireye E110 burner management system.\u003c\/li\u003e\n\u003cli\u003eNon-Recycle Operation: Configured for non-recycle response during applicable running-interlock or flame-failure conditions.\u003c\/li\u003e\n\u003cli\u003e30-Second Purge: Provides a defined 30-second purge sequence before the ignition portion of the burner cycle.\u003c\/li\u003e\n\u003cli\u003e10-Second PTFI: Provides a 10-second Pilot Trial for Ignition period for establishing and proving pilot flame.\u003c\/li\u003e\n\u003cli\u003eSelectable Main TFI: Provides 10- or 15-second main trial-for-ignition timing according to the configured terminal sequence.\u003c\/li\u003e\n\u003cli\u003e4-Second FFRT: Maximum flame-failure response time is 4 seconds for rapid burner safety response.\u003c\/li\u003e\n\u003cli\u003eModulation Control: Supports modulating burner configurations requiring firing-rate control during normal operation.\u003c\/li\u003e\n\u003cli\u003eSeven-LED Display: Integral LED indicators show current operating status and information related to the last lockout condition.\u003c\/li\u003e\n\u003cli\u003eSafe Start Check: Performs burner safety checks during startup before permitting the programmed ignition sequence to continue.\u003c\/li\u003e\n\u003cli\u003eFlame Signal Test Jacks: Front test points provide a 0–10 VDC output corresponding to flame-signal strength for setup and troubleshooting.\u003c\/li\u003e\n\u003cli\u003eED510 Interface: RJ45 connection supports an optional remote ED510 2-line × 16-character alphanumeric display on compatible engineering revisions.\u003c\/li\u003e\n\u003cli\u003eE500 Communication Support: Dual RJ-style connections allow integration with compatible Fireye E500 communication interfaces.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe EPD160 delivers the reliability and precision required for burner sequencing, ignition timing, flame supervision, and diagnostic control in Fireye Flame-Monitor systems.\u003c\/p\u003e","brand":"Fireye","offers":[{"title":"Default Title","offer_id":52596841185578,"sku":"EPD160","price":2599.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/s-l1600_257ac7e8-5541-4dd9-b7ea-e28f42fb4259.webp?v=1789329154","url":"https:\/\/iqelectro.com\/products\/fireye-epd160-flame-monitor-programmer-module-30-sec-purge-10-15-sec-tfi-non-recycle","provider":"IQElectro","version":"1.0","type":"link"}