{"product_id":"fireye-euv1-ultraviolet-flame-amplifier-module-for-flame-monitor-burner-control-system","title":"Fireye EUV1 Ultraviolet Flame Amplifier Module for Flame-Monitor Burner Control System","description":"\u003ch4 class=\"PDq2pG_selectionAnchorContainer\"\u003eDescription\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003eThe Fireye EUV1 is a standard ultraviolet flame amplifier module designed for the Fireye Flame-Monitor burner management system. Fireye part number EUV1 processes flame signals from compatible non-self-checking UV scanners to provide dependable flame-presence monitoring for gas, oil, and combination-fuel burner applications.\u003c\/p\u003e\n\u003ch3\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFireye\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCombustion Controls\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEUV1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFlame Amplifier Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUltraviolet Flame Amplifier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Family\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFireye Flame-Monitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDetection Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUltraviolet (UV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmplifier Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard \/ Non-Self-Checking\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlug-In Flame Amplifier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible Chassis\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFireye Flame-Monitor Chassis, including EB700 configurations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible Scanners\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUV1A, UV8A, 45UV3, UV90 Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Signal Source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCompatible Fireye UV Flame Scanner\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePrimary Function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUV Flame Signal Amplification and Processing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40°F to 140°F (-40°C to 60°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTypical Applications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBoilers, Burners, Furnaces, Process Combustion Equipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRecommended Burner Duty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIntermittent \/ Normally Cycled Burner Operation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstallation Location\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDedicated Amplifier Module Position in Flame-Monitor Chassis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApprox. 0.4 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About \u003cspan\u003eEUV1\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003eThe EUV1 is a plug-in ultraviolet amplifier from Fireye’s Flame-Monitor family, intended for use with the appropriate UV flame scanner and compatible Flame-Monitor chassis. Its modular construction allows installation in the dedicated amplifier position of the control chassis, where it receives and processes the electrical flame signal generated by the connected scanner. The module supports Fireye UV1A, UV8A, 45UV3, and UV90-series ultraviolet scanners and is intended for non-self-checking UV flame detection applications. It is primarily suited to burners that cycle normally or intermittently; continuous or extended firing applications generally require an appropriate self-checking scanner and amplifier configuration.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUltraviolet Flame Amplification: Processes signals received from compatible Fireye ultraviolet flame scanners.\u003c\/li\u003e\n\u003cli\u003eNon-Self-Checking Design: Intended for standard UV flame detection applications where continuous self-checking is not required.\u003c\/li\u003e\n\u003cli\u003eFlame-Monitor Compatibility: Designed specifically for integration with the Fireye Flame-Monitor burner management system.\u003c\/li\u003e\n\u003cli\u003ePlug-In Module Construction: Installs into the designated amplifier-module guide channels within a compatible Flame-Monitor chassis.\u003c\/li\u003e\n\u003cli\u003eMultiple Scanner Compatibility: Supports UV1A, UV8A, 45UV3, and UV90-series non-self-checking UV scanners.\u003c\/li\u003e\n\u003cli\u003eFlame Signal Processing: Converts the scanner input into a usable flame-presence signal for the burner management control.\u003c\/li\u003e\n\u003cli\u003eBurner Safety Application: Supports flame supervision functions that allow the control system to respond when flame is absent or lost.\u003c\/li\u003e\n\u003cli\u003eBroad Fuel Application: Suitable for compatible gas, oil, and combination-fuel combustion equipment when paired with the correct scanner.\u003c\/li\u003e\n\u003cli\u003eIndustrial Temperature Capability: Designed for operation across a -40°F to 140°F (-40°C to 60°C) ambient temperature range.\u003c\/li\u003e\n\u003cli\u003eModular Service Design: Separate amplifier architecture allows the flame-detection module to be selected according to the scanner technology and application.\u003c\/li\u003e\n\u003cli\u003eBurner System Integration: Suitable for boilers, furnaces, process burners, and other Flame-Monitor-controlled combustion equipment.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe EUV1 delivers the reliability and precision required for ultraviolet flame signal processing and burner flame supervision in Fireye Flame-Monitor combustion control systems.\u003c\/p\u003e","brand":"Fireye","offers":[{"title":"Default Title","offer_id":52596210991402,"sku":"EUV1","price":999.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/s-l1600_ff008984-1ac9-483a-bb78-ec4ae78134d0.webp?v=1789320657","url":"https:\/\/iqelectro.com\/products\/fireye-euv1-ultraviolet-flame-amplifier-module-for-flame-monitor-burner-control-system","provider":"IQElectro","version":"1.0","type":"link"}