{"product_id":"fireye-mauv1-m-series-ii-ultra-violet-amplifier-module-with-2-4-second-ffrt","title":"Fireye MAUV1 M-Series II Ultra-Violet Amplifier Module with 2–4 Second FFRT","description":"\u003ch4 class=\"PDq2pG_selectionAnchorContainer\"\u003eDescription\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003eThe Fireye MAUV1 is an M-Series II ultraviolet amplifier module designed to process flame signals from compatible UV scanners in burner safeguard systems. It provides a 2–4 second Flame Failure Response Time (FFRT), enabling the associated control to respond to loss of detected flame during burner operation.\u003c\/p\u003e\n\u003ch3\u003e\u003cbr\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable style=\"width: 89.9785%; height: 343.095px;\" height=\"610\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 46.5538%; height: 19.5938px;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 53.2044%; height: 19.5938px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 46.5538%; height: 19.5938px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 53.2044%; height: 19.5938px;\"\u003eFireye\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 46.5538%; height: 19.5938px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 53.2044%; height: 19.5938px;\"\u003eBurner Controls\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 46.5538%; height: 19.5938px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 53.2044%; height: 19.5938px;\"\u003eMAUV1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 46.5538%; height: 19.5938px;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 53.2044%; height: 19.5938px;\"\u003eFlame Amplifier Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 46.5538%; height: 19.5938px;\"\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 53.2044%; height: 19.5938px;\"\u003eUltra-Violet Amplifier Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 46.5538%; height: 19.5938px;\"\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 53.2044%; height: 19.5938px;\"\u003eM-Series II\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 46.5538%; height: 19.5938px;\"\u003e\u003cstrong\u003eDetection Technology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 53.2044%; height: 19.5938px;\"\u003eUltraviolet (UV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 46.5538%; height: 19.5938px;\"\u003e\u003cstrong\u003eFlame Failure Response Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 53.2044%; height: 19.5938px;\"\u003e2–4 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 46.5538%; height: 19.5938px;\"\u003e\u003cstrong\u003eControl Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 53.2044%; height: 19.5938px;\"\u003eFireye Modular M-Series II\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 46.5538%; height: 19.5938px;\"\u003e\u003cstrong\u003eCompatible Scanner\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 53.2044%; height: 19.5938px;\"\u003eUV1A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 46.5538%; height: 19.5938px;\"\u003e\u003cstrong\u003eCompatible Scanner\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 53.2044%; height: 19.5938px;\"\u003eUV2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 46.5538%; height: 19.5938px;\"\u003e\u003cstrong\u003eCompatible Scanner\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 53.2044%; height: 19.5938px;\"\u003eUV8A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 10px;\"\u003e\n\u003ctd style=\"width: 46.5538%; height: 10px;\"\u003e\u003cstrong\u003eCompatible Scanner\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 53.2044%; height: 10px;\"\u003e45UV3-1050\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 46.5538%; height: 19.5938px;\"\u003e\u003cstrong\u003eInstallation Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 53.2044%; height: 19.5938px;\"\u003ePlug-In Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 46.5538%; height: 19.5938px;\"\u003e\u003cstrong\u003eDiagnostic Feature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 53.2044%; height: 19.5938px;\"\u003eFlame Signal Test Jacks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 46.5538%; height: 19.5938px;\"\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 53.2044%; height: 19.5938px;\"\u003eBurner Flame Safeguard and Supervision\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 46.5538%; height: 19.5938px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 53.2044%; height: 19.5938px;\"\u003e2 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eInformation About \u003cspan\u003eMAUV1\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003eThe MAUV1 is a plug-in ultraviolet flame amplifier developed for the Fireye Modular M-Series II control platform. It is compatible with Fireye UV1A, UV2, UV8A, and 45UV3-1050 ultraviolet flame scanners and is not intended for self-check scanner applications. The amplifier processes scanner signals while the installed programmer module determines operating characteristics such as purge timing, relight behavior, and burner sequencing. Integrated test jacks allow flame-signal measurement during operation for system setup, diagnostics, and maintenance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003eUV Flame Amplification: Processes ultraviolet flame signals from compatible Fireye scanners.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e2–4 Second FFRT: Provides a Flame Failure Response Time of approximately 2 to 4 seconds.\u003c\/li\u003e\n\u003cli\u003eM-Series II Compatibility: Designed specifically for Fireye Modular M-Series II flame safeguard controls.\u003c\/li\u003e\n\u003cli\u003eMultiple Scanner Support: Compatible with Fireye UV1A, UV2, UV8A, and 45UV3-1050 UV scanners.\u003c\/li\u003e\n\u003cli\u003ePlug-In Construction: Uses a modular plug-in design for integration with the appropriate M-Series II chassis.\u003c\/li\u003e\n\u003cli\u003eFlame Signal Test Jacks: Provides test points for measuring flame signal strength during burner operation.\u003c\/li\u003e\n\u003cli\u003eStandard UV Operation: Intended for standard ultraviolet flame scanners rather than self-check UV scanners.\u003c\/li\u003e\n\u003cli\u003eBurner Safeguard Application: Supports flame-presence supervision in automatically fired burner systems. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe MAUV1 delivers the reliability and precision required for ultraviolet flame detection and burner safeguard control applications.\u003c\/p\u003e","brand":"Fireye","offers":[{"title":"Default Title","offer_id":52575090508074,"sku":"MAUV1","price":435.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/s-l1600_375b30f9-7471-4257-ae7c-c4f5eb62fd81.webp?v=1789146193","url":"https:\/\/iqelectro.com\/products\/fireye-mauv1-m-series-ii-ultra-violet-amplifier-module-with-2-4-second-ffrt","provider":"IQElectro","version":"1.0","type":"link"}