{"product_id":"fireye-mep100-microm-programmer-module-10-second-ptfi-relight-flame-safeguard-control","title":"Fireye MEP100 MicroM Programmer Module 10-Second PTFI Relight Flame Safeguard Control","description":"\u003ch4 class=\"PDq2pG_selectionAnchorContainer\"\u003eDescription\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003eThe Fireye MEP100 is a plug-in programmer module designed for compatible Fireye MicroM flame safeguard controls used on automatically fired burners. Fireye part number MEP100 provides a relight operating sequence with a 10-second Pilot Trial for Ignition (PTFI), coordinating burner startup and automatic ignition retry following specified flame-failure conditions.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cbr\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFireye\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCombustion Controls\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMEP100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProgrammer Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFireye MicroM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFlame Safeguard Programmer Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProgram Function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRelight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePilot Trial for Ignition (PTFI)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 Seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFlame Failure Response\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAutomatic Relight \/ Ignition Retry\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstallation Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlug-In Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible System\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFireye MicroM Modular Flame Safeguard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Supply Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120 VAC or 230 VAC MicroM Configurations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40°F to 140°F (-40°C to 60°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTypical Fuel Applications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGas \/ Oil \/ Combination Gas-Oil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePrimary Function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBurner Sequence and Ignition Timing Control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTypical Equipment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBoilers, Furnaces, Ovens, Process Heaters, Packaged Burners\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApprox. 0.3 lb (0.14 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About \u003cspan\u003eMEP100\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003eThe MEP100 is part of the Fireye MicroM modular flame safeguard system, where the programmer module determines burner operating sequence, ignition timing, and flame-failure response. Its plug-in construction allows it to be installed in a compatible MicroM chassis and used with the appropriate flame detector and amplifier configuration for gas, oil, or combination-fuel burner applications. The MEP100 is specifically configured for relight operation and a 10-second PTFI, allowing the control system to initiate another ignition attempt following a qualifying flame failure rather than immediately requiring manual intervention. MicroM system diagnostics provide operating status and lockout information for commissioning and troubleshooting, while the modular architecture simplifies replacement and configuration of burner safeguard components.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMicroM Programmer Module: Defines the operating sequence and timing functions of a compatible Fireye MicroM flame safeguard system.\u003c\/li\u003e\n\u003cli\u003eRelight Operation: Configured to initiate an automatic ignition retry following specified flame-loss conditions.\u003c\/li\u003e\n\u003cli\u003e10-Second PTFI: Provides a 10-second Pilot Trial for Ignition period for establishing and proving the pilot flame.\u003c\/li\u003e\n\u003cli\u003ePlug-In Construction: Installs directly into the compatible MicroM control chassis for straightforward replacement and servicing.\u003c\/li\u003e\n\u003cli\u003eBurner Sequence Control: Coordinates the required ignition and flame-proving stages within the configured MicroM burner sequence.\u003c\/li\u003e\n\u003cli\u003eFlame Failure Response: Works with the MicroM flame safeguard system to respond to loss of an acceptable flame signal.\u003c\/li\u003e\n\u003cli\u003eDiagnostic Support: Compatible MicroM system interfaces provide operating status and fault or lockout information for troubleshooting.\u003c\/li\u003e\n\u003cli\u003eModular Architecture: Allows the programmer to be combined with appropriate MicroM chassis, flame amplifier, and scanner components.\u003c\/li\u003e\n\u003cli\u003eMultiple Fuel Applications: Suitable for properly configured gas, oil, and combination gas\/oil burner systems.\u003c\/li\u003e\n\u003cli\u003eIndustrial Temperature Capability: Designed for operation from -40°F to 140°F (-40°C to 60°C).\u003c\/li\u003e\n\u003cli\u003e50\/60 Hz System Compatibility: Supports compatible MicroM installations designed for standard 50 Hz or 60 Hz control power.\u003c\/li\u003e\n\u003cli\u003eCombustion Equipment Application: Suitable for compatible boilers, furnaces, ovens, process heaters, and packaged burner systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe MEP100 delivers the reliability and precision required for timed ignition sequencing, relight operation, and flame safeguard management in compatible Fireye MicroM burner systems.\u003c\/p\u003e","brand":"Fireye","offers":[{"title":"Default Title","offer_id":52596830503210,"sku":"MEP100","price":305.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/s-l1600_d140e580-7669-4278-837a-c769de52cf99.webp?v=1789328811","url":"https:\/\/iqelectro.com\/products\/fireye-mep100-microm-programmer-module-10-second-ptfi-relight-flame-safeguard-control","provider":"IQElectro","version":"1.0","type":"link"}