{"product_id":"fireye-mp100-m-series-ii-relight-programmer-module-for-burner-control","title":"Fireye MP100 M-Series II Relight Programmer Module for Burner Control","description":"\u003ch4 class=\"PDq2pG_selectionAnchorContainer\"\u003eDescription\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003eFireye MP100 is a plug-in programmer module for the Fireye Modular M-Series II flame safeguard control system. It provides the operating sequence and ignition control functions for light-oil and gas-fired burners, including a relight function following flame failure.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable style=\"width: 99.941%; height: 333.095px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 26.2661%; height: 19.5938px;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.4379%; height: 19.5938px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 26.2661%; height: 19.5938px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.4379%; height: 19.5938px;\"\u003eFireye\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 26.2661%; height: 19.5938px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.4379%; height: 19.5938px;\"\u003eHVAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 26.2661%; height: 19.5938px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.4379%; height: 19.5938px;\"\u003eMP100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 26.2661%; height: 19.5938px;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.4379%; height: 19.5938px;\"\u003eBurner Control Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 26.2661%; height: 19.5938px;\"\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.4379%; height: 19.5938px;\"\u003eModular M-Series II\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 26.2661%; height: 19.5938px;\"\u003e\u003cstrong\u003ePrimary Function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.4379%; height: 19.5938px;\"\u003eFlame safeguard programmer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 26.2661%; height: 19.5938px;\"\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.4379%; height: 19.5938px;\"\u003eGas and light-oil fired burners\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 26.2661%; height: 19.5938px;\"\u003e\u003cstrong\u003eControl Function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.4379%; height: 19.5938px;\"\u003eRelight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 26.2661%; height: 19.5938px;\"\u003e\u003cstrong\u003eInstallation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.4379%; height: 19.5938px;\"\u003ePlug-in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 26.2661%; height: 19.5938px;\"\u003e\u003cstrong\u003eStatus Indicators\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.4379%; height: 19.5938px;\"\u003eOperating Control, Air Flow, PTFI, Flame On, Alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 26.2661%; height: 19.5938px;\"\u003e\u003cstrong\u003eAmplifier\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.4379%; height: 19.5938px;\"\u003eRequires compatible separately selected amplifier module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 26.2661%; height: 19.5938px;\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.4379%; height: 19.5938px;\"\u003eApproximately 5.75 × 4.0 × 1.75 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 26.2661%; height: 19.5938px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.4379%; height: 19.5938px;\"\u003e 0.4 lb \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4\u003eInformation About \u003cspan\u003eMP100\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003e\u003cmeta charset=\"utf-8\"\u003eThe MP100 is designed as a replacement for Fireye M-Series relight controls and installs directly into compatible M-Series II chassis. Its programmer configuration determines the operating characteristics of the burner control, while the separate amplifier module determines flame scanner compatibility and flame-failure response time. The module provides LED indications for operating control, airflow, pilot trial for ignition, flame status, and alarm conditions. For standing-pilot applications, the MP100 can be configured according to the applicable Fireye wiring instructions.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eM-Series II Compatibility: Designed for use with Fireye Modular M-Series II flame safeguard controls.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eRelight Function: Provides automatic relight operation following an appropriate flame failure condition.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePlug-In Installation: Installs directly into the programmer position of a compatible M-Series II chassis.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eBurner Sequencing: Defines the operating sequence and timing functions of the flame safeguard control.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLED Diagnostics: Provides visual indication of operating control, airflow, PTFI, flame, and alarm status.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFuel Burner Applications: Suitable for compatible light-oil and gas-fired heating or process burners.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAmplifier Compatibility: Works with separately selected amplifier modules matched to the required flame scanner.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eM-Series Replacement: Provides a modern replacement module for compatible Fireye M-Series relight controls.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eThe MP100 delivers programmable burner sequencing, ignition supervision, and relight functionality required for compatible Fireye M-Series II combustion control applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Fireye","offers":[{"title":"Default Title","offer_id":52560794976554,"sku":"MP100","price":802.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/s-l1200_1b998065-c20f-43bf-ad52-75bdd464df99.jpg?v=1789038987","url":"https:\/\/iqelectro.com\/products\/fireye-mp100-m-series-ii-relight-programmer-module-for-burner-control","provider":"IQElectro","version":"1.0","type":"link"}