{"product_id":"fireye-sb560532aa-burner-control-120-vac-flame-safeguard-with-uv-detection","title":"Fireye SB560532AA Burner Control 120 VAC Flame Safeguard with UV Detection","description":"\u003ch4 class=\"PDq2pG_selectionAnchorContainer\"\u003eDescription\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cspan\u003eThe Fireye SB560532AA is a 120 VAC flame safeguard burner control designed to manage burner operation and provide flame monitoring. It uses UV flame detection, a 10\/15-second trial-for-ignition sequence, and no-purge operation. The unit serves as a replacement for the Fireye VF560532AA control.\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable style=\"width: 99.941%; height: 319.862px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 25.8187px;\"\u003e\n\u003ctd style=\"width: 30.7609%; height: 25.8187px;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.2616%; height: 25.8187px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 25.8187px;\"\u003e\n\u003ctd style=\"width: 30.7609%; height: 25.8187px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.2616%; height: 25.8187px;\"\u003eFireye\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 25.8187px;\"\u003e\n\u003ctd style=\"width: 30.7609%; height: 25.8187px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.2616%; height: 25.8187px;\"\u003eSafety Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 25.8187px;\"\u003e\n\u003ctd style=\"width: 30.7609%; height: 25.8187px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.2616%; height: 25.8187px;\"\u003eSB560532AA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 25.8187px;\"\u003e\n\u003ctd style=\"width: 30.7609%; height: 25.8187px;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.2616%; height: 25.8187px;\"\u003eFlame Safeguard Burner Controls\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 25.8187px;\"\u003e\n\u003ctd style=\"width: 30.7609%; height: 25.8187px;\"\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.2616%; height: 25.8187px;\"\u003eBurner Control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 25.8187px;\"\u003e\n\u003ctd style=\"width: 30.7609%; height: 25.8187px;\"\u003e\u003cstrong\u003eControl Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.2616%; height: 25.8187px;\"\u003eFlame Safeguard Control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 25.8187px;\"\u003e\n\u003ctd style=\"width: 30.7609%; height: 25.8187px;\"\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.2616%; height: 25.8187px;\"\u003e120 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 25.8187px;\"\u003e\n\u003ctd style=\"width: 30.7609%; height: 25.8187px;\"\u003e\u003cstrong\u003eTrial for Ignition (TFI)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.2616%; height: 25.8187px;\"\u003e10\/15 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 25.8187px;\"\u003e\n\u003ctd style=\"width: 30.7609%; height: 25.8187px;\"\u003e\u003cstrong\u003eFlame Detection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.2616%; height: 25.8187px;\"\u003eUV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 25.8187px;\"\u003e\n\u003ctd style=\"width: 30.7609%; height: 25.8187px;\"\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.2616%; height: 25.8187px;\"\u003eBurner Management\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 25.8562px;\"\u003e\n\u003ctd style=\"width: 30.7609%; height: 25.8562px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.2616%; height: 25.8562px;\"\u003e1.45 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About SB560532AA\u003c\/h4\u003e\n\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003e\u003cmeta charset=\"UTF-8\"\u003e\u003cspan\u003eThe SB560532AA is part of Fireye’s flame safeguard control equipment used in burner management applications. It is configured for 120 VAC systems and incorporates UV-based flame detection for monitoring burner flame conditions. The control uses a 10\/15-second TFI sequence to establish and verify flame during the ignition cycle. Its no-purge configuration makes it suitable for systems designed to operate without a pre-ignition purge sequence.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eBurner Control: Provides control functions for burner operating sequences and flame supervision.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFlame Safeguard: Monitors flame conditions as part of a burner safety control system.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e120 VAC Operation: Designed for electrical systems using a 120 VAC supply.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e10\/15-Second TFI: Provides a selectable 10- or 15-second trial-for-ignition interval.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eUV Flame Detection: Supports ultraviolet flame sensing for burner flame monitoring.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eNo-Purge Configuration: Designed for applications that operate without a pre-purge sequence.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eReplacement Compatibility: Serves as a replacement for the Fireye VF560532AA.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eApplication: Intended for burner management and flame safeguard control systems.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eThe SB560532AA delivers the reliability and precision required for burner management and flame safeguard applications.\u003c\/span\u003e\u003c\/p\u003e","brand":"Fireye","offers":[{"title":"Default Title","offer_id":52562700730666,"sku":"SB560532AA","price":3299.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/s-l1600_c86e6766-6360-43df-b2b9-3c5200f59a9a.webp?v=1789066253","url":"https:\/\/iqelectro.com\/products\/fireye-sb560532aa-burner-control-120-vac-flame-safeguard-with-uv-detection","provider":"IQElectro","version":"1.0","type":"link"}