{"product_id":"fireye-uvm-id-uvm-series-120-vac-ultraviolet-flame-safeguard-control-and-amplifier","title":"Fireye UVM-ID UVM Series 120 VAC Ultraviolet Flame Safeguard Control and Amplifier","description":"\u003ch4 class=\"PDq2pG_selectionAnchorContainer\"\u003eDescription\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003eThe Fireye UVM-ID is a legacy ultraviolet flame safeguard control designed to supervise burner flame presence and provide automatic safety response when an acceptable flame signal is not detected. Fireye part number UVM-ID operates from a 120 VAC, 50\/60 Hz supply and combines UV flame-signal amplification with burner safety control functions for industrial and commercial combustion equipment.\u003c\/p\u003e\n\u003ch3\u003e\u003cbr\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFireye\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCombustion Controls\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUVM-ID\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFlame Safeguard Controls\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFireye UVM Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUltraviolet Flame Safeguard Control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Technology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSolid-State Electronic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFlame Detection Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUltraviolet (UV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNormal Flame Test Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApprox. 4.0–5.5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTest Meter Requirement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20,000 Ohms\/Volt Meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePrimary Function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBurner Flame Supervision and Flame Failure Protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAutomatic Burner Safety Control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstallation Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWiring Base \/ Chassis Mounted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTypical Equipment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBoilers, Furnaces, Ovens, Process Heaters, Industrial Burners\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReplacement Platform\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFireye MicroM configurations available for many legacy UVM applications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApprox. 2 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About \u003cspan\u003eUVM-ID\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003eThe UVM-ID is part of Fireye’s legacy UVM Series of ultraviolet flame safeguard controls used on automatically fired burner systems. Its solid-state electronic design processes the signal from a compatible ultraviolet flame detector and supervises burner operation through ignition, flame establishment, and normal firing conditions. The UVM-ID uses the traditional Fireye UVM\/M-Series wiring-base architecture, and later Fireye MicroM configurations were developed to replace many UVM installations with little or no field rewiring. It is commonly encountered in legacy boilers, furnaces, ovens, process heaters, and packaged burner systems where maintaining compatibility with existing Fireye wiring and combustion-control equipment is important.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUltraviolet Flame Supervision: Processes signals from a compatible UV flame detector to establish burner flame presence.\u003c\/li\u003e\n\u003cli\u003eSolid-State Electronics: Uses electronic flame-signal processing rather than older electromechanical flame detection circuitry.\u003c\/li\u003e\n\u003cli\u003e120 VAC Operation: Designed for standard 120 VAC combustion-control power systems.\u003c\/li\u003e\n\u003cli\u003e50\/60 Hz Compatibility: Supports installations operating from either 50 Hz or 60 Hz AC supplies.\u003c\/li\u003e\n\u003cli\u003eFlame Failure Protection: Initiates the configured burner safety response when an acceptable flame signal is lost.\u003c\/li\u003e\n\u003cli\u003eBurner Sequencing Support: Integrates flame verification with the associated burner ignition and fuel-control sequence.\u003c\/li\u003e\n\u003cli\u003eFlame Signal Test Capability: Provides a DC test signal that can be measured during setup and troubleshooting.\u003c\/li\u003e\n\u003cli\u003e4.0–5.5 VDC Normal Test Range: Typical UVM test voltage for an established flame is approximately 4.0 to 5.5 VDC when measured with the specified meter.\u003c\/li\u003e\n\u003cli\u003eLegacy UVM Platform: Designed for established Fireye UVM flame safeguard installations and replacement applications.\u003c\/li\u003e\n\u003cli\u003eWiring Base Compatibility: Uses the Fireye wiring-base arrangement later shared with various M-Series II and MicroM configurations.\u003c\/li\u003e\n\u003cli\u003eIndustrial Burner Application: Suitable for compatible gas and oil combustion equipment requiring automatic flame supervision.\u003c\/li\u003e\n\u003cli\u003eService Replacement Use: Frequently used to maintain existing legacy burner installations without completely redesigning the flame safeguard wiring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe UVM-ID delivers the reliability and precision required for ultraviolet flame supervision and flame-failure protection in compatible legacy burner control systems.\u003c\/p\u003e\n\u003ch2\u003e\u003cbr\u003e\u003c\/h2\u003e","brand":"Fireye","offers":[{"title":"Default Title","offer_id":52596787085610,"sku":"UVM-ID","price":882.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/NEW-FIREYE-UVM-ID-FLAME-SAFETY-AMPLIFIER-UVMID-176570870782-2.png?v=1789327576","url":"https:\/\/iqelectro.com\/products\/fireye-uvm-id-uvm-series-120-vac-ultraviolet-flame-safeguard-control-and-amplifier","provider":"IQElectro","version":"1.0","type":"link"}