{"product_id":"fireye-yb110uvsc-burnerlogix-ultra-violet-self-check-flame-amplifier-module-120v","title":"Fireye YB110UVSC BurnerLogix Ultra-Violet Self-Check Flame Amplifier Module 120V","description":"\u003ch4 class=\"PDq2pG_selectionAnchorContainer\"\u003eDescription\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003eThe Fireye YB110UVSC is a BurnerLogix chassis and flame amplifier module designed for burner management systems requiring ultraviolet self-check flame monitoring. It operates from a 120 VAC supply and interfaces with compatible self-check UV scanners to provide continuous flame supervision for automatically fired burners.\u003c\/p\u003e\n\u003ch3\u003e\u003cbr\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable style=\"width: 89.9785%; height: 701.151px;\" height=\"610\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21.6375px;\"\u003e\n\u003ctd style=\"width: 49.5922%; height: 21.6375px;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 50.1659%; height: 21.6375px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21.6375px;\"\u003e\n\u003ctd style=\"width: 49.5922%; height: 21.6375px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 50.1659%; height: 21.6375px;\"\u003eFireye\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21.6375px;\"\u003e\n\u003ctd style=\"width: 49.5922%; height: 21.6375px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 50.1659%; height: 21.6375px;\"\u003eBurner Controls\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21.6375px;\"\u003e\n\u003ctd style=\"width: 49.5922%; height: 21.6375px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 50.1659%; height: 21.6375px;\"\u003eYB110UVSC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21.6375px;\"\u003e\n\u003ctd style=\"width: 49.5922%; height: 21.6375px;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 50.1659%; height: 21.6375px;\"\u003eFlame Amplifier Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21.6375px;\"\u003e\n\u003ctd style=\"width: 49.5922%; height: 21.6375px;\"\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 50.1659%; height: 21.6375px;\"\u003eChassis \/ Flame Amplifier Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21.6375px;\"\u003e\n\u003ctd style=\"width: 49.5922%; height: 21.6375px;\"\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 50.1659%; height: 21.6375px;\"\u003eBurnerLogix Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21.6375px;\"\u003e\n\u003ctd style=\"width: 49.5922%; height: 21.6375px;\"\u003e\u003cstrong\u003eAmplifier Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 50.1659%; height: 21.6375px;\"\u003eUV Self-Check\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21.6375px;\"\u003e\n\u003ctd style=\"width: 49.5922%; height: 21.6375px;\"\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 50.1659%; height: 21.6375px;\"\u003e120 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21.6375px;\"\u003e\n\u003ctd style=\"width: 49.5922%; height: 21.6375px;\"\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 50.1659%; height: 21.6375px;\"\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21.6375px;\"\u003e\n\u003ctd style=\"width: 49.5922%; height: 21.6375px;\"\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 50.1659%; height: 21.6375px;\"\u003e25 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20.6375px;\"\u003e\n\u003ctd style=\"width: 49.5922%; height: 20.6375px;\"\u003e\u003cstrong\u003eFlame Detection Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 50.1659%; height: 20.6375px;\"\u003eUltraviolet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21.6375px;\"\u003e\n\u003ctd style=\"width: 49.5922%; height: 21.6375px;\"\u003e\u003cstrong\u003eScanner Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 50.1659%; height: 21.6375px;\"\u003eSelf-Check UV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21.6375px;\"\u003e\n\u003ctd style=\"width: 49.5922%; height: 21.6375px;\"\u003e\u003cstrong\u003eCompatible Scanner Series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 50.1659%; height: 21.6375px;\"\u003eFireye 55UV5 Self-Check UV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 46.5375px;\"\u003e\n\u003ctd style=\"width: 49.5922%; height: 46.5375px;\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 50.1659%; height: 46.5375px;\"\u003e-40°F to 140°F (-40°C to 60°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 49.5922%; height: 19.5938px;\"\u003e\u003cstrong\u003eProtection Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 50.1659%; height: 19.5938px;\"\u003eNEMA 1 \/ IP01 control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 49.5922%; height: 19.5938px;\"\u003e\u003cstrong\u003eApprovals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 50.1659%; height: 19.5938px;\"\u003eUL\/cUL, FM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 49.5922%; height: 19.5938px;\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 50.1659%; height: 19.5938px;\"\u003e4.00 × 5.00 × 2.12 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 49.5922%; height: 19.5938px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 50.1659%; height: 19.5938px;\"\u003e3.2 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eInformation About \u003cspan\u003eYB110UVSC\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003eThe YB110UVSC is a BurnerLogix Y-series chassis\/flame amplifier module incorporating a UV self-check amplifier for combustion safety applications. It forms part of Fireye’s microprocessor-based BurnerLogix burner management platform and accepts interchangeable programmer and display modules for application-specific control functions. The module is designed for use with compatible Fireye self-check ultraviolet scanners, including the 55UV5 series. Its architecture combines burner sequencing interfaces with flame-signal processing to support supervised operation of gas, oil, and combination-fuel burner systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003eUV Self-Check Amplifier: Provides flame-signal processing for compatible self-check ultraviolet scanners.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eBurnerLogix Platform: Integrates with Fireye BurnerLogix Y burner management components.\u003c\/li\u003e\n\u003cli\u003e120 VAC Operation: Designed for a nominal 120 VAC, 50\/60 Hz input supply.\u003c\/li\u003e\n\u003cli\u003eScanner Compatibility: Supports compatible Fireye self-check UV scanners such as the 55UV5-1009.\u003c\/li\u003e\n\u003cli\u003eModular Configuration: Accepts compatible BurnerLogix programmer and optional display modules.\u003c\/li\u003e\n\u003cli\u003eBurner Management Integration: Supports flame supervision as part of automatic burner sequencing and safety control.\u003c\/li\u003e\n\u003cli\u003eIndustrial Temperature Range: BurnerLogix YB110 controls are specified for operation from -40°F to 140°F (-40°C to 60°C).\u003c\/li\u003e\n\u003cli\u003eSafety Approvals: The BurnerLogix Y platform carries applicable UL\/cUL and FM approvals. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe YB110UVSC delivers the reliability and precision required for self-check ultraviolet flame monitoring and burner safety control applications.\u003c\/p\u003e","brand":"Fireye","offers":[{"title":"Default Title","offer_id":52574836556074,"sku":"YB110UVSC","price":2399.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/YB110UVSC.png?v=1789145858","url":"https:\/\/iqelectro.com\/products\/fireye-yb110uvsc-burnerlogix-ultra-violet-self-check-flame-amplifier-module-120v","provider":"IQElectro","version":"1.0","type":"link"}