{"product_id":"gamewell-fci-dact-e3-alarm-communicator-in-stock","title":"DACT-E3 | Gamewell-FCI Digital Alarm Communicator Transmitter","description":"\u003ch4\u003eDescription\u003c\/h4\u003e\n\u003cp\u003eThe Gamewell-FCI DACT-E3 is a digital alarm communicator transmitter designed to deliver secure and reliable alarm signaling for fire and emergency systems. As an optional module for E3 and S3 Series control panels, it transmits alarm and status information to central monitoring stations over standard telephone networks. Engineered for dependable communication, the DACT-E3 enhances system connectivity and ensures timely reporting of critical events.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 33.443%;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.3377%;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 33.443%;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.3377%;\"\u003eGamewell-FCI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 33.443%;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.3377%;\"\u003eFlame Safety Products\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 33.443%;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.3377%;\"\u003eFlame Safety Accessory\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 33.443%;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.3377%;\"\u003eDACT-E3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 33.443%;\"\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.3377%;\"\u003eOption Card \/ Digital Alarm Communicator Transmitter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 33.443%;\"\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.3377%;\"\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 33.443%;\"\u003e\u003cstrong\u003eOperating Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.3377%;\"\u003e0.018 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 33.443%;\"\u003e\u003cstrong\u003eAlarm Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.3377%;\"\u003e0.018 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.443%;\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.3377%;\"\u003e49°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.443%;\"\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.3377%;\"\u003eUp to 93%, non-condensing at 32°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.443%;\"\u003e\u003cstrong\u003eCommunication Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.3377%;\"\u003eRS-485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.443%;\"\u003e\u003cstrong\u003eSignaling Formats\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.3377%;\"\u003eSIA 3+1, SIA 4+2, Ademco Contact ID, others\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.443%;\"\u003e\u003cstrong\u003eCompliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.3377%;\"\u003eUL 864 9th Edition, FCC Part 68\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.443%;\"\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.3377%;\"\u003eE3 System Cabinet (standoff-mounted)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.443%;\"\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.3377%;\"\u003eE3 \u0026amp; S3 Addressable Fire Alarm Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003cspan style=\"font-size: 0.875rem;\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About DACT-E3\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe DACT-E3 is an integral option card developed for use with the Gamewell-FCI E3 Series Expandable Emergency Evacuation System and S3 Series addressable fire alarm panels. This module provides digital communication over telephone lines, enabling fire alarm events, supervisory conditions, and system statuses to be transmitted directly to central monitoring stations. Utilizing a variety of industry-standard signaling formats—including SIA, Ademco Contact ID, and 4+2 protocols—the DACT-E3 ensures broad compatibility with digital alarm communicator receivers. Designed for flexible installation, the DACT-E3 can be mounted within the main system cabinet or positioned remotely via RS-485 serial communication. Its circuit design allows pre-programmed dialing, verification of central station acknowledgment tones, and proper line seizure functions for reliable message delivery. The module complies with FCC Part 68 standards and is UL 864 9th Edition listed, ensuring adherence to stringent communication and fire system requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDigital alarm transmission: Sends fire, supervisory, and system status signals to central monitoring stations.\u003c\/li\u003e\n\u003cli\u003eMulti-format compatibility: Supports SIA, Ademco Contact ID, and additional industry-standard signaling formats.\u003c\/li\u003e\n\u003cli\u003eRS-485 communication: Interfaces with E3 sub-assemblies for flexible local or remote placement.\u003c\/li\u003e\n\u003cli\u003eUL 864 9th Edition listed: Meets fire alarm communication safety and performance standards.\u003c\/li\u003e\n\u003cli\u003eAutomatic line control: Manages on\/off-hook status, line seizure, and verification of receiver acknowledgment tones.\u003c\/li\u003e\n\u003cli\u003ePre-programmed dialing: Allows stored central station phone numbers for rapid communication.\u003c\/li\u003e\n\u003cli\u003eFlexible mounting: Installs inside E3 cabinets or on standoffs depending on system layout.\u003c\/li\u003e\n\u003cli\u003eFCC-compliant design: Meets telecommunications standards for digital communicators.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe DACT-E3 delivers the reliability and precision required for critical alarm communication in modern fire protection systems.\u003c\/p\u003e","brand":"Gamewell-FCI","offers":[{"title":"Default Title","offer_id":47404230770986,"sku":"DACT-E3","price":1399.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/DACT-E3.jpg?v=1706024740","url":"https:\/\/iqelectro.com\/products\/gamewell-fci-dact-e3-alarm-communicator-in-stock","provider":"IQElectro","version":"1.0","type":"link"}