{"product_id":"gamewell-fci-ff8-fireforce-8-24-vdc-8-a-nac-expander-power-supply","title":"Gamewell-FCI FF8 FireForce 8 24 VDC 8 A NAC Expander Power Supply","description":"\u003ch4 class=\"PDq2pG_selectionAnchorContainer\"\u003eDescription\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003eGamewell-FCI FF8 FireForce 8 is a notification appliance circuit (NAC) expander and power supply designed to extend the power capacity of existing fire alarm systems. It provides regulated 24 VDC power across four NAC outputs, with a total output capacity of 8.0 A and an integral battery charger.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable style=\"width: 99.941%; height: 431.063px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 30.3465%; height: 19.5938px;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.2345%; height: 19.5938px;\"\u003eNew \/ Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 30.3465%; height: 19.5938px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.2345%; height: 19.5938px;\"\u003eGamewell-FCI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 30.3465%; height: 19.5938px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.2345%; height: 19.5938px;\"\u003eFire Safety\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 30.3465%; height: 19.5938px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.2345%; height: 19.5938px;\"\u003eFF8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 30.3465%; height: 19.5938px;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.2345%; height: 19.5938px;\"\u003eFire Alarm Power Supplies\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 30.3465%; height: 19.5938px;\"\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.2345%; height: 19.5938px;\"\u003eNAC Expander \/ Power Supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 30.3465%; height: 19.5938px;\"\u003e\u003cstrong\u003eInput Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.2345%; height: 19.5938px;\"\u003e120 VAC, 60 Hz, 3.0 A or 220 VAC, 1.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 30.3465%; height: 19.5938px;\"\u003e\u003cstrong\u003eOutput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.2345%; height: 19.5938px;\"\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 30.3465%; height: 19.5938px;\"\u003e\u003cstrong\u003eTotal Output Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.2345%; height: 19.5938px;\"\u003e8.0 A maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 30.3465%; height: 19.5938px;\"\u003e\u003cstrong\u003eNAC Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.2345%; height: 19.5938px;\"\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 30.3465%; height: 19.5938px;\"\u003e\u003cstrong\u003eMaximum NAC Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.2345%; height: 19.5938px;\"\u003e3.0 A per circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 30.3465%; height: 19.5938px;\"\u003e\u003cstrong\u003eNAC Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.2345%; height: 19.5938px;\"\u003eFour Class B, two Class A, or combined Class A\/Class B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 30.3465%; height: 39.1875px;\"\u003e\u003cstrong\u003eAuxiliary Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.2345%; height: 39.1875px;\"\u003e0.15 A standard; up to 1.5 A under specified operating conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 30.3465%; height: 19.5938px;\"\u003e\u003cstrong\u003eBattery Charger\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.2345%; height: 19.5938px;\"\u003eIntegral charger\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 30.3465%; height: 19.5938px;\"\u003e\u003cstrong\u003eBattery Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.2345%; height: 19.5938px;\"\u003e7–24 Ah batteries; charging capacity up to 26 Ah\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 30.3465%; height: 39.1875px;\"\u003e\u003cstrong\u003eEnd-of-Line Resistor Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.2345%; height: 39.1875px;\"\u003e2K–25K ohms, 1\/2 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 30.3465%; height: 19.5938px;\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.2345%; height: 19.5938px;\"\u003e32°F to 120°F (0°C to 49°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 30.3465%; height: 19.5938px;\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.2345%; height: 19.5938px;\"\u003e18.0 × 12.5 × 4.5 in (45.72 × 31.75 × 11.43 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 30.3465%; height: 19.5938px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.2345%; height: 19.5938px;\"\u003e1.36 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About \u003cspan\u003eFF8\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003eThe FF8 is designed to connect to a compatible UL-listed fire alarm control panel and provide additional notification circuit capacity. Its four outputs can be configured as four Class B circuits, two Class A circuits, or a combination of Class A and Class B circuits, with an optional Class A adapter supporting four Class A outputs. The unit provides independent supervision of its output circuits and includes an internal battery charging circuit for standby operation. The FF8 also provides auxiliary power for ancillary fire alarm devices such as remote annunciators and door holders.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eNAC Expansion: Extends the notification appliance circuit capacity of an existing fire alarm control panel.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e8 A Output Capacity: Provides up to 8.0 A total regulated 24 VDC output power.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFour NAC Outputs: Provides four independently supervised notification appliance circuits.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFlexible Class Configuration: Supports Class B, Class A, or combined Class A\/Class B output configurations.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eIntegral Battery Charger: Includes an internal charger for 24 VDC standby batteries.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAuxiliary Power: Provides power for compatible ancillary fire alarm system devices.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eRegulated Power Supply: Uses switch-mode technology to deliver filtered and electronically regulated output power.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFault Supervision: Independently supervises NAC circuits and reports circuit faults to the connected system.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eThe FF8 delivers the additional regulated power, circuit expansion, and supervision required for reliable fire alarm notification system installations.\u003c\/span\u003e\u003c\/p\u003e","brand":"Gamewell-FCI","offers":[{"title":"Default Title","offer_id":52559466135850,"sku":"FF8","price":887.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/3b43b891-0128-4001-9997-6245015b92ed.png?v=1789030430","url":"https:\/\/iqelectro.com\/products\/gamewell-fci-ff8-fireforce-8-24-vdc-8-a-nac-expander-power-supply","provider":"IQElectro","version":"1.0","type":"link"}