{"product_id":"ge-fanuc-ic694alg223-db-pacsystems-rx3i-16-channel-analog-current-input-module","title":"GE Fanuc IC694ALG223-DB PACSystems RX3i 16-Channel Analog Current Input Module","description":"\u003ch4 class=\"PDq2pG_selectionAnchorContainer\"\u003eDescription\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eThe GE Fanuc IC694ALG223-DB is a 16-channel analog current input module designed for PACSystems RX3i programmable automation controllers. It receives analog signals from industrial transmitters and field instruments, supporting selectable 0–20 mA, 4–20 mA, and enhanced 4–20 mA input ranges. Its channel configuration, alarm monitoring, and signal diagnostics allow the PLC to process analog measurements for industrial monitoring and process-control applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable style=\"width: 100.029%;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.4935%;\"\u003e\u003cstrong\u003e\u003cspan\u003eCondition\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.333%;\"\u003e\u003cspan\u003eNew\/Never Used Surplus\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.4935%;\"\u003e\u003cstrong\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.333%;\"\u003e\u003cspan\u003eGE Fanuc\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.4935%;\"\u003e\u003cstrong\u003e\u003cspan\u003eCategory\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.333%;\"\u003e\u003cspan\u003eIndustrial Automation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.4935%;\"\u003e\u003cstrong\u003e\u003cspan\u003ePart Number\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.333%;\"\u003e\u003cspan\u003eIC694ALG223-DB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.4935%;\"\u003e\u003cstrong\u003e\u003cspan\u003eSubcategory\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.333%;\"\u003e\u003cspan\u003ePLC Analog Input Modules\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.4935%;\"\u003e\u003cstrong\u003e\u003cspan\u003eProduct Series\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.333%;\"\u003e\u003cspan\u003ePACSystems RX3i\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.4935%;\"\u003e\u003cstrong\u003e\u003cspan\u003eModule Type\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.333%;\"\u003e\u003cspan\u003eAnalog Current Input Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.4935%;\"\u003e\u003cstrong\u003e\u003cspan\u003eNumber of Channels\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.333%;\"\u003e\u003cspan\u003e16 single-ended inputs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.4935%;\"\u003e\u003cstrong\u003e\u003cspan\u003eInput Signal Type\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.333%;\"\u003e\u003cspan\u003eAnalog current\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.4935%;\"\u003e\u003cstrong\u003e\u003cspan\u003eInput Current Ranges\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.333%;\"\u003e\u003cspan\u003e0–20 mA; 4–20 mA; 4–20 mA Enhanced\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.4935%;\"\u003e\u003cstrong\u003e\u003cspan\u003eChannel Configuration\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.333%;\"\u003e\u003cspan\u003eIndividually configurable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.4935%;\"\u003e\u003cstrong\u003e\u003cspan\u003eDigital Resolution\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.333%;\"\u003e\u003cspan\u003e12 bit\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.4935%;\"\u003e\u003cstrong\u003e\u003cspan\u003eUpdate Rate\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.333%;\"\u003e\u003cspan\u003e13 ms for all 16 channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.4935%;\"\u003e\u003cstrong\u003e\u003cspan\u003eInput Impedance\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.333%;\"\u003e\u003cspan\u003e250 Ω\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.4935%;\"\u003e\u003cstrong\u003e\u003cspan\u003eInput Filter Response\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.333%;\"\u003e\u003cspan\u003e19 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.4935%;\"\u003e\u003cstrong\u003e\u003cspan\u003eAccuracy at 25°C\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.333%;\"\u003e\u003cspan\u003e±0.25% of full scale\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.4935%;\"\u003e\u003cstrong\u003e\u003cspan\u003eAccuracy Over Operating Temperature\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.333%;\"\u003e\u003cspan\u003e±0.5% of full scale\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.4935%;\"\u003e\u003cstrong\u003e\u003cspan\u003eResolution at 4–20 mA\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.333%;\"\u003e\u003cspan\u003e4 µA per count\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.4935%;\"\u003e\u003cstrong\u003e\u003cspan\u003eResolution at 0–20 mA\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.333%;\"\u003e\u003cspan\u003e5 µA per count\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.4935%;\"\u003e\u003cstrong\u003e\u003cspan\u003eExternal Supply Voltage\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.333%;\"\u003e\u003cspan\u003e20–30 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.4935%;\"\u003e\u003cstrong\u003e\u003cspan\u003eBackplane Current Consumption\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.333%;\"\u003e\u003cspan\u003e120 mA at 5 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.4935%;\"\u003e\u003cstrong\u003e\u003cspan\u003eExternal Supply Current Consumption\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.333%;\"\u003e\u003cspan\u003e65 mA at 24 VDC, plus current-loop loads\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.4935%;\"\u003e\u003cstrong\u003e\u003cspan\u003eIsolation\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.333%;\"\u003e\u003cspan\u003eOptical field-to-backplane isolation; 250 VAC continuous, 1500 VAC for 1 minute\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.4935%;\"\u003e\u003cstrong\u003e\u003cspan\u003eLow-Alarm Monitoring\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.333%;\"\u003e\u003cspan\u003eAvailable on all input ranges\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.4935%;\"\u003e\u003cstrong\u003e\u003cspan\u003eOpen-Wire Detection\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.333%;\"\u003e\u003cspan\u003eSupported in enhanced 4–20 mA mode\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.4935%;\"\u003e\u003cstrong\u003e\u003cspan\u003eStatus Indicators\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.333%;\"\u003e\u003cspan\u003eModule OK and User Supply LEDs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.4935%;\"\u003e\u003cstrong\u003e\u003cspan\u003eInstallation\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.333%;\"\u003e\u003cspan\u003eAny I\/O slot in a compatible RX3i system\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.4935%;\"\u003e\u003cstrong\u003e\u003cspan\u003eRevision\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.333%;\"\u003e\u003cspan\u003eDB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.4935%;\"\u003e\u003cstrong\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.333%;\"\u003e\u003cspan\u003e1.13 lb\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInformation About\u003cmeta charset=\"utf-8\"\u003e IC694ALG223-DB\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe IC694ALG223-DB belongs to the GE Fanuc PACSystems RX3i family of high-density analog I\/O modules. It provides 16 single-ended input channels that can be individually configured through the PLC programming software. The enhanced 4–20 mA range includes low-alarm monitoring that can help identify open-wire conditions in current loops. The module also reports its operating status and external supply condition to the CPU, supporting system diagnostics and maintenance.\u003c\/p\u003e\n\u003ch4 dir=\"auto\" data-start=\"456\" data-end=\"1011\" class=\"PDq2pG_selectionAnchorContainer\"\u003eKey Features:\u003cspan\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003e16 Analog Input Channels:\u003c\/span\u003e\u003cspan\u003e Monitors up to 16 single-ended current signals.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eMultiple Input Ranges:\u003c\/span\u003e\u003cspan\u003e Supports 0–20 mA, 4–20 mA, and enhanced 4–20 mA configurations.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003e12-Bit Resolution:\u003c\/span\u003e\u003cspan\u003e Converts analog current signals into digital values for PLC processing.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eIndividual Channel Configuration:\u003c\/span\u003e\u003cspan\u003e Allows input ranges and active channels to be configured through programming software.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eOpen-Wire Detection:\u003c\/span\u003e\u003cspan\u003e Enhanced 4–20 mA operation supports low-alarm monitoring for detecting current-loop faults.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eHigh Measurement Accuracy:\u003c\/span\u003e\u003cspan\u003e Provides ±0.25% of full scale accuracy at 25°C under specified conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eInput Isolation:\u003c\/span\u003e\u003cspan\u003e Provides optical isolation between field circuits and the backplane.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eDiagnostic Indicators:\u003c\/span\u003e\u003cspan\u003e Includes module-status and external-supply indicators for operational monitoring.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eThe IC694ALG223-DB delivers the measurement capability and signal monitoring required for industrial process control, instrumentation, and analog data acquisition.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp id=\"p-rc_c7b8f4fae39e183e-25\"\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":53453620314410,"sku":"IC694ALG223-DB","price":1252.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/images_eebd5727-e2d9-4eba-9167-cfbc76bea1ca.jpg?v=1793800100","url":"https:\/\/iqelectro.com\/products\/ge-fanuc-ic694alg223-db-pacsystems-rx3i-16-channel-analog-current-input-module","provider":"IQElectro","version":"1.0","type":"link"}