{"product_id":"ge-multilin-239-an-motor-protection-relay-quick-delivery","title":"239-AN | GE Multilin Motor Protection Relay for Industrial Motor Control","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-end=\"451\" data-start=\"0\"\u003eThe GE Multilin 239-AN is a solid-state motor protection relay designed to safeguard motors against electrical and thermal faults. It provides advanced protection functions including overload, ground fault, and unbalance monitoring. The relay supports precise diagnostics and configurable settings for reliable motor operation in industrial environments.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew \/ Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGE Multilin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eContactors \u0026amp; Starters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e239-AN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSolid State Overload\/Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMotor Protection Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36 VDC isolated, active source\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunications Baud Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1200 to 12,000 bps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGround Current Conversion\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTrue RMS, 16 samples per cycle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSwitch Input Duration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 ms minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eThermal Lockout Cool Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 to 5000 minutes, programmable (±20%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eThermal Start Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSeparate start and run protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnbalance Detection Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5% to 100% \/ OFF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVentilation Requirements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIndustrial motor protection and control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About 239-AN \u003c\/h4\u003e\n\u003cp class=\"\" data-end=\"1074\" data-start=\"590\"\u003eThe 239-AN is part of the GE Multilin motor protection relay family developed for comprehensive motor monitoring and control. It is built using solid-state electronics to deliver accurate measurement, fast response, and long-term reliability without mechanical wear. The relay integrates easily with industrial motor starters and control systems through isolated communications and configurable inputs. It is commonly used in manufacturing, processing, and infrastructure applications where motor reliability and protection are critical.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong data-end=\"1102\" data-start=\"1085\"\u003eKey Features:\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSolid-state motor protection: Provides overload, short-circuit, and ground fault protection.\u003c\/li\u003e\n\u003cli\u003eTrue RMS ground current measurement: Ensures accurate fault detection using 16 samples per cycle.\u003c\/li\u003e\n\u003cli\u003eIsolated communications interface: 36 VDC isolated active source for reliable data exchange.\u003c\/li\u003e\n\u003cli\u003eProgrammable thermal modeling: Adjustable lockout cool rates from 1 to 5000 minutes.\u003c\/li\u003e\n\u003cli\u003eSeparate start and run protection: Enhances motor safety during different operating states.\u003c\/li\u003e\n\u003cli\u003eWide unbalance detection range: Adjustable from 5% to 100% or disabled as required.\u003c\/li\u003e\n\u003cli\u003eNo ventilation required: Simplifies installation in enclosed control panels.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe 239-AN delivers the reliability and precision required for industrial motor protection and monitoring applications.\u003c\/p\u003e","brand":"GE Multilin","offers":[{"title":"Default Title","offer_id":49185018511658,"sku":"239-AN","price":6959.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/239-AN.jpg?v=1724846616","url":"https:\/\/iqelectro.com\/products\/ge-multilin-239-an-motor-protection-relay-quick-delivery","provider":"IQElectro","version":"1.0","type":"link"}