{"product_id":"general-electric-sauv2-undervoltage-release-240v-ac-250v-dc-for-spectra-rms-se150-sk1200-breakers","title":"General Electric SAUV2 Undervoltage Release 240V AC 250V DC for Spectra RMS SE150-SK1200 Breakers","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-end=\"561\" data-start=\"147\"\u003eThe General Electric SAUV2 undervoltage release is an internal accessory designed to trip molded case circuit breakers when control voltage drops below a safe operating level. It operates at 240V AC or 250V DC, ensuring reliable protection in both AC and DC systems. This unit is specifically engineered for use with GE Spectra RMS circuit breakers.\u003c\/p\u003e\n\u003cp data-end=\"561\" data-start=\"147\"\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 100%; height: 333.095px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.8187%; height: 19.5938px;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.962%; height: 19.5938px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.8187%; height: 19.5938px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.962%; height: 19.5938px;\"\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.8187%; height: 19.5938px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.962%; height: 19.5938px;\"\u003eCircuit Breaker Accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.8187%; height: 19.5938px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.962%; height: 19.5938px;\"\u003eSAUV2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.8187%; height: 19.5938px;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.962%; height: 19.5938px;\"\u003eUndervoltage Releases\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.8187%; height: 19.5938px;\"\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.962%; height: 19.5938px;\"\u003eSpectra RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.8187%; height: 19.5938px;\"\u003e\u003cstrong\u003eRated Control Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.962%; height: 19.5938px;\"\u003e240V AC \/ 250V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.8187%; height: 19.5938px;\"\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.962%; height: 19.5938px;\"\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.8187%; height: 19.5938px;\"\u003e\u003cstrong\u003eCurrent Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.962%; height: 19.5938px;\"\u003e200 mA peak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.8187%; height: 19.5938px;\"\u003e\u003cstrong\u003eMounting Location\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.962%; height: 19.5938px;\"\u003eLeft pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.8187%; height: 19.5938px;\"\u003e\u003cstrong\u003eConnection Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.962%; height: 19.5938px;\"\u003e18 AWG insulated leads\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.8187%; height: 19.5938px;\"\u003e\u003cstrong\u003eCompatible Breakers\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.962%; height: 19.5938px;\"\u003eSE150 to SK1200 series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.8187%; height: 19.5938px;\"\u003e\u003cstrong\u003eInstallation Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.962%; height: 19.5938px;\"\u003eField installable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.8187%; height: 19.5938px;\"\u003e\u003cstrong\u003eApproval\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.962%; height: 19.5938px;\"\u003eUL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.8187%; height: 19.5938px;\"\u003e\u003cstrong\u003eAccessory Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.962%; height: 19.5938px;\"\u003eInternal accessory\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.8187%; height: 19.5938px;\"\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.962%; height: 19.5938px;\"\u003eLow-voltage power distribution systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.8187%; height: 19.5938px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.962%; height: 19.5938px;\"\u003e0.9 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About SAUV2\u003cbr\u003e\u003cmeta charset=\"utf-8\"\u003e\n\u003c\/h4\u003e\n\u003cp data-end=\"1168\" data-start=\"595\"\u003eThe SAUV2 is part of General Electric’s Spectra RMS accessory lineup, developed to enhance the safety and control capabilities of molded case circuit breakers. It is designed for left-pole mounting and integrates directly into SE150 through SK1200 series breakers. Featuring AC\/DC operation and field-installable configuration, it allows flexible application in various industrial and commercial systems. This undervoltage release is commonly used in power distribution environments where automatic tripping is required to prevent operation under unstable voltage conditions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong data-start=\"1085\" data-end=\"1102\"\u003eKey Features:\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1929\" data-start=\"1151\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1728\" data-start=\"1030\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1750\" data-start=\"1074\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1649\" data-start=\"1028\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1655\" data-start=\"1052\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1671\" data-start=\"1025\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1725\" data-start=\"1035\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1765\" data-start=\"1080\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1709\" data-start=\"1048\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1635\" data-start=\"1013\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1022\" data-end=\"1631\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1644\" data-start=\"1053\"\u003e\u003c\/ul\u003e\n\u003cul data-end=\"1648\" data-start=\"1051\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1008\" data-end=\"1673\"\u003e\n\u003cli data-section-id=\"6q8bet\" data-start=\"1008\" data-end=\"1105\"\u003eUndervoltage Protection: Automatically trips the breaker when voltage falls below safe limits\u003c\/li\u003e\n\u003cli data-section-id=\"mpna0d\" data-start=\"1106\" data-end=\"1179\"\u003eDual Voltage Operation: Supports 240V AC and 250V DC control circuits\u003c\/li\u003e\n\u003cli data-section-id=\"1h7qlyl\" data-start=\"1180\" data-end=\"1271\"\u003eSpectra RMS Compatibility: Designed for GE SE150 to SK1200 molded case circuit breakers\u003c\/li\u003e\n\u003cli data-section-id=\"v6i8f2\" data-start=\"1272\" data-end=\"1347\"\u003eLeft Pole Mounting: Ensures proper installation within breaker assembly\u003c\/li\u003e\n\u003cli data-section-id=\"1h51ony\" data-start=\"1348\" data-end=\"1441\"\u003eInternal Accessory Design: Integrates directly into the breaker for compact configuration\u003c\/li\u003e\n\u003cli data-section-id=\"1nqvuhg\" data-start=\"1442\" data-end=\"1525\"\u003eField Installable: Allows easy installation and replacement in existing systems\u003c\/li\u003e\n\u003cli data-section-id=\"y0h9uw\" data-start=\"1526\" data-end=\"1591\"\u003eUL Approved: Meets recognized safety and compliance standards\u003c\/li\u003e\n\u003cli data-section-id=\"9gkmsy\" data-start=\"1592\" data-end=\"1673\"\u003eInsulated Lead Connection: Uses 18 AWG leads for secure electrical connection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1675\" data-end=\"1810\"\u003eThe SAUV2 delivers the reliability and precision required for voltage monitoring and protection in molded case circuit breaker systems.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":51350768615722,"sku":"SAUV2","price":587.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/s-l1600_86ac26e4-21d7-490b-ba2a-f8ab8f18ba51.webp?v=1774989471","url":"https:\/\/iqelectro.com\/products\/general-electric-sauv2-undervoltage-release-240v-ac-250v-dc-for-spectra-rms-se150-sk1200-breakers","provider":"IQElectro","version":"1.0","type":"link"}