{"product_id":"general-electric-tey380-circuit-breaker-ships-fast","title":"TEY380 | General Electric Q-Line Type TEY 3-Pole Molded Case Circuit Breaker 80 A 480 Vac","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-start=\"396\" data-end=\"673\"\u003eThe General Electric TEY380 is a 3-pole molded case circuit breaker rated at 80 A for three-phase electrical systems. It uses thermal-magnetic trip technology to provide reliable overload and short-circuit protection in commercial and industrial applications.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 99.9752%;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.5708%;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.2918%;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.5708%;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.2918%;\"\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.5708%;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.2918%;\"\u003eCircuit Breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.5708%;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.2918%;\"\u003eTEY380\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.5708%;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.2918%;\"\u003eMolded Case Circuit Breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.5708%;\"\u003e\u003cstrong\u003eProduct Line\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.2918%;\"\u003eQ-Line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.5708%;\"\u003e\u003cstrong\u003eFrame Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.2918%;\"\u003eTEY\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.5708%;\"\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.2918%;\"\u003e80 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.5708%;\"\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.2918%;\"\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.5708%;\"\u003e\u003cstrong\u003ePhase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.2918%;\"\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.5708%;\"\u003e\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.2918%;\"\u003e277\/480 Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.5708%;\"\u003e\u003cstrong\u003eFrequency Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.2918%;\"\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.5708%;\"\u003e\u003cstrong\u003eTrip Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.2918%;\"\u003eThermal-magnetic, non-interchangeable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.5708%;\"\u003e\u003cstrong\u003eInterrupting Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.2918%;\"\u003e14 kA at 480 Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.5708%;\"\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.2918%;\"\u003eBolt-on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.5708%;\"\u003e\u003cstrong\u003eActuator Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.2918%;\"\u003ePivot \/ Toggle Handle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.5708%;\"\u003e\u003cstrong\u003eConnection Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.2918%;\"\u003eLoad lug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.5708%;\"\u003e\u003cstrong\u003eConductor Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.2918%;\"\u003eAWG 14–8 Cu \/ AWG 12–8 Al\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.5708%;\"\u003e\u003cstrong\u003eTemperature Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.2918%;\"\u003e40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.5708%;\"\u003e\u003cstrong\u003eHeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.2918%;\"\u003e5.25 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.5708%;\"\u003e\u003cstrong\u003eWidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.2918%;\"\u003e3 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.5708%;\"\u003e\u003cstrong\u003eDepth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.2918%;\"\u003e3.06 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.5708%;\"\u003e\u003cstrong\u003eMaterial\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.2918%;\"\u003ePlastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About TEY380\u003c\/h4\u003e\n\u003cp\u003eThe TEY380 is a molded case circuit breaker from General Electric’s Q-Line family, designed for dependable protection of three-phase distribution circuits. It integrates a thermal-magnetic trip unit that combines overload protection with instantaneous short-circuit response. The breaker is intended for bolt-on installation, ensuring secure mechanical and electrical connection within panelboards and switchboards. Engineered for operation at standard industrial voltages, it supports consistent performance in commercial and light industrial environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eQ-Line Type TEY design: Developed for reliable protection in three-phase power distribution systems.\u003c\/li\u003e\n\u003cli\u003eThermal-magnetic trip unit: Provides coordinated response to overload conditions and short-circuit faults.\u003c\/li\u003e\n\u003cli\u003e80 A, 3-pole configuration: Supports balanced protection of three-phase electrical loads.\u003c\/li\u003e\n\u003cli\u003e14 kA interrupting capacity: Ensures safe fault interruption at 480 Vac operating voltage.\u003c\/li\u003e\n\u003cli\u003eBolt-on mounting construction: Enables stable installation and secure electrical contact.\u003c\/li\u003e\n\u003cli\u003eToggle handle actuator: Allows clear manual ON\/OFF operation and status indication.\u003c\/li\u003e\n\u003cli\u003eCompact molded case form: Supports installation in space-efficient electrical panels.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe TEY380 delivers the reliability and precision required for consistent protection of three-phase commercial and industrial power distribution circuits.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":48749214990634,"sku":"TEY380","price":305.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/TEY380-New-1_1a3c3201-5583-470b-b684-f1d44dd280a7.webp?v=1718878775","url":"https:\/\/iqelectro.com\/products\/general-electric-tey380-circuit-breaker-ships-fast","provider":"IQElectro","version":"1.0","type":"link"}