{"product_id":"general-electric-thql2140gft-gfci-breaker-fast-shipping","title":"THQL2140GFT | General Electric 40A 2-Pole GFCI Plug-In Breaker for 240V Single-Phase Systems","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-start=\"0\" data-end=\"451\"\u003eThe General Electric THQL2140GFT is a 40A, 2-pole molded case circuit breaker designed for dependable electrical protection in single-phase systems. This breaker provides both overcurrent and ground fault protection, making it suitable for residential and commercial applications. The THQL2140GFT ensures stable performance with its thermal magnetic trip mechanism and plug-in mounting style.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 99.9744%; height: 392.014px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 41.9578%; height: 19.6007px;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.3996%; height: 19.6007px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 41.9578%; height: 19.6007px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.3996%; height: 19.6007px;\"\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 41.9578%; height: 19.6007px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.3996%; height: 19.6007px;\"\u003eCircuit Breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 41.9578%; height: 19.6007px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.3996%; height: 19.6007px;\"\u003eTHQL2140GFT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 41.9578%; height: 19.6007px;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.3996%; height: 19.6007px;\"\u003eApp\/Comm Circuit Breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 41.9578%; height: 19.6007px;\"\u003e\u003cstrong\u003eFamily\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.3996%; height: 19.6007px;\"\u003eQ-Line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 41.9578%; height: 19.6007px;\"\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.3996%; height: 19.6007px;\"\u003eTHQL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 41.9578%; height: 19.6007px;\"\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.3996%; height: 19.6007px;\"\u003e240V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 41.9578%; height: 19.6007px;\"\u003e\u003cstrong\u003eAmperage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.3996%; height: 19.6007px;\"\u003e40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 41.9578%; height: 19.6007px;\"\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.3996%; height: 19.6007px;\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 41.9578%; height: 19.6007px;\"\u003e\u003cstrong\u003ePhase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.3996%; height: 19.6007px;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 41.9578%; height: 19.6007px;\"\u003e\u003cstrong\u003eProtection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.3996%; height: 19.6007px;\"\u003eThermal Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 41.9578%; height: 19.6007px;\"\u003e\u003cstrong\u003eFunctions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.3996%; height: 19.6007px;\"\u003eLI - Long-Time and Instantaneous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 41.9578%; height: 19.6007px;\"\u003e\u003cstrong\u003eAIC Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.3996%; height: 19.6007px;\"\u003e10kA @ 120V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 41.9578%; height: 19.6007px;\"\u003e\u003cstrong\u003eConnection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.3996%; height: 19.6007px;\"\u003ePlug-In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 41.9578%; height: 19.6007px;\"\u003e\u003cstrong\u003eGround Fault Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.3996%; height: 19.6007px;\"\u003eYes (GFCI with Self-Test)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 41.9578%; height: 19.6007px;\"\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.3996%; height: 19.6007px;\"\u003eNon-Interchangeable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 41.9578%; height: 19.6007px;\"\u003e\u003cstrong\u003eListing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.3996%; height: 19.6007px;\"\u003eUL Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 41.9578%; height: 19.6007px;\"\u003e\u003cstrong\u003eTerminal Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55.3996%; height: 19.6007px;\"\u003eLoad-Side Lug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About QL2140GFT\u003c\/h4\u003e\n\u003cp data-start=\"590\" data-end=\"1074\" class=\"\"\u003eThe THQL2140GFT is a molded case circuit breaker from GE’s Q-Line family, engineered for integration into THQL-series load centers. Built with a compact, durable construction, it incorporates a plug-in design and load-side lugs for straightforward installation and wiring. It is compatible with single-phase distribution panels requiring 2-pole protection at 240 volts. Designed for environments where both overload protection and ground fault detection are critical, this breaker uses thermal magnetic trip technology combined with LI (Long-Time and Instantaneous) functions to maintain safe electrical operation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong data-start=\"1085\" data-end=\"1102\"\u003eKey Features:\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eGround Fault Protection: Integrated GFCI capability for detecting ground faults and preventing electrical hazards.\u003c\/li\u003e\n\u003cli\u003eThermal Magnetic Trip: Provides overload and short-circuit protection through dual-action trip technology.\u003c\/li\u003e\n\u003cli\u003eTwo-Pole Configuration: Supports 240V single-phase applications requiring dual-pole isolation.\u003c\/li\u003e\n\u003cli\u003ePlug-In Design: Enables fast installation into compatible Q-Line panelboards.\u003c\/li\u003e\n\u003cli\u003e10kA Interrupting Capacity: Handles fault currents up to 10kA at 120V.\u003c\/li\u003e\n\u003cli\u003eSelf-Test Function: Continuously monitors ground fault circuitry for proper operation.\u003c\/li\u003e\n\u003cli\u003eUL Listed: Meets industry standards for electrical safety and performance.\u003c\/li\u003e\n\u003cli\u003eLoad-Side Lug Terminal: Ensures secure and reliable wiring connections.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe THQL2140GFT delivers the reliability and precision required for dependable residential and commercial circuit protection.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":48744616952106,"sku":"THQL2140GFT","price":189.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/THQL2140GFT.webp?v=1718796678","url":"https:\/\/iqelectro.com\/products\/general-electric-thql2140gft-gfci-breaker-fast-shipping","provider":"IQElectro","version":"1.0","type":"link"}