{"product_id":"general-electric-thql2180-circuit-breaker-secure-packaging","title":"THQL2180 | General Electric 2 Pole Circuit Breaker","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp\u003eGeneral Electric THQL series double pole 80 ampere plug-in molded case circuit breaker with maximum voltage rating of 240V tripping method thermal magnetic and standard interrupting rating of 10 kiloampere at 120V complete with (LI) long-time and instantaneous trip functions and load side lug terminals suitable for reverse feed application.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"height: 274.313px;\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 26.7428%; height: 19px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.2572%; height: 19px;\"\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 26.7428%; height: 19px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.2572%; height: 19px;\"\u003eCircuit Breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 26.7428%; height: 19px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.2572%; height: 19px;\"\u003eTHQL2180\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 26.7428%; height: 19px;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.2572%; height: 19px;\"\u003eLoad Center Circuit Breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 26.7428%; height: 19px;\"\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.2572%; height: 19px;\"\u003eType THQL Thermal Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 26.7428%; height: 19px;\"\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.2572%; height: 19px;\"\u003eTHQL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 26.7428%; height: 19px;\"\u003e\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.2572%; height: 19px;\"\u003e120\/240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 26.7428%; height: 19px;\"\u003e\u003cstrong\u003eAmperage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.2572%; height: 19px;\"\u003e80 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 26.7428%; height: 19px;\"\u003e\u003cstrong\u003eFrequency Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.2572%; height: 19px;\"\u003e50\/60 HZ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 26.7428%; height: 19.5938px;\"\u003e\u003cstrong\u003eInterrupt Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.2572%; height: 19.5938px;\"\u003e10 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 26.7428%; height: 19.5938px;\"\u003e\u003cstrong\u003eTrip Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.2572%; height: 19.5938px;\"\u003eLong Time\/Instantaneous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 26.7428%; height: 19.5938px;\"\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.2572%; height: 19.5938px;\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 26.7428%; height: 19.5938px;\"\u003e\u003cstrong\u003ePhase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.2572%; height: 19.5938px;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 26.7428%; height: 19.5938px;\"\u003e\u003cstrong\u003eConnection Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.2572%; height: 19.5938px;\"\u003eBox Lug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.7428%;\"\u003e\u003cstrong\u003eWire Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.2572%;\"\u003e(1) 6 to 1\/0\/4 to 1\/0 AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.7428%;\"\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.2572%;\"\u003ePlug-In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.7428%;\"\u003e\u003cstrong\u003eTemperature Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.2572%;\"\u003e60 deg C\/75 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.7428%;\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.2572%;\"\u003e3-9\/32 in H x 2 in W x 2-3\/8 in D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003cspan style=\"font-size: 0.875rem;\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About THQL2180\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe General Electric THQL2180 is a 2-pole circuit breaker from the GE Q-Line series, designed to provide reliable protection for electrical systems. This molded case circuit breaker operates at 120\/240 VAC and is rated for 80 amperes, making it suitable for residential and commercial applications.\u003c\/p\u003e\n\u003cp\u003eFeaturing long-time and instantaneous trip functions, the THQL2180 offers comprehensive protection against both sustained overloads and short circuits. It has an interrupting capacity (AIC) of 10kA, ensuring safe operation by handling significant fault currents without compromising the system's integrity.\u003c\/p\u003e\n\u003cp\u003eThe breaker is designed for single-phase systems and is equipped with box lug connections, compatible with wire sizes ranging from (1) 6 AWG to 1\/0 AWG and 4 AWG to 1\/0 AWG. The plug-in mount design facilitates easy and secure installation in various panelboards.\u003c\/p\u003e\n\u003cp\u003eConstructed for durability, the THQL2180 operates effectively within a temperature range of 60°C to 75°C. Its compact dimensions—3-9\/32 inches in height, 2 inches in width, and 2-3\/8 inches in depth—allow for efficient use of space within electrical enclosures.\u003c\/p\u003e\n\u003cp\u003eOverall, the GE THQL2180 is a reliable and efficient solution for circuit protection, offering robust performance and ease of installation for a wide range of electrical applications.\u003cbr\u003e\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":48566166847786,"sku":"THQL2180","price":79.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/THQL2180.webp?v=1716893505","url":"https:\/\/iqelectro.com\/products\/general-electric-thql2180-circuit-breaker-secure-packaging","provider":"IQElectro","version":"1.0","type":"link"}