{"product_id":"general-electric-tp1616ss-power-break-i-insulated-case-circuit-breaker-with-microversatrip-plus-protection","title":"General Electric TP1616SS Power Break I Insulated Case Circuit Breaker with MicroVersaTrip Plus Protection","description":"\u003ch4 class=\"PDq2pG_selectionAnchorContainer\"\u003eDescription\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe General Electric TP1616SS is a Power Break I insulated case circuit breaker for protecting high-current industrial distribution circuits. The supplied configuration combines a 1600 A frame and trip rating with a MicroVersaTrip Plus C216LSIGR trip unit providing long-time, short-time, instantaneous, and ground-fault protection.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable style=\"width: 87.5731%; height: 454.563px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 33.8574%; height: 19.5938px;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.6934%; height: 19.5938px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 33.8574%; height: 19.5938px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.6934%; height: 19.5938px;\"\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 33.8574%; height: 19.5938px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.6934%; height: 19.5938px;\"\u003eElectrical Distribution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 33.8574%; height: 19.5938px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.6934%; height: 19.5938px;\"\u003eTP1616SS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 33.8574%; height: 19.5938px;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.6934%; height: 19.5938px;\"\u003eInsulated Case Circuit Breakers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 33.8574%; height: 19.5938px;\"\u003e\u003cstrong\u003eProduct Family\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.6934%; height: 19.5938px;\"\u003ePower Break I\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 33.8574%; height: 19.5938px;\"\u003e\u003cstrong\u003eBreaker Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.6934%; height: 19.5938px;\"\u003eTP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 33.8574%; height: 19.5938px;\"\u003e\u003cstrong\u003eFrame Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.6934%; height: 19.5938px;\"\u003e1600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 33.8574%; height: 19.5938px;\"\u003e\u003cstrong\u003eSupplied Trip Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.6934%; height: 19.5938px;\"\u003e1600 A; verify installed rating plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 33.8574%; height: 19.5938px;\"\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.6934%; height: 19.5938px;\"\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 33.8574%; height: 19.5938px;\"\u003e\u003cstrong\u003ePhase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.6934%; height: 19.5938px;\"\u003eThree-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 33.0938px;\"\u003e\n\u003ctd style=\"width: 33.8574%; height: 33.0938px;\"\u003e\u003cstrong\u003eMaximum Voltage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.6934%; height: 33.0938px;\"\u003e600 Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 33.8574%; height: 39.1875px;\"\u003e\u003cstrong\u003eSpecified Interrupting Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.6934%; height: 39.1875px;\"\u003e65 kA at 480 Vac; verify breaker nameplate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 33.8574%; height: 19.5938px;\"\u003e\u003cstrong\u003eTrip Technology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.6934%; height: 19.5938px;\"\u003eElectronic, solid-state\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 33.8574%; height: 19.5938px;\"\u003e\u003cstrong\u003eSupplied Trip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.6934%; height: 19.5938px;\"\u003eMicroVersaTrip Plus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 10px;\"\u003e\n\u003ctd style=\"width: 33.8574%; height: 10px;\"\u003e\u003cstrong\u003eTrip Unit Model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.6934%; height: 10px;\"\u003eC216LSIGR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 33.8574%; height: 39.1875px;\"\u003e\u003cstrong\u003eTrip Functions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.6934%; height: 39.1875px;\"\u003eLSIG: Long-time, short-time, instantaneous, and ground fault\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 33.8574%; height: 19.5938px;\"\u003e\u003cstrong\u003eOperator Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.6934%; height: 19.5938px;\"\u003eManual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 33.8574%; height: 19.5938px;\"\u003e\u003cstrong\u003eMounting Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.6934%; height: 19.5938px;\"\u003eStationary, bolt-on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 33.8574%; height: 19.5938px;\"\u003e\u003cstrong\u003eCase Construction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.6934%; height: 19.5938px;\"\u003eInsulated case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 33.8574%; height: 19.5938px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.6934%; height: 19.5938px;\"\u003e81 lb (36.74 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eInformation About \u003cmeta charset=\"utf-8\"\u003e\n\u003cspan data-sheets-root=\"1\"\u003eTP1616SS\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003eThe TP1616SS is part of the General Electric Power Break I family and uses a stationary, bolt-on mounting arrangement. Its three-pole construction supports coordinated interruption of compatible three-phase power circuits. The supplied unit is identified with a manually operated mechanism and a maximum voltage rating of 600 Vac. Protection settings and effective current rating depend on the installed trip unit, rating plug, and associated system configuration.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003cspan\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eHigh-Current Frame: Provides a 1600 A frame rating for compatible industrial distribution equipment.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eThree-Pole Construction: Opens three circuit poles through a common operating mechanism.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eElectronic Trip Unit: Incorporates the specified MicroVersaTrip Plus C216LSIGR programmer.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLong-Time Protection: Responds to sustained overload conditions according to the configured settings.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eShort-Time Protection: Provides delayed overcurrent response for coordination with downstream devices.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eInstantaneous Protection: Responds to sufficiently high fault currents without an intentional time delay.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eGround-Fault Protection: Provides the ground-fault function identified by the LSIG configuration.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eManual Operation: Uses a manually operated mechanism within the stationary breaker assembly.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eThe TP1616SS delivers the reliability and precision required for coordinated overcurrent and ground-fault protection in industrial power distribution systems.\u003c\/span\u003e\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":53439267373354,"sku":"TP1616SS","price":9999.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/s-l1600_6a415f72-4d47-43ac-a95a-005f0900adf7.webp?v=1793715891","url":"https:\/\/iqelectro.com\/products\/general-electric-tp1616ss-power-break-i-insulated-case-circuit-breaker-with-microversatrip-plus-protection","provider":"IQElectro","version":"1.0","type":"link"}