{"product_id":"general-electric-tqd32150-circuit-breaker-fast-shipping","title":"TQD32150 | General Electric Q-Line TQD 3-Pole 150A 240V Thermal Magnetic Circuit Breaker","description":"\u003ch4\u003eDescription\u003cstrong\u003e \u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe General Electric TQD32150 is a molded case circuit breaker designed for three-phase electrical distribution systems requiring dependable overcurrent protection. Rated for 240-volt operation with a 150-amp capacity, it supports commercial and industrial applications with consistent performance. Its thermal magnetic trip unit provides accurate long-time overload and instantaneous fault protection.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 99.9458%;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.5392%;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.3138%;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.5392%;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.3138%;\"\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.5392%;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.3138%;\"\u003eCircuit Breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.5392%;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.3138%;\"\u003eTQD32150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.5392%;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.3138%;\"\u003eMolded Case Circuit Breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.5392%;\"\u003e\u003cstrong\u003eFamily\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.3138%;\"\u003eQ-Line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.5392%;\"\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.3138%;\"\u003eTQD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.5392%;\"\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.3138%;\"\u003e240 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.5392%;\"\u003e\u003cstrong\u003eAmperage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.3138%;\"\u003e150 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.5392%;\"\u003e\u003cstrong\u003ePhase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.3138%;\"\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.5392%;\"\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.3138%;\"\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.5392%;\"\u003e\u003cstrong\u003eFunctions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.3138%;\"\u003eLI – Long-Time and Instantaneous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.5392%;\"\u003e\u003cstrong\u003eAIC Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.3138%;\"\u003e10 kA @ 240 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.5392%;\"\u003e\u003cstrong\u003eProtection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.3138%;\"\u003eThermal Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.5392%;\"\u003e\u003cstrong\u003eConnection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.3138%;\"\u003eBolt-On\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.5392%;\"\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.3138%;\"\u003eNon-Interchangeable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.5392%;\"\u003e\u003cstrong\u003eTerminals Included\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.3138%;\"\u003eLoad Side Lugs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.5392%;\"\u003e\u003cstrong\u003eInterrupting Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.3138%;\"\u003eStandard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.5392%;\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.3138%;\"\u003e40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.5392%;\"\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.3138%;\"\u003eIndustrial and commercial distribution systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eInformation About TQD32150\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe TQD32150 is a molded case circuit breaker in General Electric’s Q-Line family, engineered to provide reliable protection for three-phase systems operating at 240 volts. With a 150-amp current rating and bolt-on mounting configuration, it integrates securely into compatible panelboards, maintaining stable mechanical and electrical engagement. The breaker features a non-interchangeable thermal magnetic trip unit designed to deliver accurate long-time overload and instantaneous short-circuit response. With a 10 kA interrupt rating at 240 volts, the TQD32150 supports standard fault-clearing requirements in commercial and industrial installations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThree-pole design: Supports balanced three-phase circuit protection.\u003c\/li\u003e\n\u003cli\u003e150-amp rating: Suitable for medium-duty industrial and commercial loads.\u003c\/li\u003e\n\u003cli\u003eThermal magnetic trip: Provides dependable long-time overload and instantaneous fault protection.\u003c\/li\u003e\n\u003cli\u003e10 kA interrupt rating: Handles standard fault currents at 240 volts.\u003c\/li\u003e\n\u003cli\u003eBolt-on mounting: Ensures secure installation within Q-Line distribution equipment.\u003c\/li\u003e\n\u003cli\u003eNon-interchangeable trip unit: Delivers consistent, reliable protective performance.\u003c\/li\u003e\n\u003cli\u003eLoad-side lug terminals: Included for straightforward wiring and installation.\u003c\/li\u003e\n\u003cli\u003eDurable molded case construction: Suitable for demanding operating environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe TQD32150 delivers the reliability and precision required for safeguarding three-phase electrical systems in commercial and industrial applications.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":48554039836970,"sku":"TQD32150","price":975.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/TQD32150.webp?v=1716813005","url":"https:\/\/iqelectro.com\/products\/general-electric-tqd32150-circuit-breaker-fast-shipping","provider":"IQElectro","version":"1.0","type":"link"}