{"product_id":"hda36035-square-d-powerpact-h-35a-3-pole-i-line-thermal-magnetic-circuit-breaker","title":"HDA36035 | Square D PowerPact H 35A 3-Pole I-Line Thermal Magnetic Circuit Breaker","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-start=\"534\" data-end=\"870\"\u003eThe Square D HDA36035 is a three-pole molded case circuit breaker designed for dependable power distribution protection in commercial and industrial electrical systems. Rated at 35 amps, this breaker supports thermal-magnetic protection and I-Line style plug-in mounting for panelboard and switchboard installations. It is engineered to operate at up to 600 VAC and 250 VDC, providing reliable circuit protection across a wide range of applications.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 100%; height: 411.47px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 38.7427%;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.038%;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 38.7427%;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.038%;\"\u003eSquare D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 38.7427%;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.038%;\"\u003eCircuit Protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 38.7427%;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.038%;\"\u003eHDA36035\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 38.7427%;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.038%;\"\u003ePanelboard Circuit Breakers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 38.7427%;\"\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.038%;\"\u003eHDA (PowerPact H)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 38.7427%;\"\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.038%;\"\u003eMolded Case Circuit Breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 38.7427%;\"\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.038%;\"\u003e35 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 38.7427%;\"\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.038%;\"\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 38.7427%;\"\u003e\u003cstrong\u003ePhase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.038%;\"\u003eThree Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 38.7427%;\"\u003e\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.038%;\"\u003eUp to 600 VAC, 250 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 38.7427%;\"\u003e\u003cstrong\u003eProtection Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.038%;\"\u003eThermal-Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 38.7427%;\"\u003e\u003cstrong\u003eInterrupting Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.038%;\"\u003e14 kA @ 600 VAC, 20 kA @ 250 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 38.7427%;\"\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.038%;\"\u003eI-Line Style Plug-In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 38.7427%;\"\u003e\u003cstrong\u003eTerminal Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.038%;\"\u003eLine and Load Lugs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 38.7427%;\"\u003e\u003cstrong\u003eWire Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.038%;\"\u003eAWG 14 to AWG 3\/0 Aluminum\/Copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 38.7427%;\"\u003e\u003cstrong\u003eAmbient Operating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.038%;\"\u003eUp to 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 38.7427%;\"\u003e\u003cstrong\u003eActuator Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.038%;\"\u003eToggle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 38.7427%;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.038%;\"\u003e3.0 lb (approx.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About HDA36035\u003c\/h4\u003e\n\u003cp data-start=\"906\" data-end=\"1460\"\u003eThe HDA36035 is part of Square D’s PowerPact H (HDA series), which is designed for robust performance in Class 612 I-Line panelboards and switchboards. This circuit breaker features a thermal-magnetic trip mechanism offering long-time and instantaneous protection against overloads and short circuits. It utilizes an I-Line style plug-in connection with line and load lugs, supporting both copper and aluminum conductors across a broad wire gauge range. Built to meet multiple international standards, the breaker is suited for three-phase power distribution systems requiring consistent and compliant circuit protection.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong data-end=\"1102\" data-start=\"1085\"\u003eKey Features:\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e35 Amp Current Rating: Designed for controlled protection of three-phase branch and feeder circuits.\u003c\/li\u003e\n\u003cli\u003eThree-Pole Configuration: Provides full protection across all phases in three-phase systems.\u003c\/li\u003e\n\u003cli\u003eThermal-Magnetic Protection: Combines long-time and instantaneous trip functions for comprehensive fault response.\u003c\/li\u003e\n\u003cli\u003eI-Line Style Plug-In Connection: Enables secure and efficient installation in compatible panelboards and switchboards.\u003c\/li\u003e\n\u003cli\u003eHigh Voltage Capability: Rated for operation up to 600 VAC and 250 VDC.\u003c\/li\u003e\n\u003cli\u003eMultiple Interrupting Ratings: Provides up to 14 kA at 600 VAC and 20 kA at 250 VDC.\u003c\/li\u003e\n\u003cli\u003eWide Conductor Compatibility: Accepts aluminum or copper conductors from AWG 14 to AWG 3\/0.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe HDA36035 delivers the reliability and precision required for industrial and commercial power distribution protection.\u003c\/p\u003e","brand":"Square D","offers":[{"title":"Default Title","offer_id":51121342644522,"sku":"HDA36035","price":1427.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/s-l1600_1eeffa80-d9c2-45bd-88ae-a5d76a6fd296.webp?v=1770282481","url":"https:\/\/iqelectro.com\/products\/hda36035-square-d-powerpact-h-35a-3-pole-i-line-thermal-magnetic-circuit-breaker","provider":"IQElectro","version":"1.0","type":"link"}