{"product_id":"hfs-mm-honeywell-addressable-mini-monitor-module-15-32vdc","title":"HFS-MM | Honeywell Addressable Mini Monitor Module 15–32VDC","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-start=\"19\" data-end=\"322\"\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cmeta charset=\"utf-8\"\u003eThe Honeywell HFS-MM is an addressable mini monitor module designed to interface dry contact devices with compatible fire alarm control panels. It supervises Class B wiring circuits and transmits alarm or trouble conditions to the system. The compact design allows installation inside a single gang junction box directly behind the monitored device.\u003cbr\u003e\u003c\/p\u003e\n\u003cp data-start=\"20\" data-end=\"417\"\u003e \u003c\/p\u003e\n\u003cp data-start=\"20\" data-end=\"417\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eControls \u0026amp; Indicators\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHFS-MM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIndicator\/Display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAddressable Mini Monitor Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible Panel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModel 5600 IntelliKnight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWiring Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClass B Supervised\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal Operating Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15–32 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e375 µA max (group poll), 350 µA (direct poll)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Current (IDC Shorted)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600 µA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEOL Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e47K Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32°F–120°F (0°C–49°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10%–93% Non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.10 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About\u003cmeta charset=\"utf-8\"\u003e \u003cmeta charset=\"utf-8\"\u003e \u003cspan data-sheets-root=\"1\"\u003eHFS-MM\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp data-start=\"374\" data-end=\"870\"\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cmeta charset=\"utf-8\"\u003eThe HFS-MM is an intelligent contact input mini-module developed for use with Honeywell fire alarm systems, including the Model 5600 addressable control panel. It is engineered to monitor normally open dry contact devices such as water flow switches, supervisory switches, pull stations, and 4-wire conventional smoke detectors. The module supports Class B supervised wiring and utilizes a 47K ohm end-of-line resistor for circuit integrity monitoring. Designed for low standby current consumption, it incorporates rotary address switches for precise SLC loop addressing.\u003cbr\u003e\u003c\/p\u003e\n\u003cp data-end=\"828\" data-start=\"372\"\u003e\u003cstrong data-start=\"1085\" data-end=\"1102\"\u003eKey Features:\u003c\/strong\u003e\u003cstrong data-start=\"1085\" data-end=\"1102\"\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"998\" data-end=\"1617\"\u003e\n\u003cli data-start=\"998\" data-end=\"1092\"\u003e\n\u003cp data-start=\"1000\" data-end=\"1092\"\u003eAddressable Mini Monitor: Interfaces dry contact devices to intelligent fire alarm panels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1093\" data-end=\"1173\"\u003e\n\u003cp data-start=\"1095\" data-end=\"1173\"\u003eClass B Wiring Support: Supervises normally open initiating device circuits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1174\" data-end=\"1245\"\u003e\n\u003cp data-start=\"1176\" data-end=\"1245\"\u003eRotary Address Switches: Allows manual setting of SLC loop address.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1246\" data-end=\"1318\"\u003e\n\u003cp data-start=\"1248\" data-end=\"1318\"\u003eLow Standby Current: Optimized for reduced system power consumption.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1319\" data-end=\"1405\"\u003e\n\u003cp data-start=\"1321\" data-end=\"1405\"\u003eDry Contact Monitoring: Detects alarm and trouble conditions from contact devices.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1406\" data-end=\"1470\"\u003e\n\u003cp data-start=\"1408\" data-end=\"1470\"\u003eCompact Form Factor: Fits inside a single gang junction box.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1471\" data-end=\"1535\"\u003e\n\u003cp data-start=\"1473\" data-end=\"1535\"\u003e47K Ohm EOL Requirement: Ensures proper circuit supervision.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1536\" data-end=\"1617\"\u003e\n\u003cp data-start=\"1538\" data-end=\"1617\"\u003e15–32 VDC Operation: Compatible with standard addressable SLC voltage ranges.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1619\" data-end=\"1735\"\u003eThe HFS-MM delivers the reliability and precision required for addressable contact monitoring in fire alarm systems.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":51178127458602,"sku":"HFS-MM","price":299.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/c832a0294cec4205947cc2ea5bdb19c9.jpg?v=1771942172","url":"https:\/\/iqelectro.com\/products\/hfs-mm-honeywell-addressable-mini-monitor-module-15-32vdc","provider":"IQElectro","version":"1.0","type":"link"}