{"product_id":"hla36030-square-d-powerpact-h-frame-30a-3-pole-molded-case-circuit-breaker-600vac","title":"HLA36030 | Square D PowerPacT H-Frame 30A 3-Pole Molded Case Circuit Breaker, 600VAC","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-start=\"241\" data-end=\"732\"\u003eThe Square D HLA36030 is a PowerPacT H-frame molded case circuit breaker designed to provide dependable overcurrent protection in commercial and industrial power distribution systems. This 3-pole breaker is rated at 30 amps and up to 600 VAC, utilizing a thermal magnetic, current-limiting trip mechanism for effective overload and short-circuit protection. Built for I-Line plug-in mounting, the HLA36030 enables secure and efficient installation in compatible panelboards and switchboards.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSquare D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCircuit Breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHLA36030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries \/ Frame\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePowerPacT H-Frame\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaker Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHLA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmperage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600 VAC, 250 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThree Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal Magnetic, Current Limiting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Functions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLong-Time and Instantaneous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterrupt Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 kA @ 480 VAC, 50 kA @ 600 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContinuous Current Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eI-Line Plug-In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eI-Line Line Side \/ Lug Load Side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWire Size Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAWG 14 to AWG 3\/0 (Aluminum\/Copper)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25°C to 70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL Listed, CSA Certified, CE Marked\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H × W × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6.42 in × 4.44 in × 3.09 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.49 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About \u003cmeta charset=\"utf-8\"\u003eHLA36030\u003c\/h4\u003e\n\u003cp data-start=\"764\" data-end=\"1380\"\u003eThe HLA36030 is a Square D PowerPacT H-series circuit breaker engineered for three-phase distribution applications requiring compact, high-performance protection. It features a non-interchangeable thermal magnetic trip unit with long-time and instantaneous functions, optimized for reliable fault interruption. The breaker uses I-Line connections on the line side with mechanical lugs on the load side, allowing streamlined integration into I-Line distribution equipment. Designed to meet UL, CSA, and CE standards, it supports international installations and complies with recognized electrical safety requirements.\u003c\/p\u003e\n\u003ch3 data-start=\"1067\" data-end=\"1088\"\u003e\u003cbr\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong data-start=\"1085\" data-end=\"1102\"\u003eKey Features:\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e30 Amp Current Rating: Designed for low-current three-phase distribution circuits\u003c\/li\u003e\n\u003cli\u003e3-Pole Configuration: Supports balanced protection across three conductors\u003c\/li\u003e\n\u003cli\u003eThermal Magnetic Trip Unit: Provides long-time and instantaneous overcurrent protection\u003c\/li\u003e\n\u003cli\u003eHigh Interrupting Capacity: Rated up to 100kA at 480 VAC for robust fault handling\u003c\/li\u003e\n\u003cli\u003eI-Line Plug-In Mounting: Enables fast, secure installation in compatible systems\u003c\/li\u003e\n\u003cli\u003eCurrent-Limiting Design: Reduces peak fault energy to protect downstream equipment\u003c\/li\u003e\n\u003cli\u003eBroad Wire Compatibility: Accepts aluminum or copper conductors from AWG 14 to 3\/0\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe HLA36030 delivers the reliability and precision required for commercial and industrial power distribution protection.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51044817731882,"sku":"HLA36030","price":1278.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/HLA36030-1.png?v=1768142867","url":"https:\/\/iqelectro.com\/products\/hla36030-square-d-powerpact-h-frame-30a-3-pole-molded-case-circuit-breaker-600vac","provider":"IQElectro","version":"1.0","type":"link"}