{"product_id":"honeywell-ms-9200udls-intelligent-addressable-fire-alarm-control-panel-with-built-in-communicator","title":"Honeywell MS-9200UDLS Intelligent Addressable Fire Alarm Control Panel with Built-In Communicator","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003eThe Fire-Lite MS-9200UDLS is an addressable fire alarm control panel designed to manage detection, notification, and emergency communication in commercial and industrial facilities. It supports up to 198 addressable devices and features LiteSpeed™ protocol, integrated DACT, and four NACs for flexible system deployment.\u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable width=\"100%\" style=\"height: 765.806px; width: 100%;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 35.925px;\"\u003e\n\u003cth style=\"width: 30.0168%; text-align: left; height: 35.925px;\" class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\"\u003eCondition\u003c\/th\u003e\n\u003ctd style=\"width: 69.6188%; height: 35.925px;\" class=\"text-left text-body1 py-10 desktop:w-[60%]\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 25.275px;\"\u003e\n\u003cth style=\"width: 30.0168%; text-align: left; height: 25.275px;\" class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"width: 69.6188%; height: 25.275px;\" class=\"text-left text-body1 py-10 desktop:w-[60%]\"\u003e\u003cspan data-sheets-root=\"1\"\u003eHoneywell\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 26.4187px;\"\u003e\n\u003cth style=\"width: 30.0168%; text-align: left; height: 26.4187px;\"\u003eCategory\u003c\/th\u003e\n\u003ctd style=\"width: 69.6188%; height: 26.4187px;\"\u003e\n\u003cdiv class=\"mt-1 md:mt-0 column-left basis-2\/4 divide-y divide-rad-gray-10 border-b-[0.0625rem] border-rad-gray-10 md:border-0\"\u003e\n\u003cdiv class=\"flex gap-[1.75rem] md:gap-x-0 xl:gap-x-[1.875rem]\"\u003e\n\u003cdiv class=\"text-body-4 w-full font-light py-5 pl-4 md:py-6 md:pl-6 text-rad-gray-70\"\u003e\n\u003cdiv class=\"max-w-[8rem] break-words\"\u003e\n\u003cspan\u003eFire Safety\u003c\/span\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21.9px;\"\u003e\n\u003cth style=\"width: 30.0168%; text-align: left; height: 21.9px;\"\u003ePart Number\u003c\/th\u003e\n\u003ctd style=\"width: 69.6188%; height: 21.9px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003eMS-9200UDLS\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 24.1687px;\"\u003e\n\u003cth style=\"width: 30.0168%; text-align: left; height: 24.1687px;\"\u003e\u003cspan\u003eSubcategory\u003c\/span\u003e\u003c\/th\u003e\n\u003ctd style=\"width: 69.6188%; height: 24.1687px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan\u003eFire Alarm\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 28.6125px;\"\u003e\n\u003cth style=\"width: 30.0168%; text-align: left; height: 28.6125px;\"\u003eSystem Type\u003c\/th\u003e\n\u003ctd style=\"width: 69.6188%; height: 28.6125px;\"\u003eAddressable Fire Alarm Control Panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003cth class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\" style=\"width: 30.0168%; text-align: left; height: 39.1875px;\"\u003eDevice Capacity\u003c\/th\u003e\n\u003ctd class=\"text-left text-body1 py-10 desktop:w-[60%]\" style=\"width: 69.6188%; height: 39.1875px;\"\u003e198 addressable devices (99 detectors + 99 modules)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1687px;\"\u003e\n\u003cth style=\"width: 30.0168%; text-align: left; height: 39.1687px;\"\u003eSLC Loop Type\u003c\/th\u003e\n\u003ctd style=\"width: 69.6188%; height: 39.1687px;\"\u003eSingle loop, NFPA Style 4, 6, or 7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003cth style=\"width: 30.0168%; text-align: left; height: 39.1875px;\"\u003eNAC Outputs\u003c\/th\u003e\n\u003ctd style=\"width: 69.6188%; height: 39.1875px;\"\u003eFour Style Y (Class B), convertible to Style Z (Class A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1687px;\"\u003e\n\u003cth style=\"width: 30.0168%; text-align: left; height: 39.1687px;\"\u003ePower Supply\u003c\/th\u003e\n\u003ctd style=\"width: 69.6188%; height: 39.1687px;\"\u003e120 VAC, 60 Hz, 2.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003cth style=\"width: 30.0168%; text-align: left; height: 39.1875px;\"\u003eBackup Battery Support\u003c\/th\u003e\n\u003ctd style=\"width: 69.6188%; height: 39.1875px;\"\u003e7–18 Ah in cabinet; up to 120 Ah with external charger\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1687px;\"\u003e\n\u003cth style=\"width: 30.0168%; text-align: left; height: 39.1687px;\"\u003eDisplay\u003c\/th\u003e\n\u003ctd style=\"width: 69.6188%; height: 39.1687px;\"\u003e80-character backlit LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"width: 30.0168%; text-align: left; height: 19.5938px;\"\u003eHistory Buffer\u003c\/th\u003e\n\u003ctd style=\"width: 69.6188%; height: 19.5938px;\"\u003eStores up to 1,000 events\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"width: 30.0168%; text-align: left; height: 19.5938px;\"\u003eRelay Outputs\u003c\/th\u003e\n\u003ctd style=\"width: 69.6188%; height: 19.5938px;\"\u003eTwo programmable, one fixed trouble relay (Form-C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003cth style=\"width: 30.0168%; text-align: left; height: 39.1875px;\"\u003eCommunication Options\u003c\/th\u003e\n\u003ctd style=\"width: 69.6188%; height: 39.1875px;\"\u003eBuilt-in DACT, EIA-232, EIA-485, ANN-BUS, ACS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1687px;\"\u003e\n\u003cth style=\"width: 30.0168%; text-align: left; height: 39.1687px;\"\u003eProgramming\u003c\/th\u003e\n\u003ctd style=\"width: 69.6188%; height: 39.1687px;\"\u003eOnboard with Auto-Program “learn” mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.4px;\"\u003e\n\u003cth style=\"width: 30.0168%; text-align: left; height: 35.4px;\"\u003eClock\/Calendar\u003c\/th\u003e\n\u003ctd style=\"width: 69.6188%; height: 35.4px;\"\u003eReal-time with DST support\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003cth style=\"width: 30.0168%; text-align: left; height: 39.1875px;\"\u003eSynchronization Support\u003c\/th\u003e\n\u003ctd style=\"width: 69.6188%; height: 39.1875px;\"\u003eStrobe sync per NAC; remote sync output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"width: 30.0168%; text-align: left; height: 19.5938px;\"\u003eEnclosure Rating\u003c\/th\u003e\n\u003ctd style=\"width: 69.6188%; height: 19.5938px;\"\u003eStandard Fire-Lite enclosure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1687px;\"\u003e\n\u003cth style=\"width: 30.0168%; text-align: left; height: 39.1687px;\"\u003eCertifications\u003c\/th\u003e\n\u003ctd style=\"width: 69.6188%; height: 39.1687px;\"\u003eUL, CE, FM, NFPA 72 compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003cth style=\"width: 30.0168%; text-align: left; height: 39.1875px;\"\u003eOperating Voltage (NACs)\u003c\/th\u003e\n\u003ctd style=\"width: 69.6188%; height: 39.1875px;\"\u003e24 VDC nominal (special application rated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003cth style=\"width: 30.0168%; text-align: left; height: 39.1875px;\"\u003eMaximum NAC Current\u003c\/th\u003e\n\u003ctd style=\"width: 69.6188%; height: 39.1875px;\"\u003e2.5 A per circuit (special app), 3.0 A total; expandable to 6.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1687px;\"\u003e\n\u003cth style=\"width: 30.0168%; text-align: left; height: 39.1687px;\"\u003eWeight\u003c\/th\u003e\n\u003ctd style=\"width: 69.6188%; height: 39.1687px;\"\u003e~18–22 lbs (including batteries and cabinet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003cspan style=\"font-size: 0.875rem;\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About \u003cspan data-sheets-root=\"1\"\u003eMS-9200UDLS\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe MS-9200UDLS is a powerful and scalable Fire Alarm Control Panel (FACP) developed by Fire-Lite (Honeywell) for mid-sized addressable fire alarm systems. It features one SLC loop supporting 99 detectors and 99 modules, and operates using the LiteSpeed™ polling protocol for faster response times. The system includes built-in DACT communication, four Notification Appliance Circuits (NACs), and programmable relays. The 80-character backlit LCD screen, onboard real-time clock, 1,000-event history log, and built-in auto-program mode simplify installation and monitoring. The panel is compatible with ECC-50\/100 emergency command systems, ANN-series annunciators, and provides advanced features such as drift compensation, detector sensitivity testing, walk tests, and auto silence timers. The MS-9200UDLS complies with NFPA 72, UL, CE, and FM requirements and is designed for 120 VAC systems (MS-9200UDLSE for 220\/240 VAC).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e198 Addressable Device Capacity: Supports 99 detectors and 99 modules on a single SLC loop.\u003c\/li\u003e\n\u003cli\u003eLiteSpeed™ Protocol: Reduces polling latency and increases system responsiveness.\u003c\/li\u003e\n\u003cli\u003eIntegrated DACT: Provides built-in digital alarm communicator for remote monitoring.\u003c\/li\u003e\n\u003cli\u003eFour NAC Circuits: Four Class B (Style Y) outputs, convertible to Class A (Style Z).\u003c\/li\u003e\n\u003cli\u003eDual Relay Outputs: Two programmable relays and one fixed trouble relay for system integration.\u003c\/li\u003e\n\u003cli\u003eBacklit LCD Display: 80-character interface for clear event and programming display.\u003c\/li\u003e\n\u003cli\u003e1,000-Event History Buffer: Enables detailed diagnostics and post-event tracking.\u003c\/li\u003e\n\u003cli\u003eAdvanced Detector Functions: Supports drift compensation, sensitivity test, and auto-verification.\u003c\/li\u003e\n\u003cli\u003eInfrared and EIA Interfaces: Communication options for programming and remote printing.\u003c\/li\u003e\n\u003cli\u003eNEMA\/NFPA Compliance: Fully compliant with NFPA 72 and UL-listed fire protection standards.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe MS-9200UDLS delivers high-performance addressable fire detection and alarm control for critical life safety applications.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":50385212965162,"sku":"MS-9200UDLS","price":6397.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/d347c228877046f38e9718bf57f1a120.jpg?v=1752145708","url":"https:\/\/iqelectro.com\/products\/honeywell-ms-9200udls-intelligent-addressable-fire-alarm-control-panel-with-built-in-communicator","provider":"IQElectro","version":"1.0","type":"link"}