{"product_id":"honeywell-pgm-7240-portable-voc-gas-detector-monitor-with-pid-technology","title":"Honeywell PGM-7240 Portable VOC Gas Detector Monitor with PID Technology","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp\u003eThe PGM-7240, also known as the ppbRAE, is a compact and highly sensitive VOC monitor designed for detecting volatile organic compounds at parts-per-billion (ppb) levels. Using advanced photoionization detection (PID) technology, it delivers reliable measurements for environmental and occupational health applications. \u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable width=\"100%\" style=\"height: 920.375px; width: 100.055%;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 37.4306px;\"\u003e\n\u003cth style=\"width: 31.7658%; text-align: left; height: 37.4306px;\" class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\"\u003eCondition\u003c\/th\u003e\n\u003ctd style=\"width: 67.8175%; height: 37.4306px;\" class=\"text-left text-body1 py-10 desktop:w-[60%]\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.875px;\"\u003e\n\u003cth style=\"width: 31.7658%; text-align: left; height: 35.875px;\" class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"width: 67.8175%; height: 35.875px;\" class=\"text-left text-body1 py-10 desktop:w-[60%]\"\u003e\u003cspan data-sheets-root=\"1\"\u003eHoneywell\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 32.625px;\"\u003e\n\u003cth style=\"width: 31.7658%; text-align: left; height: 32.625px;\"\u003eCategory\u003c\/th\u003e\n\u003ctd style=\"width: 67.8175%; height: 32.625px;\"\u003e\n\u003cdiv class=\"mt-1 md:mt-0 column-left basis-2\/4 divide-y divide-rad-gray-10 border-b-[0.0625rem] border-rad-gray-10 md:border-0\"\u003e\n\u003cdiv class=\"flex gap-[1.75rem] md:gap-x-0 xl:gap-x-[1.875rem]\"\u003e\n\u003cdiv class=\"text-body-4 w-full font-light py-5 pl-4 md:py-6 md:pl-6 text-rad-gray-70\"\u003e\n\u003cdiv class=\"max-w-[8rem] break-words\"\u003e\n\u003cspan\u003e\u003c\/span\u003eSafety Systems\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 48.2222px;\"\u003e\n\u003cth style=\"width: 31.7658%; text-align: left; height: 48.2222px;\"\u003ePart Number\u003c\/th\u003e\n\u003ctd style=\"width: 67.8175%; height: 48.2222px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003ePGM-7240\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.5972px;\"\u003e\n\u003cth style=\"width: 31.7658%; text-align: left; height: 22.5972px;\"\u003e\u003cspan\u003eSubcategory\u003c\/span\u003e\u003c\/th\u003e\n\u003ctd style=\"width: 67.8175%; height: 22.5972px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan\u003eGas Monitoring System\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 44.7778px;\"\u003e\n\u003cth style=\"width: 31.7658%; text-align: left; height: 44.7778px;\"\u003eDetection Range\u003c\/th\u003e\n\u003ctd style=\"width: 67.8175%; height: 44.7778px;\"\u003e1 to 2000 ppb (VOCs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 44.7778px;\"\u003e\n\u003cth class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\" style=\"width: 31.7658%; text-align: left; height: 44.7778px;\"\u003eSensor Type\u003c\/th\u003e\n\u003ctd class=\"text-left text-body1 py-10 desktop:w-[60%]\" style=\"width: 67.8175%; height: 44.7778px;\"\u003ePhotoionization Detector (PID)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 44.7917px;\"\u003e\n\u003cth style=\"width: 31.7658%; text-align: left; height: 44.7917px;\"\u003eResponse Time\u003c\/th\u003e\n\u003ctd style=\"width: 67.8175%; height: 44.7917px;\"\u003e\u0026lt; 30 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 44.7778px;\"\u003e\n\u003cth style=\"width: 31.7658%; text-align: left; height: 44.7778px;\"\u003eAccuracy\u003c\/th\u003e\n\u003ctd style=\"width: 67.8175%; height: 44.7778px;\"\u003eHigh sensitivity for trace-level VOC detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 45.7778px;\"\u003e\n\u003cth style=\"width: 31.7658%; text-align: left; height: 45.7778px;\"\u003eBattery Type\u003c\/th\u003e\n\u003ctd style=\"width: 67.8175%; height: 45.7778px;\"\u003eRechargeable lithium-ion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 44.7778px;\"\u003e\n\u003cth style=\"width: 31.7658%; text-align: left; height: 44.7778px;\"\u003eBattery Life\u003c\/th\u003e\n\u003ctd style=\"width: 67.8175%; height: 44.7778px;\"\u003eUp to 12 hours continuous operation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 66.9306px;\"\u003e\n\u003cth style=\"width: 31.7658%; text-align: left; height: 66.9306px;\"\u003eDisplay\u003c\/th\u003e\n\u003ctd style=\"width: 67.8175%; height: 66.9306px;\"\u003eLarge graphical LCD screen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 56.0278px;\"\u003e\n\u003cth style=\"width: 31.7658%; text-align: left; height: 56.0278px;\"\u003eDatalogging Capacity\u003c\/th\u003e\n\u003ctd style=\"width: 67.8175%; height: 56.0278px;\"\u003eUp to 30,000 data points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 66.9306px;\"\u003e\n\u003cth style=\"width: 31.7658%; text-align: left; height: 66.9306px;\"\u003eHousing\u003c\/th\u003e\n\u003ctd style=\"width: 67.8175%; height: 66.9306px;\"\u003eWaterproof and dustproof\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 40.5556px;\"\u003e\n\u003cth style=\"width: 31.7658%; text-align: left; height: 40.5556px;\"\u003eOperating Temperature\u003c\/th\u003e\n\u003ctd style=\"width: 67.8175%; height: 40.5556px;\"\u003eTypically 0°C to 45°C (32°F to 113°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 40.5417px;\"\u003e\n\u003cth style=\"width: 31.7658%; text-align: left; height: 40.5417px;\"\u003eHumidity Range\u003c\/th\u003e\n\u003ctd style=\"width: 67.8175%; height: 40.5417px;\"\u003e0–95% RH (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 40.5556px;\"\u003e\n\u003cth style=\"width: 31.7658%; text-align: left; height: 40.5556px;\"\u003eCommunication Interface\u003c\/th\u003e\n\u003ctd style=\"width: 67.8175%; height: 40.5556px;\"\u003eWireless and PC (RS-232\/USB via cradle, model-dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 40.5417px;\"\u003e\n\u003cth style=\"width: 31.7658%; text-align: left; height: 40.5417px;\"\u003eSoftware Support\u003c\/th\u003e\n\u003ctd style=\"width: 67.8175%; height: 40.5417px;\"\u003eCompatible with ProRAE Studio\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 40.5417px;\"\u003e\n\u003cth style=\"width: 31.7658%; text-align: left; height: 40.5417px;\"\u003eDimensions\u003c\/th\u003e\n\u003ctd style=\"width: 67.8175%; height: 40.5417px;\"\u003eCompact handheld form factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 40.5417px;\"\u003e\n\u003cth style=\"width: 31.7658%; text-align: left; height: 40.5417px;\"\u003eCertifications\u003c\/th\u003e\n\u003ctd style=\"width: 67.8175%; height: 40.5417px;\"\u003eTypically certified for hazardous locations (model dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20.4583px;\"\u003e\n\u003cth style=\"width: 31.7658%; text-align: left; height: 20.4583px;\"\u003eWeight\u003c\/th\u003e\n\u003ctd style=\"width: 67.8175%; height: 20.4583px;\"\u003eApprox. 1.0 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003cspan style=\"font-size: 0.875rem;\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About \u003cspan data-sheets-root=\"1\"\u003ePGM-7240\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe PGM-7240 ppbRAE from RAE Systems is a portable VOC detector engineered to measure VOCs with precision down to 1 ppb, with a detection range up to 2000 ppb. Its core sensor uses a photoionization detector optimized for rapid response (under 30 seconds) and high sensitivity in industrial hygiene, hazardous waste sites, and environmental remediation projects. Designed with a rugged waterproof and dustproof housing, the unit includes a built-in lithium-ion battery for up to 12 hours of field operation and onboard memory to store up to 30,000 data points. The instrument integrates seamlessly with ProRAE Studio software for data analysis, reporting, and compliance documentation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUltra-Sensitive Detection: Measures VOCs from 1 to 2000 ppb using PID technology.\u003c\/li\u003e\n\u003cli\u003eFast Response Time: Delivers readings in less than 30 seconds for real-time monitoring.\u003c\/li\u003e\n\u003cli\u003eWireless Communication: Enables remote data transmission and integration with safety systems.\u003c\/li\u003e\n\u003cli\u003eLarge Display Screen: Easy-to-read interface enhances field usability and accuracy.\u003c\/li\u003e\n\u003cli\u003eDatalogging: Stores up to 30,000 time-stamped records for historical analysis.\u003c\/li\u003e\n\u003cli\u003eRugged Construction: Water- and dust-resistant housing withstands tough environments.\u003c\/li\u003e\n\u003cli\u003eExtended Battery Life: Operates up to 12 hours on a single rechargeable lithium-ion battery.\u003c\/li\u003e\n\u003cli\u003ePortable Design: Lightweight and compact form factor ideal for handheld use.\u003c\/li\u003e\n\u003cli\u003eSoftware Integration: Fully compatible with RAE Systems' ProRAE Studio software.\u003c\/li\u003e\n\u003cli\u003eFlexible Applications: Suitable for environmental monitoring, hazmat, and industrial hygiene.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe PGM-7240 delivers high-precision VOC monitoring and dependable field performance for safety-critical operations.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":50411807015210,"sku":"PGM-7240","price":1594.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/PGM-7240.png?v=1784222230","url":"https:\/\/iqelectro.com\/products\/honeywell-pgm-7240-portable-voc-gas-detector-monitor-with-pid-technology","provider":"IQElectro","version":"1.0","type":"link"}