{"product_id":"honeywell-r4184d1027-primary-oil-burner-control-for-intermittent-ignition-heating-systems","title":"Honeywell R4184D1027 Primary Oil Burner Control for Intermittent Ignition Heating Systems","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003eThe Honeywell R4184D1027 Primary Oil Burner Control is an electronic burner management control designed for intermittent ignition oil-fired heating systems. It supervises burner operation, ignition sequencing, and flame detection to ensure safe and reliable performance in residential and light commercial heating equipment.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"height: 176.4px; width: 100%;\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 27.4123%;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.3684%;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 27.4123%;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.3684%;\"\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 27.4123%;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.3684%;\"\u003eHVAC Controls\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 27.4123%;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.3684%;\"\u003eR4184D1027\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 27.4123%;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.3684%;\"\u003ePrimary Oil Burner Controls\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.4123%;\"\u003e\u003cstrong\u003eControl Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.3684%;\"\u003ePrimary Oil Burner Control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.4123%;\"\u003e\u003cstrong\u003eIgnition Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.3684%;\"\u003eIntermittent Ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.4123%;\"\u003e\u003cstrong\u003eFlame Detection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.3684%;\"\u003eCadmium Sulfide (Cad Cell) Flame Sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.4123%;\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.3684%;\"\u003e120 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.4123%;\"\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.3684%;\"\u003eResidential and Light Commercial Oil Burners\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.4123%;\"\u003e\u003cstrong\u003eControlled Devices\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.3684%;\"\u003eBurner Motor, Ignition Transformer, Optional Oil Valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.4123%;\"\u003e\u003cstrong\u003eSafety Feature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.3684%;\"\u003eManual Reset Safety Lockout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.4123%;\"\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.3684%;\"\u003eStandard 4 in × 4 in Junction Box\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.4123%;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.3684%;\"\u003e1.14 lb (0.52 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003cspan style=\"font-size: 0.875rem;\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About R4184D1027\u003c\/h4\u003e\n\u003cp\u003eThe Honeywell R4184D1027 is a primary oil burner control designed for intermittent ignition systems used in residential and light commercial oil-fired heating applications. It regulates the operation of the burner, ignition transformer, and optional oil valve in response to a call for heat, ensuring safe and efficient burner function. The unit features cad cell flame detection and a manual reset safety switch for lockout conditions, enhancing system safety and compliance.\u003c\/p\u003e\n\u003ch4\u003eKey Features:\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eApplication: Controls oil burner, ignition transformer, and optional oil valve for intermittent ignition systems\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eFlame Detection: Uses cadmium sulfide (cad cell) sensor to verify flame presence\u003c\/li\u003e\n\u003cli\u003eSafety Lockout: Manual reset required after safety lockout for enhanced protection\u003c\/li\u003e\n\u003cli\u003eMounting: Designed for installation on standard 4\" x 4\" junction box\u003c\/li\u003e\n\u003cli\u003eVoltage: 120V AC\u003c\/li\u003e\n\u003cli\u003eCycle Type: Intermittent ignition only\u003c\/li\u003e\n\u003cli\u003eControl Reset: Manual reset pushbutton on faceplate\u003c\/li\u003e\n\u003cli\u003eEnclosure: Compact and durable steel housing\u003c\/li\u003e\n\u003cli\u003eWiring Terminals: Screw terminals for easy installation\u003c\/li\u003e\n\u003cli\u003eDimensions: Compact footprint suitable for space-limited installations\u003c\/li\u003e\n\u003cli\u003eWeight: 1.14 lbs (0.52 kg)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe Honeywell R4184D1027 is a reliable and time-tested solution for controlling oil burner systems. Its simple installation, flame-sensing capability, and built-in safety lockout make it a preferred choice for maintaining safe and dependable heating operations.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":50376200716586,"sku":"R4184D1027","price":1058.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/e3ffc0758681472891131e2ee027ac81.jpg?v=1751916698","url":"https:\/\/iqelectro.com\/products\/honeywell-r4184d1027-primary-oil-burner-control-for-intermittent-ignition-heating-systems","provider":"IQElectro","version":"1.0","type":"link"}