{"product_id":"honeywell-r7847c1005-dynamic-self-check-flame-amplifier-module","title":"Honeywell R7847C1005 Dynamic Self-Check Flame Amplifier Module","description":"\u003ch4 class=\"PDq2pG_selectionAnchorContainer\"\u003eDescription\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp dir=\"auto\" data-start=\"16\" data-end=\"442\" class=\"PDq2pG_selectionAnchorContainer\"\u003eThe Honeywell R7847C1005 is a 7800 Series flame amplifier designed for use with Honeywell burner-management relay modules. It is a dynamic self-check amplifier intended for C7012E and C7012F ultraviolet flame detectors and provides a 2–3 second flame-failure response time.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable style=\"width: 70%; height: 529.2px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 45.2555%;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 54.2044%;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 45.2555%;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 54.2044%;\"\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 45.2555%;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 54.2044%;\"\u003eHVAC \u0026amp; Burner Controls\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 45.2555%;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 54.2044%;\"\u003eR7847C1005\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 45.2555%;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 54.2044%;\"\u003eFlame Amplifiers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 45.2555%;\"\u003e\u003cstrong\u003eDevice Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 54.2044%;\"\u003eDynamic Self-Check Flame Amplifier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 45.2555%;\"\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 54.2044%;\"\u003e7800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 45.2555%;\"\u003e\u003cstrong\u003eFlame Detection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 54.2044%;\"\u003eUltraviolet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 45.2555%;\"\u003e\u003cstrong\u003eCompatible Flame Detector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 54.2044%;\"\u003eC7012E, C7012F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 45.2555%;\"\u003e\u003cstrong\u003eFlame Failure Response Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 54.2044%;\"\u003e2.0–3.0 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 45.2555%;\"\u003e\u003cstrong\u003eSelf-Checking\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 54.2044%;\"\u003eDynamic Self-Check\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 45.2555%;\"\u003e\u003cstrong\u003eCompatible Controls\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 54.2044%;\"\u003eHoneywell 7800 Series Relay Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 45.2555%;\"\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 54.2044%;\"\u003ePlug-In PCB Edge Connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 45.2555%;\"\u003e\u003cstrong\u003eColor Identification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 54.2044%;\"\u003eGreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 45.2555%;\"\u003e\u003cstrong\u003eApprovals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 54.2044%;\"\u003eUL, CSA, Factory Mutual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 45.2555%;\"\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 54.2044%;\"\u003eMexico\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 45.2555%; height: 19.6px;\"\u003e\u003cstrong\u003eExternal Sensor Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 54.2044%; height: 19.6px;\"\u003e20 VDC ±10%, 75 mA max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 45.2555%; height: 19.6px;\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 54.2044%; height: 19.6px;\"\u003e32°F to 122°F \/ 0°C to 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 45.2555%; height: 19.6px;\"\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 54.2044%; height: 19.6px;\"\u003e5–95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 45.2555%; height: 19.6px;\"\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 54.2044%; height: 19.6px;\"\u003ePanel \/ DIN Rail \/ Field\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 45.2555%; height: 19.6px;\"\u003e\u003cstrong\u003eStatus Indicator\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 54.2044%; height: 19.6px;\"\u003eLED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 45.2555%; height: 19.6px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 54.2044%; height: 19.6px;\"\u003e0.185 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eInformation About R7847C1005\u003c\/h4\u003e\n\u003cp dir=\"auto\" data-start=\"466\" data-end=\"949\" class=\"PDq2pG_selectionAnchorContainer\"\u003eThe R7847C1005 is a plug-in flame amplifier for Honeywell 7800 Series primary safety controls. It uses dynamic self-check technology to monitor the flame-detection system and is specifically matched with C7012E\/F ultraviolet flame detectors. Honeywell documentation identifies a 2.0–3.0 second flame-failure response time for this amplifier. The module is designed to be installed in the compatible relay module through a keyed printed-circuit-board edge connector.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1291\" data-end=\"2127\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"703\" data-end=\"1384\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"730\" data-end=\"1339\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1105\" data-end=\"1892\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1027\" data-end=\"1844\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1022\" data-end=\"1720\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"964\" data-end=\"1745\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"895\" data-end=\"1639\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"999\" data-end=\"1761\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"937\" data-end=\"1684\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"865\" data-end=\"1570\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"959\" data-end=\"1674\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"968\" data-end=\"1715\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1019\" data-end=\"1782\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"873\" data-end=\"1681\"\u003e\n\u003cli data-section-id=\"1bl4esl\" data-start=\"873\" data-end=\"967\"\u003eFlame Amplifier: Provides flame-signal processing for Honeywell 7800 Series burner controls.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1vslpo1\" data-start=\"968\" data-end=\"1061\"\u003eDynamic Self-Check: Continuously checks the flame-detection system and amplifier operation.\u003c\/li\u003e\n\u003cli data-section-id=\"p79i7n\" data-start=\"1062\" data-end=\"1159\"\u003eUV Detector Compatibility: Designed for use with C7012E and C7012F ultraviolet flame detectors.\u003c\/li\u003e\n\u003cli data-section-id=\"cxfowu\" data-start=\"1160\" data-end=\"1257\"\u003e2–3 Second FFRT: Provides a specified flame-failure response time of approximately 2–3 seconds.\u003c\/li\u003e\n\u003cli data-section-id=\"374y8n\" data-start=\"1258\" data-end=\"1334\"\u003ePlug-In Design: Installs directly into compatible Honeywell relay modules.\u003c\/li\u003e\n\u003cli data-section-id=\"ht166l\" data-start=\"1335\" data-end=\"1422\"\u003eKeyed Connector: Uses a keyed PCB edge connector to help ensure correct installation.\u003c\/li\u003e\n\u003cli data-section-id=\"1bs0znk\" data-start=\"1423\" data-end=\"1526\"\u003eDiagnostic Monitoring: Supports flame-signal monitoring through the compatible burner-control system.\u003c\/li\u003e\n\u003cli data-section-id=\"1bqqpjl\" data-start=\"1527\" data-end=\"1681\"\u003eGreen Identification: Honeywell documentation identifies the dynamic self-check amplifier with green color coding. \u003cspan class=\"contents\" data-content-reference-start=\"1638\" data-content-reference-end=\"1658\"\u003e\u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"auto\" data-start=\"1683\" data-end=\"1821\"\u003eThe R7847C1005 provides the flame-signal amplification and dynamic monitoring required for compatible Honeywell burner-management systems.\u003c\/p\u003e\n\u003cp id=\"p-rc_c7b8f4fae39e183e-25\"\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52785879744810,"sku":"R7847C1005","price":825.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/shopping_1_709d3092-ce22-40a0-a35e-23ebe6bdb241.webp?v=1790593739","url":"https:\/\/iqelectro.com\/products\/honeywell-r7847c1005-dynamic-self-check-flame-amplifier-module","provider":"IQElectro","version":"1.0","type":"link"}