{"product_id":"honeywell-w7752d2007-excel-10-fan-coil-unit-controller-230vac","title":"Honeywell W7752D2007 Excel 10 Fan Coil Unit Controller 230VAC","description":"\u003ch4 class=\"PDq2pG_selectionAnchorContainer\"\u003eDescription\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp dir=\"auto\" data-start=\"16\" data-end=\"369\"\u003eThe Honeywell W7752D2007 is an Excel 10 Fan Coil Unit (FCU) Controller designed for HVAC room-temperature control in two-pipe and four-pipe fan-coil systems. It operates from 230 VAC and includes an electric reheat relay, while supporting single-, two-, or three-speed fan control and a LonWorks network connection. \u003cspan class=\"contents\" data-content-reference-start=\"332\" data-content-reference-end=\"365\"\u003e\u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable style=\"width: 70%; height: 450.736px;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 36.818%;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.8975%;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 36.818%;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.8975%;\"\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 36.818%;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.8975%;\"\u003eHVAC \u0026amp; Building Automation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 36.818%;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.8975%;\"\u003eW7752D2007\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 36.818%;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.8975%;\"\u003eFan Coil Unit Controllers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 36.818%;\"\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.8975%;\"\u003eExcel 10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 36.818%;\"\u003e\u003cstrong\u003eDevice Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.8975%;\"\u003eFan Coil Unit Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 36.818%;\"\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.8975%;\"\u003eHVAC \/ Fan Coil Units\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 36.818%;\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.8975%;\"\u003e230 VAC (+10% \/ -15%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 36.818%;\"\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.8975%;\"\u003eLonWorks \/ Echelon E-Bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 36.818%;\"\u003e\u003cstrong\u003eNetwork Speed\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.8975%;\"\u003eUp to 78 kbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 36.818%;\"\u003e\u003cstrong\u003eHeating\/Cooling\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.8975%;\"\u003eUp to 3 Heat \/ 3 Cool\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 36.818%;\"\u003e\u003cstrong\u003eSystem Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.8975%;\"\u003e2-Pipe or 4-Pipe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 36.818%;\"\u003e\u003cstrong\u003eAnalog Inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.8975%;\"\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 36.818%;\"\u003e\u003cstrong\u003eDigital Inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.8975%;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 36.818%;\"\u003e\u003cstrong\u003eAnalog Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.8975%;\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 36.818%;\"\u003e\u003cstrong\u003eDigital Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.8975%;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 36.818%;\"\u003e\u003cstrong\u003eFan Control\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.8975%;\"\u003e3-Speed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 36.818%;\"\u003e\u003cstrong\u003eElectric Reheat Relay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.8975%;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 36.818%;\"\u003e\u003cstrong\u003eReheat Relay Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.8975%;\"\u003e250 VAC \/ 10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 36.818%;\"\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.8975%;\"\u003ePanel or 35 mm DIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 36.818%;\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.8975%;\"\u003e0°C to 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 36.818%;\"\u003e\u003cstrong\u003eHumidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.8975%;\"\u003e5–95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 36.818%;\"\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.8975%;\"\u003eUL916, EN50081-1, EN50082-1, FCC Part 15 Class B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 36.818%;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.8975%;\"\u003e1.81 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eInformation About W7752D2007\u003c\/h4\u003e\n\u003cp dir=\"auto\" data-start=\"402\" data-end=\"876\" class=\"PDq2pG_selectionAnchorContainer\"\u003eThe W7752D2007 is a Honeywell Excel 10 fan-coil controller intended for systems with up to three heating and three cooling stages. It provides three analog inputs, one digital input, two analog outputs, and fan\/reheat relay outputs for controlling HVAC equipment. The controller can operate independently or communicate over Honeywell's Echelon LonWorks bus. It can be mounted on a panel or standard 35 mm DIN rail.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1291\" data-end=\"2127\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"703\" data-end=\"1384\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"730\" data-end=\"1339\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1105\" data-end=\"1892\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1027\" data-end=\"1844\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1022\" data-end=\"1720\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"964\" data-end=\"1745\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"895\" data-end=\"1639\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"999\" data-end=\"1761\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"937\" data-end=\"1684\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"865\" data-end=\"1570\"\u003e\n\u003cli data-section-id=\"qrmvl7\" data-start=\"865\" data-end=\"963\"\u003eFan Coil Control: Provides room-temperature control for two-pipe and four-pipe fan-coil systems.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"g2198t\" data-start=\"964\" data-end=\"1019\"\u003e230 VAC Power: Designed for 230 VAC supply operation.\u003c\/li\u003e\n\u003cli data-section-id=\"b3gowr\" data-start=\"1020\" data-end=\"1105\"\u003eElectric Reheat Relay: Includes a dedicated relay for electric reheat applications.\u003c\/li\u003e\n\u003cli data-section-id=\"191lute\" data-start=\"1106\" data-end=\"1182\"\u003eThree-Speed Fan Control: Supports low, medium, and high fan-speed control.\u003c\/li\u003e\n\u003cli data-section-id=\"l146tl\" data-start=\"1183\" data-end=\"1246\"\u003eHeating and Cooling: Supports up to 3 heat and 3 cool stages.\u003c\/li\u003e\n\u003cli data-section-id=\"1fgpn6o\" data-start=\"1247\" data-end=\"1329\"\u003eLonWorks Communication: Supports communication through the Echelon LonWorks bus.\u003c\/li\u003e\n\u003cli data-section-id=\"w9rnjd\" data-start=\"1330\" data-end=\"1443\"\u003eFlexible Actuator Control: Supports multiple actuator control types, including floating and PWM configurations.\u003c\/li\u003e\n\u003cli data-section-id=\"yevceq\" data-start=\"1444\" data-end=\"1570\"\u003eDIN-Rail Mounting: Can be mounted on a standard 35 mm DIN rail or directly to a panel. \u003cspan class=\"contents\" data-content-reference-start=\"1526\" data-content-reference-end=\"1558\"\u003e\u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"auto\" data-start=\"1572\" data-end=\"1700\"\u003eThe W7752D2007 provides the control and communication functions required for fan-coil HVAC and building-automation applications.\u003c\/p\u003e\n\u003cp id=\"p-rc_c7b8f4fae39e183e-25\"\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52783149220138,"sku":"W7752D2007","price":692.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/honeywell__56840.1781319367.jpg?v=1790586532","url":"https:\/\/iqelectro.com\/products\/honeywell-w7752d2007-excel-10-fan-coil-unit-controller-230vac","provider":"IQElectro","version":"1.0","type":"link"}