{"product_id":"honeywell-w973b1016-solid-state-logic-hvac-control-panel-24vac-multi-stage-heating-cooling-controller","title":"Honeywell W973B1016 Solid State Logic HVAC Control Panel 24VAC Multi-Stage Heating Cooling Controller","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003eThe Honeywell W973B1016 is a solid-state logic control panel used for regulating heating, cooling, and economizer functions in commercial HVAC systems. Designed for single-zone control, it supports multi-stage on\/off heating and cooling operations and integrates with economizer valve modulation.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable width=\"100%\" style=\"height: 448.347px; width: 100%;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 27.5694px;\"\u003e\n\u003cth style=\"width: 27.4944%; text-align: left; height: 27.5694px;\" class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\"\u003eCondition\u003c\/th\u003e\n\u003ctd style=\"width: 72.1413%; height: 27.5694px;\" class=\"text-left text-body1 py-10 desktop:w-[60%]\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.0278px;\"\u003e\n\u003cth style=\"width: 27.4944%; text-align: left; height: 22.0278px;\" class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"width: 72.1413%; height: 22.0278px;\" class=\"text-left text-body1 py-10 desktop:w-[60%]\"\u003e\u003cspan data-sheets-root=\"1\"\u003eHoneywell\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 24.875px;\"\u003e\n\u003cth style=\"width: 27.4944%; text-align: left; height: 24.875px;\"\u003eCategory\u003c\/th\u003e\n\u003ctd style=\"width: 72.1413%; height: 24.875px;\"\u003e\n\u003cdiv class=\"mt-1 md:mt-0 column-left basis-2\/4 divide-y divide-rad-gray-10 border-b-[0.0625rem] border-rad-gray-10 md:border-0\"\u003e\n\u003cdiv class=\"flex gap-[1.75rem] md:gap-x-0 xl:gap-x-[1.875rem]\"\u003e\n\u003cdiv class=\"text-body-4 w-full font-light py-5 pl-4 md:py-6 md:pl-6 text-rad-gray-70\"\u003e\n\u003cdiv class=\"max-w-[8rem] break-words\"\u003e\n\u003cspan\u003e\u003c\/span\u003e\u003cspan\u003eHVAC\u003c\/span\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 25.6944px;\"\u003e\n\u003cth style=\"width: 27.4944%; text-align: left; height: 25.6944px;\"\u003ePart Number\u003c\/th\u003e\n\u003ctd style=\"width: 72.1413%; height: 25.6944px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003eW973B1016\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20.4028px;\"\u003e\n\u003cth style=\"width: 27.4944%; text-align: left; height: 20.4028px;\"\u003e\u003cspan\u003eSubcategory\u003c\/span\u003e\u003c\/th\u003e\n\u003ctd style=\"width: 72.1413%; height: 20.4028px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan\u003eHVAC Control System Board\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1806px;\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2712\" data-start=\"2684\" style=\"width: 27.4944%;\"\u003e\u003cstrong data-end=\"2694\" data-start=\"2686\"\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"2761\" data-start=\"2712\" style=\"width: 72.1413%;\"\u003eSolid-State Logic Control Panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 36.9028px;\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2790\" data-start=\"2762\" style=\"width: 27.4944%;\"\u003e\u003cstrong data-end=\"2775\" data-start=\"2764\"\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"2839\" data-start=\"2790\" style=\"width: 72.1413%;\"\u003e24 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 36.9028px;\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2868\" data-start=\"2840\" style=\"width: 27.4944%;\"\u003e\u003cstrong data-end=\"2855\" data-start=\"2842\"\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"2917\" data-start=\"2868\" style=\"width: 72.1413%;\"\u003e50 \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1806px;\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2946\" data-start=\"2918\" style=\"width: 27.4944%;\"\u003e\u003cstrong data-end=\"2941\" data-start=\"2920\"\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"2995\" data-start=\"2946\" style=\"width: 72.1413%;\"\u003e8 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5972px;\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"3024\" data-start=\"2996\" style=\"width: 27.4944%;\"\u003e\u003cstrong data-end=\"3018\" data-start=\"2998\"\u003eControl Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"3073\" data-start=\"3024\" style=\"width: 72.1413%;\"\u003e3 heat \/ 3 cool stages (expandable to 10)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5972px;\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"3102\" data-start=\"3074\" style=\"width: 27.4944%;\"\u003e\u003cstrong data-end=\"3091\" data-start=\"3076\"\u003eOutput Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"3151\" data-start=\"3102\" style=\"width: 72.1413%;\"\u003eStaged On\/Off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5972px;\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"3180\" data-start=\"3152\" style=\"width: 27.4944%;\"\u003e\u003cstrong data-end=\"3179\" data-start=\"3154\"\u003eCompatible Thermostat\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"3229\" data-start=\"3180\" style=\"width: 72.1413%;\"\u003eT7067 with Q667 subbase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5972px;\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"3258\" data-start=\"3230\" style=\"width: 27.4944%;\"\u003e\u003cstrong data-end=\"3248\" data-start=\"3232\"\u003eSensor Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"3307\" data-start=\"3258\" style=\"width: 72.1413%;\"\u003eC7046A discharge air sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 23.4167px;\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"3336\" data-start=\"3308\" style=\"width: 27.4944%;\"\u003e\u003cstrong data-end=\"3335\" data-start=\"3310\"\u003eElectrical Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"3385\" data-start=\"3336\" style=\"width: 72.1413%;\"\u003e1\/4 in. quick-connect male terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"3414\" data-start=\"3386\" style=\"width: 27.4944%;\"\u003e\u003cstrong data-end=\"3412\" data-start=\"3388\"\u003eOperating Temp Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"3463\" data-start=\"3414\" style=\"width: 72.1413%;\"\u003e-40°F to +150°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"3492\" data-start=\"3464\" style=\"width: 27.4944%;\"\u003e\u003cstrong data-end=\"3489\" data-start=\"3466\"\u003eShipping Temp Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"3541\" data-start=\"3492\" style=\"width: 72.1413%;\"\u003e-30°F to +150°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"3570\" data-start=\"3542\" style=\"width: 27.4944%;\"\u003e\u003cstrong data-end=\"3558\" data-start=\"3544\"\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"3619\" data-start=\"3570\" style=\"width: 72.1413%;\"\u003e6.25\" H × 4.13\" W × 2.31\" D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"3648\" data-start=\"3620\" style=\"width: 27.4944%;\"\u003e\u003cstrong data-end=\"3637\" data-start=\"3622\"\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"3697\" data-start=\"3648\" style=\"width: 72.1413%;\"\u003eRooftop Units, Furnaces, Heat Pumps, Splits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"3726\" data-start=\"3698\" style=\"width: 27.4944%;\"\u003e\u003cstrong data-end=\"3716\" data-start=\"3700\"\u003eDiscontinued\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"3775\" data-start=\"3726\" style=\"width: 72.1413%;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"3804\" data-start=\"3776\" style=\"width: 27.4944%;\"\u003e\u003cstrong data-end=\"3788\" data-start=\"3778\"\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"3853\" data-start=\"3804\" style=\"width: 72.1413%;\"\u003e1.63 lbs (approx. 0.74 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003cspan style=\"font-size: 0.875rem;\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About \u003cspan data-sheets-root=\"1\"\u003eW973B1016\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe W973B1016 is part of Honeywell’s W973 control system line and is engineered for packaged rooftop units, heat pump systems, furnaces, and split systems. It operates on 24 VAC at 50\/60 Hz and consumes 8 VA, offering compatibility with T7067 thermostats and C7046A discharge sensors. This controller can manage up to three on-off heat or cool stages directly and can expand control up to ten stages when combined with W975 Satellite Sequencers. Its features include stage cycling upon power interruption and automatic sequencing upon power restoration, making it well-suited for demanding commercial environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFlexible HVAC Control: Supports control of heating, cooling, and economizer operations in various commercial systems.\u003c\/li\u003e\n\u003cli\u003eMulti-Stage Operation: Manages up to 3 stages directly or up to 10 when paired with W975 Satellite Sequencers.\u003c\/li\u003e\n\u003cli\u003eEconomizer Integration: Provides modulating DC output to control heating or cooling valve motors.\u003c\/li\u003e\n\u003cli\u003eSensor Compatibility: Works with T7067 thermostats and C7046A discharge air sensors for input and limit functions.\u003c\/li\u003e\n\u003cli\u003ePower Cycling Logic: All stages turn off on power loss and re-sequence on recovery with inter-stage delay.\u003c\/li\u003e\n\u003cli\u003eRugged Design: Operates across a wide ambient range from -40°F to +150°F for tough HVAC environments.\u003c\/li\u003e\n\u003cli\u003eCompact Panel Size: Designed for easy mounting in standard HVAC enclosures.\u003c\/li\u003e\n\u003cli\u003eDiscontinued Unit: No longer in production, but remains crucial for legacy system support.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe W973B1016 delivers dependable multi-stage HVAC control in commercial systems requiring temperature precision and integrated economizer functionality.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":50371509027114,"sku":"W973B1016","price":1944.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/s-l1600_149f4138-2333-45d5-879a-3f107689923e.webp?v=1753431017","url":"https:\/\/iqelectro.com\/products\/honeywell-w973b1016-solid-state-logic-hvac-control-panel-24vac-multi-stage-heating-cooling-controller","provider":"IQElectro","version":"1.0","type":"link"}