{"product_id":"honeywell-xd-505a-c-bus-communication-submodule-for-excel-5000-controllers","title":"Honeywell XD-505A C-Bus Communication Submodule for Excel 5000 Controllers","description":"\u003ch4 class=\"PDq2pG_selectionAnchorContainer\"\u003eDescription\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp dir=\"auto\" data-start=\"16\" data-end=\"378\" class=\"PDq2pG_selectionAnchorContainer\"\u003eThe Honeywell XD-505A is a standard C-Bus communications submodule designed for Honeywell Excel 5000-series building automation controllers. It provides C-Bus communication at 9,600 bit\/s and is installed as a plug-in submodule on compatible controller boards such as the XC 5010B, XC 6010, XL 100B, XM 100A D1, and XPC 500. \u003cspan class=\"contents\" data-content-reference-start=\"341\" data-content-reference-end=\"374\"\u003e\u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable style=\"width: 70%; height: 450.736px;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 43.4658%;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.2498%;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 43.4658%;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.2498%;\"\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 43.4658%;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.2498%;\"\u003eHVAC \u0026amp; Building Automation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 43.4658%;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.2498%;\"\u003eXD-505A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 43.4658%;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.2498%;\"\u003eCommunication Submodules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 43.4658%;\"\u003e\u003cstrong\u003eDevice Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.2498%;\"\u003eC-Bus Communication Submodule\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 43.4658%;\"\u003e\u003cstrong\u003eCommunication Bus\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.2498%;\"\u003eC-Bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 43.4658%;\"\u003e\u003cstrong\u003eCommunication Speed\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.2498%;\"\u003e9,600 bit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 43.4658%;\"\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.2498%;\"\u003eHVAC \/ Building Automation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 43.4658%;\"\u003e\u003cstrong\u003eCompatible Systems\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.2498%;\"\u003eExcel 500 \/ Excel 100 \/ Excel 5000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 43.4658%;\"\u003e\u003cstrong\u003eCompatible Controllers\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.2498%;\"\u003eXC 5010B, XC 6010, XL 100B, XM 100A D1, XPC 500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 43.4658%;\"\u003e\u003cstrong\u003eFirmware EPROM\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.2498%;\"\u003eXDE 505\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 43.4658%;\"\u003e\u003cstrong\u003eEPROM Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.2498%;\"\u003e512 kbit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 43.4658%;\"\u003e\u003cstrong\u003eInstallation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.2498%;\"\u003ePlug-In PCB Submodule\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 43.4658%;\"\u003e\u003cstrong\u003eAuxiliary Switches\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.2498%;\"\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 43.4658%;\"\u003e\u003cstrong\u003eDrive Shaft Diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.2498%;\"\u003e10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 43.4658%;\"\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.2498%;\"\u003e9 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 43.4658%;\"\u003e\u003cstrong\u003eProtection Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.2498%;\"\u003eIP54\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 43.4658%;\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.2498%;\"\u003e-20°C to +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 43.4658%;\"\u003e\u003cstrong\u003eMounting Position\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.2498%;\"\u003eOptional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 43.4658%;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.2498%;\"\u003e0.22 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eInformation About XD-505A\u003c\/h4\u003e\n\u003cp dir=\"auto\" data-start=\"402\" data-end=\"876\" class=\"PDq2pG_selectionAnchorContainer\"\u003eThe XD-505A is a Honeywell C-Bus communication submodule used to provide HVAC controller communication functionality. Honeywell documentation identifies it as the standard C-Bus communications submodule, with a communication rate of 9,600 baud. The module is installed directly onto the controller PCB and contains its own XDE 505 firmware EPROM. It is associated with Honeywell Excel 500\/100 and Excel 5000 building automation systems. \u003cspan class=\"contents\" data-content-reference-start=\"835\" data-content-reference-end=\"868\"\u003e\u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1291\" data-end=\"2127\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"703\" data-end=\"1384\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"730\" data-end=\"1339\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1105\" data-end=\"1892\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1027\" data-end=\"1844\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"1022\" data-end=\"1720\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"964\" data-end=\"1745\"\u003e\u003c\/ul\u003e\n\u003cul data-start=\"895\" data-end=\"1639\"\u003e\n\u003cli data-section-id=\"wo3m72\" data-start=\"895\" data-end=\"1001\"\u003eC-Bus Communication: Provides communication between compatible Honeywell controllers and C-Bus networks.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"hj85fw\" data-start=\"1002\" data-end=\"1065\"\u003e9,600 Baud Rate: Supports C-Bus communication at 9,600 bit\/s.\u003c\/li\u003e\n\u003cli data-section-id=\"l3hwn6\" data-start=\"1066\" data-end=\"1149\"\u003ePlug-In Submodule: Installs directly onto compatible Honeywell controller boards.\u003c\/li\u003e\n\u003cli data-section-id=\"1vp6gcl\" data-start=\"1150\" data-end=\"1240\"\u003eExcel 5000 Compatibility: Designed for use with Honeywell Excel 5000-series controllers.\u003c\/li\u003e\n\u003cli data-section-id=\"o1dy33\" data-start=\"1241\" data-end=\"1317\"\u003eXDE 505 Firmware: Uses an XDE 505 EPROM containing the submodule software.\u003c\/li\u003e\n\u003cli data-section-id=\"1bnrs0c\" data-start=\"1318\" data-end=\"1423\"\u003eCompact Module: Provides communication functionality without requiring a separate controller enclosure.\u003c\/li\u003e\n\u003cli data-section-id=\"czj5g0\" data-start=\"1424\" data-end=\"1524\"\u003eHVAC Communication: Supports communication functions within Honeywell building automation systems.\u003c\/li\u003e\n\u003cli data-section-id=\"ppj7ti\" data-start=\"1525\" data-end=\"1639\"\u003eRetrofit Application: Can be used as a communications submodule or replacement component for compatible systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"auto\" data-start=\"1641\" data-end=\"1813\"\u003eThe XD-505A provides the communication interface required for compatible Honeywell Excel building automation and HVAC control systems.\u003c\/p\u003e\n\u003cp id=\"p-rc_c7b8f4fae39e183e-25\"\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52782930952490,"sku":"XD-505A","price":1959.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/6752cbea3a964ba59b68cd649bf789f2.jpg?v=1790584551","url":"https:\/\/iqelectro.com\/products\/honeywell-xd-505a-c-bus-communication-submodule-for-excel-5000-controllers","provider":"IQElectro","version":"1.0","type":"link"}