{"product_id":"ifm-electronic-ac1402-as-i-profinet-gateway-dual-master-industrial-controller","title":"IFM Electronic AC1402 AS-i PROFINET Gateway Dual Master Industrial Controller","description":"\u003ch4 class=\"PDq2pG_selectionAnchorContainer\"\u003eDescription\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp dir=\"ltr\" data-path-to-node=\"19,0,0\"\u003eThe IFM Electronic AC1402 is an AS-Interface (AS-i) PROFINET Gateway with two integrated AS-i masters, designed to connect field-level sensors and actuators to higher-level industrial automation systems. It enables communication between AS-i networks and PROFINET controllers, supporting reliable data exchange, configuration, and diagnostics. The gateway features an integrated color display, Ethernet interfaces, and a robust housing for DIN rail installation.\u003c\/p\u003e\n\u003cp dir=\"ltr\" data-path-to-node=\"19,0,0\"\u003e \u003c\/p\u003e\n\u003cp dir=\"ltr\" data-path-to-node=\"19,0,0\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable style=\"border-collapse: collapse; width: 443px; max-width: 100%; font-size: 14px; height: 544px;\" height=\"575\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"padding: 3px 6px; width: 197.5px; height: 19.5938px;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 3px 6px; width: 219.5px; height: 19.5938px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"padding: 3px 6px; width: 197.5px; height: 19.5938px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 3px 6px; width: 219.5px; height: 19.5938px;\"\u003eIFM Electronic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"padding: 3px 6px; width: 197.5px; height: 19.5938px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 3px 6px; width: 219.5px; height: 19.5938px;\"\u003eAC1402\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"padding: 3px 6px; width: 197.5px; height: 19.5938px;\"\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 3px 6px; width: 219.5px; height: 19.5938px;\"\u003eAS-i PROFINET Gateway\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"padding: 3px 6px; width: 197.5px; height: 19.5938px;\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 3px 6px; width: 219.5px; height: 19.5938px;\"\u003eAS-i Gateway 2Master PN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"padding: 3px 6px; width: 197.5px; height: 19.5938px;\"\u003e\u003cstrong\u003eNumber of AS-i Masters\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 3px 6px; width: 219.5px; height: 19.5938px;\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"padding: 3px 6px; width: 197.5px; height: 19.5938px;\"\u003e\u003cstrong\u003eMaster Profile\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 3px 6px; width: 219.5px; height: 19.5938px;\"\u003eM4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"padding: 3px 6px; width: 197.5px; height: 19.5938px;\"\u003e\u003cstrong\u003eFieldbus Protocol\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 3px 6px; width: 219.5px; height: 19.5938px;\"\u003ePROFINET RT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"padding: 3px 6px; width: 197.5px; height: 19.5938px;\"\u003e\u003cstrong\u003ePROFINET Device Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 3px 6px; width: 219.5px; height: 19.5938px;\"\u003eClass B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"padding: 3px 6px; width: 197.5px; height: 19.5938px;\"\u003e\u003cstrong\u003eCommunication Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 3px 6px; width: 219.5px; height: 19.5938px;\"\u003eEthernet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"padding: 3px 6px; width: 197.5px; height: 19.5938px;\"\u003e\u003cstrong\u003eEthernet Ports\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 3px 6px; width: 219.5px; height: 19.5938px;\"\u003e2 × RJ45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"padding: 3px 6px; width: 197.5px; height: 19.5938px;\"\u003e\u003cstrong\u003eConfiguration Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 3px 6px; width: 219.5px; height: 19.5938px;\"\u003eEthernet \/ Web Interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"padding: 3px 6px; width: 197.5px; height: 19.5938px;\"\u003e\u003cstrong\u003eAdditional Protocols\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 3px 6px; width: 219.5px; height: 19.5938px;\"\u003eTCP\/IP, UDP\/IP, Modbus TCP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"padding: 3px 6px; width: 197.5px; height: 19.5938px;\"\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 3px 6px; width: 219.5px; height: 19.5938px;\"\u003e18–32 V DC (AUX)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"padding: 3px 6px; width: 197.5px; height: 19.5938px;\"\u003e\u003cstrong\u003eAS-i Supply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 3px 6px; width: 219.5px; height: 19.5938px;\"\u003e21–31.6 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"padding: 3px 6px; width: 197.5px; height: 19.5938px;\"\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 3px 6px; width: 219.5px; height: 19.5938px;\"\u003eFull-Graphic Color LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"padding: 3px 6px; width: 197.5px; height: 19.5938px;\"\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 3px 6px; width: 219.5px; height: 19.5938px;\"\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"padding: 3px 6px; width: 197.5px; height: 19.5938px;\"\u003e\u003cstrong\u003eProtection Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 3px 6px; width: 219.5px; height: 19.5938px;\"\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"padding: 3px 6px; width: 197.5px; height: 19.5938px;\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 3px 6px; width: 219.5px; height: 19.5938px;\"\u003e0°C to 60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"padding: 3px 6px; width: 197.5px; height: 19.5938px;\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 3px 6px; width: 219.5px; height: 19.5938px;\"\u003e135.5 × 93 × 106.2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"padding: 3px 6px; width: 197.5px; height: 19.5938px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 3px 6px; width: 219.5px; height: 19.5938px;\"\u003e719 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4\u003eInformation About AC1402\u003c\/h4\u003e\n\u003cp dir=\"ltr\" data-path-to-node=\"19,1,0\"\u003eThe AC1402 is an IFM Electronic AS-i Gateway 2Master PN designed for industrial communication and distributed automation applications. It incorporates two AS-i masters with an M4 profile and a PROFINET RT Device Class B interface. The device includes an Ethernet configuration interface with a web-based interface for configuration, diagnostics, and remote maintenance. Its integrated color LCD display provides operating information and status indications for connected AS-i networks.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003cstrong\u003e:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003eDual AS-i Masters: Features two integrated AS-Interface masters, allowing connection and management of two separate AS-i networks through one gateway.\u003c\/li\u003e\n\u003cli\u003ePROFINET Communication: Provides a PROFINET RT Device Class B interface for transferring field-level data to higher-level PLC and industrial control systems.\u003c\/li\u003e\n\u003cli\u003eIntegrated Ethernet Switch: Includes two RJ45 PROFINET ports, supporting network connectivity and convenient integration into industrial Ethernet installations.\u003c\/li\u003e\n\u003cli\u003eWeb-Based Configuration: Provides an Ethernet configuration interface with a dynamic web interface for device setup, monitoring, diagnostics, and remote maintenance.\u003c\/li\u003e\n\u003cli\u003eColor LCD Display: Features a full-graphic color display for viewing device information, network conditions, and the operating status of connected AS-i devices.\u003c\/li\u003e\n\u003cli\u003eFlexible Power Supply: Supports device power through an auxiliary 24 V supply or through AS-i Bus 1, depending on the installation configuration.\u003c\/li\u003e\n\u003cli\u003eCODESYS Compatibility: Supports an optional CODESYS V3 license, enabling additional programmable control functionality.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe AC1402 delivers reliable communication between AS-i field devices and PROFINET automation networks for industrial control, monitoring, and distributed I\/O applications.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003c\/span\u003e\u003cspan class=\"citation-409 citation-end-409\"\u003e\u003csup class=\"superscript\" data-turn-source-index=\"15\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp id=\"p-rc_c7b8f4fae39e183e-25\"\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"IFM Electronic","offers":[{"title":"Default Title","offer_id":53625168429354,"sku":"AC1402","price":1939.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/s-l1600_9b5802c8-2b2b-42ae-9cad-15e455f4d68d.webp?v=1794852723","url":"https:\/\/iqelectro.com\/products\/ifm-electronic-ac1402-as-i-profinet-gateway-dual-master-industrial-controller","provider":"IQElectro","version":"1.0","type":"link"}