{"product_id":"jla36225-schneider-electric-225a-3-pole-600v-i-line-molded-case-circuit-breaker","title":"JLA36225 | Schneider Electric 225A 3-Pole 600V I-Line Molded Case Circuit Breaker","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-end=\"474\" data-start=\"21\"\u003e\u003cmeta charset=\"utf-8\"\u003eThe Schneider Electric JLA36225 is a 3-pole molded case circuit breaker engineered for protection of three-phase electrical systems at up to 600 V. The part number JLA36225 operates at a 225 A current rating and provides thermal magnetic trip functionality to safeguard circuits against overloads and short circuits. It is suited for industrial and commercial power distribution where dependable fault interruption is required.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003cstrong\u003eCondition\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cmeta charset=\"utf-8\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCircuit Breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eJLA36225\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmperage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e225 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterrupt Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 kA @ 600 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrame Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eJ Frame\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eI-Line Plug-In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandards \u0026amp; Certifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL 489, CSA C22.2 No. 5, IEC 60947-2, CE, NOM, CCC, RoHS, REACH, UKCA, California Prop 65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25 to 70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eActuator Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eToggle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6.07 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About \u003cmeta charset=\"utf-8\"\u003e\n\u003cspan data-sheets-root=\"1\"\u003eJLA36225\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp data-end=\"1065\" data-start=\"503\"\u003e\u003cmeta charset=\"utf-8\"\u003eThe JLA36225 is part of Schneider Electric’s PowerPact J-Frame molded case circuit breaker family, designed for robust circuit protection and integration into I-Line distribution systems. It features a thermomagnetic trip unit with long-time and instantaneous protection functions for coordinated response to overcurrent and fault conditions. Its I-Line plug-in construction and toggle actuator enable secure mounting and serviceability with compatible panels. This breaker is typically used in industrial, commercial, and infrastructure power distribution to enhance electrical safety and reliability.\u003c\/p\u003e\n\u003ch3 data-end=\"1088\" data-start=\"1067\"\u003e\u003cbr\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong data-end=\"1102\" data-start=\"1085\"\u003eKey Features:\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e225 A current rating: Supports moderate to high current loads in three-phase systems.\u003c\/li\u003e\n\u003cli\u003eThermal magnetic trip unit: Combines overload and short-circuit protection in one mechanism.\u003c\/li\u003e\n\u003cli\u003eI-Line connection: Plug-in design for compatible panelboard integration.\u003c\/li\u003e\n\u003cli\u003e600 VAC capability: Rated for operation up to 600 V AC.\u003c\/li\u003e\n\u003cli\u003e50 kA interrupt rating @ 600 V: Safely interrupts significant fault currents.\u003c\/li\u003e\n\u003cli\u003eJ-Frame construction: PowerPact J-Frame platform for durable performance.\u003c\/li\u003e\n\u003cli\u003e3-pole configuration: Ensures balanced phase protection in 3-phase systems.\u003c\/li\u003e\n\u003cli\u003eToggle actuator: Manual ON\/OFF operation with clear position indication.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe JLA36225 delivers the reliability and precision required for dependable molded case circuit protection in industrial and commercial power systems.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":51064636113194,"sku":"JLA36225","price":2899.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/s-l1600_e1d5bcd5-57ec-4f4a-9f9a-1fdeb5acd927.webp?v=1768847199","url":"https:\/\/iqelectro.com\/products\/jla36225-schneider-electric-225a-3-pole-600v-i-line-molded-case-circuit-breaker","provider":"IQElectro","version":"1.0","type":"link"}