{"product_id":"johnson-controls-g67ag-3-intermittent-pilot-ignition-control-with-spark-ignition-and-flame-monitoring","title":"Johnson Controls G67AG-3 Intermittent Pilot Ignition Control With Spark Ignition and Flame Monitoring","description":"\u003ch4 class=\"PDq2pG_selectionAnchorContainer\"\u003eDescription\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eThe Johnson Controls G67AG-3 is an intermittent pilot ignition control for compatible gas-fired heating equipment. It uses high-voltage spark ignition to light the pilot and permits main burner operation after the pilot flame is detected.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cbr\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable style=\"width: 100.044%; height: 509.618px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 29.7018%; height: 19.6007px;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.7593%; height: 19.6007px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 29.7018%; height: 19.6007px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.7593%; height: 19.6007px;\"\u003eJohnson Controls\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 29.7018%; height: 19.6007px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.7593%; height: 19.6007px;\"\u003eHVAC Controls\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 29.7018%; height: 19.6007px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.7593%; height: 19.6007px;\"\u003eG67AG-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 29.7018%; height: 19.6007px;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.7593%; height: 19.6007px;\"\u003eIgnition Control Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 29.7018%; height: 19.6007px;\"\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.7593%; height: 19.6007px;\"\u003eG67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 29.7018%; height: 19.6007px;\"\u003e\u003cstrong\u003eIgnition System\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.7593%; height: 19.6007px;\"\u003eIntermittent pilot; indirect ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 29.7018%; height: 19.6007px;\"\u003e\u003cstrong\u003eControl Construction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.7593%; height: 19.6007px;\"\u003eSolid-state, self-checking\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 29.7018%; height: 19.6007px;\"\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.7593%; height: 19.6007px;\"\u003e24 VAC nominal, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2014px;\"\u003e\n\u003ctd style=\"width: 29.7018%; height: 39.2014px;\"\u003e\u003cstrong\u003eNominal Operating Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.7593%; height: 39.2014px;\"\u003e0.15 A plus connected gas valve loads\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 29.7018%; height: 19.6007px;\"\u003e\u003cstrong\u003eIgnition Source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.7593%; height: 19.6007px;\"\u003eHigh-voltage spark, capacitive discharge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 29.7018%; height: 19.6007px;\"\u003e\u003cstrong\u003eFlame Detection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.7593%; height: 19.6007px;\"\u003eFlame rectification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2014px;\"\u003e\n\u003ctd style=\"width: 29.7018%; height: 39.2014px;\"\u003e\u003cstrong\u003eMinimum Flame Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.7593%; height: 39.2014px;\"\u003e0.2 microampere\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2014px;\"\u003e\n\u003ctd style=\"width: 29.7018%; height: 39.2014px;\"\u003e\u003cstrong\u003eFlame Failure Response\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.7593%; height: 39.2014px;\"\u003e0.8 second maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2014px;\"\u003e\n\u003ctd style=\"width: 29.7018%; height: 39.2014px;\"\u003e\u003cstrong\u003eIgnition Trial\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.7593%; height: 39.2014px;\"\u003eContinuous while heat demand remains; non-100% lockout design\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 29.7018%; height: 19.6007px;\"\u003e\u003cstrong\u003eNominal Spark Gap\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.7593%; height: 19.6007px;\"\u003e0.1 inch \/ approximately 2.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2014px;\"\u003e\n\u003ctd style=\"width: 29.7018%; height: 39.2014px;\"\u003e\u003cstrong\u003eGas Valve Contact Ratings\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.7593%; height: 39.2014px;\"\u003ePilot and main valve: each 2 A continuous, 5 A inrush\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2014px;\"\u003e\n\u003ctd style=\"width: 29.7018%; height: 39.2014px;\"\u003e\u003cstrong\u003eOperating Environment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.7593%; height: 39.2014px;\"\u003e−40 to 150°F \/ −40 to 66°C; maximum 95% relative humidity, noncondensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 29.7018%; height: 19.6007px;\"\u003e\u003cstrong\u003eLifecycle Status\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.7593%; height: 19.6007px;\"\u003eDiscontinued by manufacturer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 29.7018%; height: 19.6007px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.7593%; height: 19.6007px;\"\u003e0.25 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eInformation About G67AG-3\u003c\/h4\u003e\n\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003e\u003cmeta charset=\"utf-8\"\u003eThe G67AG-3 is a self-checking model in the Johnson Controls G67 ignition control family. Its solid-state circuitry integrates spark generation, flame monitoring, and pilot and main gas valve control. It operates with a compatible thermostat, pilot burner, flame sensor, and redundant main gas valve arrangement. The control uses flame rectification to verify combustion and responds to flame loss by de-energizing the main valve and restarting the ignition sequence.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eIntermittent pilot operation: Energizes the pilot during a heating demand and shuts it off when the demand ends.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSpark ignition: Uses capacitive-discharge high-voltage spark to ignite the pilot burner.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFlame verification: Uses flame rectification before permitting main gas valve operation.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFlame-loss response: De-energizes the main valve within a maximum of 0.8 second after loss of proven flame.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eContinuous ignition trial: Continues attempting pilot ignition while the thermostat calls for heat.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLow-voltage supply: Operates from nominal 24 VAC power at 50\/60 Hz.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAmbient capability: Supports operating temperatures from −40 to 150°F.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSpecified spark gap: Uses a nominal electrode gap of 0.1 inch.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eThe G67AG-3 delivers the reliability and precision required for coordinated pilot ignition and flame supervision in compatible gas heating systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp id=\"p-rc_c7b8f4fae39e183e-25\"\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Johnson Controls","offers":[{"title":"Default Title","offer_id":53353904079146,"sku":"G67AG-3","price":999.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/s-l1600_4794c3cc-e887-4f1b-b711-dc5f41e44e9f.webp?v=1793179404","url":"https:\/\/iqelectro.com\/products\/johnson-controls-g67ag-3-intermittent-pilot-ignition-control-with-spark-ignition-and-flame-monitoring","provider":"IQElectro","version":"1.0","type":"link"}