{"product_id":"keyence-fd-xa1-din-rail-flow-sensor-controller-for-industrial-automation","title":"Keyence FD-XA1 DIN Rail Flow Sensor Controller for Industrial Automation","description":"\u003ch4 class=\"PDq2pG_selectionAnchorContainer\"\u003eDescription\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe Keyence FD-XA1 is a DIN rail-mounted controller designed for use with the FD-X series clamp-on micro flow sensors. It processes flow measurement data, displays instantaneous and accumulated flow values, and provides configurable outputs for industrial process monitoring, liquid dispensing, and automated flow control.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable height=\"657\" style=\"width: 92.1454%;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 40.6268%;\"\u003e\u003cstrong\u003e\u003cspan\u003eCondition\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.0775%;\"\u003e\u003cspan\u003eNew\/Never Used Surplus\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 40.6268%;\"\u003e\u003cstrong\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.0775%;\"\u003e\u003cspan\u003eKeyence\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 40.6268%;\"\u003e\u003cstrong\u003e\u003cspan\u003eCategory\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.0775%;\"\u003e\u003cspan\u003eFlow Measurement\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 40.6268%;\"\u003e\u003cstrong\u003e\u003cspan\u003ePart Number\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.0775%;\"\u003e\u003cspan\u003eFD-XA1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 40.6268%;\"\u003e\u003cstrong\u003e\u003cspan\u003eSubcategory\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.0775%;\"\u003e\u003cspan\u003eFlow Sensor Controllers\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 40.6268%;\"\u003e\u003cstrong\u003e\u003cspan\u003eController Type\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.0775%;\"\u003e\u003cspan\u003eDIN rail-mounted main unit\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 40.6268%;\"\u003e\u003cstrong\u003e\u003cspan\u003eDisplay\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.0775%;\"\u003e\u003cspan\u003e4-digit LED, OLED, status indicators\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 40.6268%;\"\u003e\u003cstrong\u003e\u003cspan\u003eResponse Time\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.0775%;\"\u003e\u003cspan\u003e50 ms–60 s\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 40.6268%;\"\u003e\u003cstrong\u003e\u003cspan\u003eDetection Modes\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.0775%;\"\u003e\u003cspan\u003eFlow, area, pulse, accumulation, shot\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 40.6268%;\"\u003e\u003cstrong\u003e\u003cspan\u003eOutput Type\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.0775%;\"\u003e\u003cspan\u003eNPN\/PNP open collector\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 40.6268%;\"\u003e\u003cstrong\u003e\u003cspan\u003eAnalog Output\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.0775%;\"\u003e\u003cspan\u003e4–20 mA or 0–20 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 40.6268%;\"\u003e\u003cstrong\u003e\u003cspan\u003eMax. Output Voltage\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.0775%;\"\u003e\u003cspan\u003e30 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 40.6268%;\"\u003e\u003cstrong\u003e\u003cspan\u003eMax. Output Current\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.0775%;\"\u003e\u003cspan\u003e50 mA\/channel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 40.6268%;\"\u003e\u003cstrong\u003e\u003cspan\u003ePower Supply\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.0775%;\"\u003e\u003cspan\u003e20–30 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 40.6268%;\"\u003e\u003cstrong\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.0775%;\"\u003e\u003cspan\u003e195 mA max., excluding load\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 40.6268%;\"\u003e\u003cstrong\u003e\u003cspan\u003eCommunication\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.0775%;\"\u003e\u003cspan\u003eIO-Link v1.1, COM2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 40.6268%;\"\u003e\u003cstrong\u003e\u003cspan\u003eExpansion Capacity\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.0775%;\"\u003e\u003cspan\u003eUp to 7 units\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 40.6268%;\"\u003e\u003cstrong\u003e\u003cspan\u003eMemory\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.0775%;\"\u003e\u003cspan\u003eEEPROM\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 40.6268%;\"\u003e\u003cstrong\u003e\u003cspan\u003eStorage Interval\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.0775%;\"\u003e\u003cspan\u003eEvery 10 seconds\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 40.6268%;\"\u003e\u003cstrong\u003e\u003cspan\u003eUSB Interface\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.0775%;\"\u003e\u003cspan\u003eUSB 2.0\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 40.6268%;\"\u003e\u003cstrong\u003e\u003cspan\u003eOperating Temperature\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.0775%;\"\u003e\u003cspan\u003e-10 to +50°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 40.6268%;\"\u003e\u003cstrong\u003e\u003cspan\u003eHumidity\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.0775%;\"\u003e\u003cspan\u003e35–85% RH, non-condensing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 40.6268%;\"\u003e\u003cstrong\u003e\u003cspan\u003eProtection\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.0775%;\"\u003e\u003cspan\u003eReverse polarity, surge, short circuit\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 40.6268%;\"\u003e\u003cstrong\u003e\u003cspan\u003eHousing Material\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.0775%;\"\u003e\u003cspan\u003ePolycarbonate; POM keys\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 40.6268%;\"\u003e\u003cstrong\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.0775%;\"\u003e\u003cspan\u003e 210 g\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4\u003eInformation About FD-XA1\u003c\/h4\u003e\n\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003e\u003cmeta charset=\"utf-8\"\u003eThe FD-XA1 is the main controller unit in the Keyence FD-X series, designed to receive measurement signals from compatible sensor heads and convert them into usable monitoring and control data. Its display system combines a four-digit seven-segment display, an OLED display, output indicators, and stability-level information for operational monitoring. The controller supports selectable NPN or PNP outputs, analog current signals, and IO-Link communication for integration with industrial automation equipment. Its configurable detection modes, stored measurement data, and support for up to seven expansion units allow it to accommodate different flow monitoring and dispensing applications.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003eDIN Rail Mounting: Main controller unit designed for installation on a standard DIN rail.\u003c\/li\u003e\n\u003cli\u003eMulti-Format Display: Combines a four-digit display, OLED screen, output indicators, and stability-level indication.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eConfigurable Detection Modes: Supports instantaneous flow, area, pulse, accumulated flow, and shot measurement modes.\u003c\/li\u003e\n\u003cli\u003eFlexible Outputs: Selectable NPN\/PNP open-collector outputs and configurable analog current output.\u003c\/li\u003e\n\u003cli\u003eIO-Link Communication: Supports IO-Link v1.1, COM2 at 38.4 kbps.\u003c\/li\u003e\n\u003cli\u003eAdjustable Response Time: Selectable response times from 50 ms to 60 seconds.\u003c\/li\u003e\n\u003cli\u003eData Retention: EEPROM stores accumulated measurement data, with a specified retention period exceeding 10 years.\u003c\/li\u003e\n\u003cli\u003eExpandable Configuration: Supports up to seven expansion units per main controller.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe FD-XA1 delivers the reliability and precision required for industrial flow monitoring, liquid dispensing, and automated process control.\u003c\/p\u003e\n\u003cp id=\"p-rc_c7b8f4fae39e183e-25\"\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Keyence","offers":[{"title":"Default Title","offer_id":52920059560234,"sku":"FD-XA1","price":465.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/8c6b3a8a77d14ab4a2fbba7a962a5fe7.jpg?v=1791818258","url":"https:\/\/iqelectro.com\/products\/keyence-fd-xa1-din-rail-flow-sensor-controller-for-industrial-automation","provider":"IQElectro","version":"1.0","type":"link"}