{"product_id":"keyence-fd-xa5-flow-sensor-controller-unit-reliable-delivery","title":"FD-XA5 | Keyence FD-X Series Flow Sensor Controller, Panel-Mount Main Unit","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-start=\"144\" data-end=\"396\"\u003eThe Keyence FD-XA5 is a panel-mount main control unit designed for use with the FD-X Series clamp-on flow sensors. This digital flow controller provides precise monitoring and control of instantaneous and accumulated flow rates in various liquids, including water, oils, and chemicals—without direct pipe contact. Featuring a bright 4-digit 7-segment OLED display, the FD-XA5 offers clear visual feedback, fast response times, and compatibility with IO-Link for advanced data communication in smart factory environments.\u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eKeyence\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eControls \u0026amp; Indicators\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFD-XA5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eControl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePanel-Mount Main Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4-digit 7-segment OLED display with stability level indicator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay Refresh Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInstantaneous flow rate: 5 times\/sec; Discharge\/Accumulated flow: 30 times\/sec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResponse Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSelectable: 50 ms \/ 100 ms \/ 500 ms \/ 1 s \/ 2.5 s \/ 5 s \/ 10 s \/ 30 s \/ 60 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMemory Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEEPROM (10+ years data retention, 1M+ rewrite cycles)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChannels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 (CH1 and CH2 selectable modes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDetection Modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInstantaneous flow rate, Area mode, Pulse output (+\/−), Integrated flow, Shot mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNPN\/PNP selectable open collector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 VDC or less, max 50 mA per channel (20 mA per expansion channel)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAnalog Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4–20 mA or 0–20 mA (selectable), load resistance ≤ 500 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExternal Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eZero input, shot sampling input, flow reset input, zero shift input (selectable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort Circuit Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNPN ≤ 1 mA \/ PNP ≤ 2 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20–30 VDC (Class 2), ripple ≤ 10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e195 mA or less (excluding load)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNetwork Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIO-Link supported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Circuit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eReverse polarity, surge, and short-circuit protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePanel mount (front face IP50 equivalent; rear section IP20)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e−10°C to +50°C (14°F to 122°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e−25°C to +60°C (−13°F to 140°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35%–85% RH (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVibration Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10–55 Hz, double amplitude 1.5 mm (0.06\"), 2 h in each X\/Y\/Z axis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShock Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 m\/s² (10 G), 16 ms pulse, 1000 times each axis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaterial\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMain body: PC; Key top: POM; Cable: PVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePanel mount (screw or clip type)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterface Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTerminal block connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApprox. 0.46 lbs (210 g)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About \u003cspan data-sheets-root=\"1\"\u003eFD-XA5\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe FD-XA5 serves as the main unit controller in Keyence’s FD-X Series of clamp-on flow sensors. It integrates digital control, analog output, and diagnostic functions for up to two sensor channels. The device supports multiple operating modes—instantaneous flow rate, area mode, pulse output, and integrated flow mode—allowing for versatile flow monitoring. With EEPROM-based memory backup, the FD-XA5 ensures long-term data retention (over 10 years). Engineered for robust industrial use, it includes surge protection, reverse polarity protection, and short-circuit protection, guaranteeing stable performance even in demanding environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePanel-Mount Design: Compact main unit designed for integration into control panels.\u003c\/li\u003e\n\u003cli\u003e4-Digit OLED Display: High-contrast, easy-to-read output with stability indicators.\u003c\/li\u003e\n\u003cli\u003eDual Channel Capability: Supports two independent flow sensor inputs.\u003c\/li\u003e\n\u003cli\u003eSelectable Modes: Instantaneous flow, area mode, integrated flow, and shot mode.\u003c\/li\u003e\n\u003cli\u003eHigh-Speed Response: 50 ms to 60 s response time, user selectable.\u003c\/li\u003e\n\u003cli\u003eAnalog and Digital Outputs: Includes 4–20 mA\/0–20 mA output and NPN\/PNP open collector outputs.\u003c\/li\u003e\n\u003cli\u003eIO-Link Support: Enables digital data exchange and remote diagnostics for Industry 4.0 systems.\u003c\/li\u003e\n\u003cli\u003eEEPROM Data Storage: Retains configuration and accumulated flow data for over 10 years.\u003c\/li\u003e\n\u003cli\u003eComprehensive Protection: Reverse polarity, surge, and short-circuit protection built-in.\u003c\/li\u003e\n\u003cli\u003eEnvironmental Durability: Wide operating temperature range and vibration resistance for factory environments.\u003c\/li\u003e\n\u003cli\u003eCompact and Lightweight: Easy installation and minimal panel space requirements.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe FD-XA5 delivers precision monitoring and digital connectivity in a compact, reliable industrial controller.\u003c\/p\u003e","brand":"Keyence","offers":[{"title":"Default Title","offer_id":50748260679978,"sku":"FD-XA5","price":875.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0392\/4266\/files\/2025-10-27150144.png?v=1761570118","url":"https:\/\/iqelectro.com\/products\/keyence-fd-xa5-flow-sensor-controller-unit-reliable-delivery","provider":"IQElectro","version":"1.0","type":"link"}